1SDA073276R1 ABB E6.2H 6300 Ekip Touch LSIG 4p WMP Air Circuit Breaker

1SDA073276R1 ABB E6.2H 6300 Ekip Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA073276R1 Emax 2 E6.2H 6300 is a 6300 A four-pole withdrawable air circuit breaker moving part with Ekip Touch LSIG electronic overload, short-circuit and earth-fault protection.

SKU: 1SDA073276R1MPN: 1SDA073276R1
Price
List Price £56,247.08 ex VAT
Your Price (ex VAT) Save 25%
£42,185.31 25% OFF
You save £14,061.77 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £42,185.31
Trade pricing is personalised to your account

Manufacturer Lead Time

£42,185.31

Why Choose the ABB E6.2H 6300 Ekip Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E6.2H 6300 Ekip Touch LSIG 4p WMP, order code 1SDA073276R1, is a high-current SACE Emax 2 air circuit breaker moving part designed for protection, switching and isolation in demanding low-voltage power-distribution systems. Part of the advanced ABB Emax 2 E6.2 series, this withdrawable four-pole breaker combines a 6300 A rated continuous current with H-level breaking performance and an intelligent Ekip Touch LSIG electronic protection release.

The integrated Ekip Touch LSIG trip unit provides long-time overload (L), selective short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. Protection settings are configured through the touch-sensitive display, with adjustable functions that allow the breaker to be coordinated with the requirements of high-current distribution circuits and other protective devices in the installation.

The E6.2H 6300 is rated for operation up to 690 V AC and provides an ultimate short-circuit breaking capacity of 100 kA throughout the 380–690 V AC range. Its withdrawable moving-part configuration interfaces with the corresponding Emax 2 fixed part, supporting efficient isolation and maintenance while four auxiliary contacts provide circuit-breaker open/closed status signalling.

Key Advantages

  • High-current 6300 A Emax 2 air circuit breaker for major low-voltage distribution systems.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • Ekip Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • High 100 kA ultimate breaking capacity across the specified 380–690 V AC operating range.
  • Integrated earth-fault protection enhances protection of distribution circuits and equipment.
  • Touch-sensitive interface simplifies protection configuration and monitoring.
  • Withdrawable moving-part construction supports efficient switchboard isolation, servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E6.2H series.
  • 6300 A rated continuous current.
  • 4-pole configuration.
  • Ekip Touch LSIG electronic protection release.
  • Long-time overload protection (L).
  • Selective short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • Long-time protection adjustment: 0.4–1 × In.
  • Short-time protection adjustment: 0.6–10 × In.
  • Instantaneous protection adjustment: 1.5–15 × In.
  • Earth-fault protection adjustment: 0.1–1 × In.
  • Rated operational voltage: 690 V AC.
  • Touch-sensitive display for protection configuration.
  • Withdrawable moving-part construction for use with the corresponding Emax 2 fixed part.

Reliable LSIG Protection for High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage distribution circuits against overloads, short circuits and earth faults. The Ekip Touch LSIG release continuously monitors circuit conditions and provides separate long-time, short-time, instantaneous and earth-fault protection functions, enabling comprehensive protection and selective coordination throughout the electrical distribution system.

The combination of a 6300 A current rating, 100 kA breaking capability, advanced electronic protection and withdrawable architecture makes the 1SDA073276R1 particularly suitable for large industrial and infrastructure switchboards. Its Ekip Touch interface simplifies protection configuration, while the withdrawable design supports inspection and servicing without permanently disturbing the switchboard's fixed main connections.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary protection and distribution.
  • Generator and power-generation distribution systems.
  • Manufacturing and process-industry switchboards.
  • Commercial and infrastructure electrical distribution.
  • Data centres and continuity-critical power systems.
  • High-current feeders requiring selective LSIG and earth-fault protection.

Technical Specifications

Series SACE Emax 2 E6.2
ABB order code 1SDA073276R1
Product type Air circuit breaker moving part
Performance level H
Rated continuous current (Iu) 6300 A
Number of poles 4
Trip unit Ekip Touch LSIG
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Long-time protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Ultimate breaking capacity (Icu) at 380 V AC 100 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 100 kA
Ultimate breaking capacity (Icu) at 440 V AC 100 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 100 kA
Ultimate breaking capacity (Icu) at 690 V AC 100 kA
Installation Withdrawable
Construction Moving part (WMP)
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073276R1?

The ABB 1SDA073276R1 is an Emax 2 E6.2H withdrawable air circuit breaker moving part rated at 6300 A, with four poles and an Ekip Touch LSIG electronic protection release.

What protection does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG provides long-time overload (L), selective short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection for comprehensive protection of high-current distribution circuits.

What is the breaking capacity of the ABB E6.2H 6300?

The E6.2H 6300 provides an ultimate short-circuit breaking capacity of 100 kA at rated operational voltages from 380 to 690 V AC.

Does the ABB 1SDA073276R1 include earth-fault protection?

Yes. The Ekip Touch LSIG release includes integrated earth-fault protection, with the G protection threshold adjustable to suit the protected distribution system.

Is the ABB 1SDA073276R1 fixed or withdrawable?

It is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part, supporting convenient isolation, inspection and maintenance.

Trusted Protection for Critical Power Distribution

ABB SACE Emax 2 air circuit breakers combine high-current switching, intelligent LSIG electronic protection and maintainable withdrawable construction to provide dependable protection and selective coordination for demanding low-voltage power-distribution systems.