1SDA073271R1 ABB E6.2H 6300 Ekip Dip LI 4p WMP Air Circuit Breaker

1SDA073271R1 ABB E6.2H 6300 Ekip Dip LI 4p WMP Air Circuit Breaker

ABB 1SDA073271R1 E6.2H 6300 Ekip Dip LI 4p WMP is a 6300 A four-pole withdrawable Emax 2 air circuit breaker moving part with Ekip Dip LI electronic overload and instantaneous short-circuit protection for high-current low-voltage distribution systems.

SKU: 1SDA073271R1MPN: 1SDA073271R1
Price
List Price £55,038.72 ex VAT
Your Price (ex VAT) Save 25%
£41,279.04 25% OFF
You save £13,759.68 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £41,279.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£41,279.04

Why Choose the ABB E6.2H 6300 Ekip Dip LI 4p WMP Air Circuit Breaker?

The ABB E6.2H 6300 Ekip Dip LI 4p WMP, order code 1SDA073271R1, is a high-performance four-pole air circuit breaker moving part from the ABB SACE Emax 2 range, designed for protection, switching and isolation in high-current low-voltage electrical distribution systems. With a rated current of 6300 A and an Ekip Dip LI solid-state electronic trip unit, it provides dependable long-time overload and instantaneous short-circuit protection for demanding industrial, commercial and infrastructure installations.

As part of the ABB Emax 2 E6.2H series, this breaker combines very high current capability with robust short-circuit performance and a withdrawable architecture. The moving part is designed for use with a compatible Emax 2 fixed chassis, allowing the breaker to be withdrawn for inspection and maintenance while supporting service continuity in critical electrical distribution systems.

The E6.2H 6300 has a rated current of 6300 A, a 690 V AC rated operational voltage and a 1000 V AC rated insulation voltage. Its H performance class provides a rated service short-circuit breaking capacity of 100 kA, while a 12 kV rated impulse withstand voltage supports reliable operation in demanding low-voltage switchgear applications.

Key Advantages

  • Very high-capacity 6300 A four-pole air circuit breaker for major low-voltage distribution systems.
  • Ekip Dip LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • 100 kA rated service short-circuit breaking capacity for high-fault-level installations.
  • 690 V AC rated operational voltage supports demanding industrial power networks.
  • Withdrawable moving-part design facilitates inspection, servicing and replacement.
  • Four change-over auxiliary contacts and open/closed circuit breaker position indication.
  • Robust mechanical endurance of 12,000 operating cycles.
  • Part of the proven ABB SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E6.2H air circuit breaker.
  • 6300 A rated current.
  • Four-pole (4P) configuration.
  • Ekip Dip LI solid-state electronic protection release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100 kA rated service short-circuit breaking capacity.
  • 12,000-cycle mechanical durability.
  • 2,000-cycle electrical durability at operating voltages up to 690 V AC.
  • Four change-over auxiliary contacts.
  • Open/closed circuit breaker position indication.
  • Withdrawable moving part (WMP) configuration.

High-Current Protection for Critical Power Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H provide switching, isolation and electrical protection for high-current low-voltage distribution systems. The combination of a 6300 A current rating and high short-circuit performance makes this breaker particularly suitable for main incomers, transformer secondary circuits, bus couplers and major feeders in large switchboards.

The Ekip Dip LI solid-state trip unit provides long-time protection against sustained overload conditions together with instantaneous protection against severe short circuits. Combined with the Emax 2 withdrawable architecture, the E6.2H 6300 provides a practical solution for installations requiring high current capacity, reliable protection and maintainable switchgear.

Typical Applications

  • Main incomers in high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • Transformer secondary protection.
  • Bus couplers and bus-tie circuit breaker applications.
  • Data centres and critical power infrastructure.
  • Large commercial buildings and infrastructure facilities.
  • Manufacturing plants and process industries.
  • Utility and energy distribution systems.
  • High-current switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
Frame / type E6.2H
Order code / MPN 1SDA073271R1
EAN 8015644771218
Product type Air circuit breaker moving part
Rated current (In) 6300 A
Number of poles 4P
Current type AC
Trip unit Ekip Dip LI
Protection functions L (long-time), I (instantaneous)
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated service short-circuit breaking capacity (Ics) 100 kA
Neutral pole current 50% of Iu
Mechanical durability 12,000 operating cycles
Mechanical operating frequency 60 cycles per hour
Electrical durability 2,000 operating cycles
Electrical operating frequency 10 cycles per hour
Power loss 1550 W
Connecting capacity 6000 mm²
Auxiliary contacts 4 change-over contacts
Control element Push button
Motor drive Optional
Main circuit connection Connection at separate chassis part
Protection rating IP30
Installation Withdrawable
Configuration Moving part (WMP)
Product net weight 134 kg

Frequently Asked Questions

What is the ABB 1SDA073271R1 used for?

The ABB 1SDA073271R1 is a 6300 A four-pole Emax 2 air circuit breaker moving part designed for protection, switching and isolation in high-current low-voltage electrical distribution systems.

What is the rated current of the E6.2H 6300 Ekip Dip LI?

The circuit breaker has a rated current of 6300 A, making it suitable for very high-current industrial, commercial and infrastructure power distribution applications.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI solid-state electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection.

What is the rated operational voltage of the ABB 1SDA073271R1?

The E6.2H 6300 has a rated operational voltage of 690 V AC and a rated insulation voltage of 1000 V AC.

Is the ABB 1SDA073271R1 a withdrawable circuit breaker?

Yes. The 1SDA073271R1 is the moving part of a withdrawable ABB Emax 2 air circuit breaker and connects through the appropriate separate Emax 2 chassis or fixed part.

Trusted Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high current capability, electronic circuit protection and a maintainable withdrawable architecture for demanding industrial, commercial and critical low-voltage power distribution applications.