1SDA073283R1 ABB E6.2V 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker 6300 A

1SDA073283R1 ABB E6.2V 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker 6300 A

ABB 1SDA073283R1 E6.2V 6300 Ekip Dip LSIG 4p WMP is a 6300 A four-pole withdrawable SACE Emax 2 air circuit breaker with Ekip Dip LSIG electronic protection and up to 150 kA breaking capacity for high-current low-voltage power distribution systems.

SKU: 1SDA073283R1MPN: 1SDA073283R1
Price
List Price £66,284.27 ex VAT
Your Price (ex VAT) Save 25%
£49,713.20 25% OFF
You save £16,571.07 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £49,713.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£49,713.20

Why Choose the ABB E6.2V 6300 Ekip Dip LSIG 4p WMP Air Circuit Breaker?

The ABB E6.2V 6300 Ekip Dip LSIG 4p WMP, order code 1SDA073283R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in very high-current low-voltage power distribution systems. With a rated uninterrupted current of 6300 A, it combines the large E6.2 frame and V performance level with an Ekip Dip LSIG electronic protection release.

The Ekip Dip LSIG release provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection. Protection thresholds are configured using DIP switches, providing straightforward adjustment while supporting selective coordination and comprehensive fault protection in demanding electrical distribution networks.

The E6.2V performance level provides a rated ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC, 130 kA at 500/525 V AC and 100 kA at 690 V AC. This four-pole model is supplied as a withdrawable moving part, supporting efficient isolation, inspection and maintenance within compatible ABB SACE Emax 2 switchgear assemblies.

Key Advantages

  • Very high-current 6300 A four-pole air circuit breaker for demanding low-voltage distribution systems.
  • Ekip Dip LSIG electronic trip unit provides overload, short-time, instantaneous and ground-fault protection.
  • Adjustable short-time protection supports selective coordination between protective devices.
  • Exceptional rated ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC.
  • Maintains 100 kA Icu at 690 V AC for demanding high-power installations.
  • Withdrawable moving-part construction supports efficient switchgear isolation, servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E6.2 air circuit breaker platform.
  • 6300 A rated uninterrupted current.
  • Four-pole configuration.
  • V short-circuit performance level.
  • Ekip Dip LSIG electronic release.
  • Long-time overload, short-time selective, instantaneous and ground-fault protection.
  • Long-time protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Ground-fault protection adjustable from 0.1–1 × In.
  • Protection settings configured using DIP switches.
  • 150 kA Icu at 400/415/440 V AC.
  • 130 kA Icu at 500/525 V AC.
  • 100 kA Icu at 690 V AC.
  • Withdrawable moving-part design for compatible Emax 2 switchgear assemblies.

Comprehensive Protection for Very High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection for high-current low-voltage electrical installations. The E6.2 platform is engineered for major power distribution systems, combining a very high continuous current rating with exceptional short-circuit breaking performance for main switchboards, industrial plants, infrastructure and other critical electrical networks.

The Ekip Dip LSIG electronic trip unit combines adjustable long-time, short-time and instantaneous overcurrent protection with ground-fault protection. Together with the breaker’s 6300 A current rating, 150 kA breaking capacity at 400/415/440 V AC and withdrawable construction, this makes the E6.2V suitable for high-power installations requiring comprehensive fault protection, selective coordination and maintainability.

Typical Applications

  • Very high-current low-voltage main distribution switchboards.
  • Heavy industrial power distribution systems.
  • Power generation and utility distribution installations.
  • Data centres and critical infrastructure.
  • Large commercial and infrastructure electrical systems.
  • Transformer secondary and high-current distribution applications.
  • Incoming and outgoing switchgear feeders requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA073283R1
Product type Air circuit breaker
Frame / sub-type E6.2
Short-circuit performance level V
Rated current (In) 6300 A
Rated uninterrupted current (Iu) 6300 A
Number of poles 4
Release Ekip Dip LSIG
Release type Electronic
Protection functions Long-time, short-time selective, instantaneous and ground-fault protection (LSIG)
Long-time protection adjustment 0.4–1 × In
Instantaneous protection adjustment 1.5–15 × In
Ground-fault protection adjustment 0.1–1 × In
Protection adjustment method DIP switches
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 130 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Rated short-time withstand current (Icw) 100 kA
Current type AC
Version Withdrawable moving part
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073283R1 used for?

The ABB 1SDA073283R1 is a 6300 A four-pole air circuit breaker designed for switching and comprehensive protection in very high-current low-voltage industrial, infrastructure and critical power distribution systems.

What protection functions does the Ekip Dip LSIG release provide?

The Ekip Dip LSIG electronic release provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection.

What is the breaking capacity of the E6.2V 6300?

The E6.2V 6300 has a rated ultimate short-circuit breaking capacity of 150 kA at 400/415/440 V AC, 130 kA at 500/525 V AC and 100 kA at 690 V AC.

Does the ABB 1SDA073283R1 provide ground-fault protection?

Yes. Its Ekip Dip LSIG electronic release includes ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection, providing comprehensive protection for demanding distribution systems.

Is the ABB 1SDA073283R1 a fixed or withdrawable circuit breaker?

The E6.2V 6300 Ekip Dip LSIG 4p WMP is supplied as a withdrawable moving part for installation within compatible ABB SACE Emax 2 switchgear assemblies.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers are engineered for dependable protection, switching and control in critical low-voltage power distribution systems, combining very high current ratings and short-circuit performance with advanced electronic protection technology.