1SDA073253R1 ABB E6.2V 5000 Ekip Dip LSIG 4p WMP Air Circuit Breaker

1SDA073253R1 ABB E6.2V 5000 Ekip Dip LSIG 4p WMP Air Circuit Breaker

ABB 1SDA073253R1 Emax 2 E6.2V 5000 is a 5000 A four-pole withdrawable air circuit breaker moving part with Ekip Dip LSIG electronic overload, short-circuit and earth-fault protection.

SKU: 1SDA073253R1MPN: 1SDA073253R1
Price
List Price £54,609.96 ex VAT
Your Price (ex VAT) Save 25%
£40,957.47 25% OFF
You save £13,652.49 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £40,957.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£40,957.47

Why Choose the ABB E6.2V 5000 Ekip Dip LSIG 4p WMP Air Circuit Breaker?

The ABB E6.2V 5000 Ekip Dip LSIG 4p WMP, order code 1SDA073253R1, is a high-performance SACE Emax 2 air circuit breaker moving part designed for protection and switching in demanding high-current low-voltage power-distribution systems. Part of the ABB Emax 2 E6.2 series, this withdrawable four-pole breaker combines a 5000 A rated current, V-level breaking performance and an Ekip Dip LSIG electronic protection release.

The integrated Ekip Dip LSIG trip unit provides long-time overload (L), selective short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. Its adjustable electronic protection functions enable the breaker to protect major distribution circuits while supporting selective coordination between upstream and downstream protective devices.

The E6.2V 5000 delivers an ultimate short-circuit breaking capacity of 150 kA at 400/415 V AC and 100 kA at 690 V AC. The withdrawable moving-part configuration interfaces with the corresponding Emax 2 fixed part, while four changeover auxiliary contacts provide circuit-breaker open/closed status signalling for switchboard control and monitoring systems.

Key Advantages

  • High-current 5000 A Emax 2 air circuit breaker for demanding power-distribution systems.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • Ekip Dip LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • High 150 kA ultimate breaking capacity at 400/415 V AC.
  • 100 kA breaking capacity at 690 V AC for demanding higher-voltage distribution systems.
  • Withdrawable moving-part construction supports efficient isolation, inspection and maintenance.
  • Integrated earth-fault protection enhances protection of distribution equipment and circuits.

Key Features

  • ABB SACE Emax 2 E6.2V series.
  • 5000 A rated continuous current.
  • 4-pole configuration.
  • Ekip Dip LSIG electronic protection release.
  • Long-time overload protection (L).
  • Selective short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated earth-fault protection (G).
  • Overload release adjustment range: 2000–5000 A.
  • Short-time delayed short-circuit adjustment range: 3000–50000 A.
  • Instantaneous short-circuit adjustment range: 7500–75000 A.
  • Rated voltage: 690 V AC.
  • Four changeover auxiliary contacts for breaker status signalling.
  • Optional motor operating mechanism capability.

Reliable LSIG Protection for High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2V provide switching and protection for major low-voltage distribution circuits where high continuous currents and substantial prospective fault currents must be managed safely. The Ekip Dip LSIG release monitors circuit current and provides separate long-time, short-time, instantaneous and earth-fault protection functions, enabling comprehensive protection of conductors, busbars and connected electrical equipment.

The combination of 5000 A continuous current capability, selective LSIG protection and high short-circuit breaking performance makes the 1SDA073253R1 particularly suitable for large switchboards and critical distribution systems. Its withdrawable architecture also allows the breaker moving part to be isolated from the fixed section for inspection or servicing, supporting maintainability and continuity strategies in industrial power systems.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary protection and distribution.
  • Generator and power-generation distribution systems.
  • Manufacturing and process-industry switchboards.
  • Commercial and infrastructure electrical distribution.
  • Data centres and continuity-critical power systems.
  • High-current feeders requiring selective LSIG and earth-fault protection.

Technical Specifications

Series SACE Emax 2 E6.2
ABB order code 1SDA073253R1
Product type Air circuit breaker moving part
Performance level V
Rated continuous current (Iu) 5000 A
Number of poles 4
Trip unit Ekip Dip LSIG
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Overload release adjustment 2000–5000 A
Short-time delayed short-circuit adjustment 3000–50000 A
Instantaneous short-circuit adjustment 7500–75000 A
Rated voltage 690 V AC
Ultimate breaking capacity (Icu) at 400/415 V AC 150 kA
Ultimate breaking capacity (Icu) at 690 V AC 100 kA
Integrated earth-fault protection Yes
Installation Withdrawable
Construction Moving part (WMP)
Auxiliary contacts 4 changeover contacts
Motor operating mechanism Optional
DIN rail mounting No

Frequently Asked Questions

What is the ABB 1SDA073253R1?

The ABB 1SDA073253R1 is an Emax 2 E6.2V withdrawable air circuit breaker moving part rated at 5000 A, with four poles and an Ekip Dip LSIG electronic protection release.

What protection does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG provides long-time overload (L), selective short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection for comprehensive protection of high-current distribution circuits.

What is the breaking capacity of the ABB E6.2V 5000?

The E6.2V 5000 provides an ultimate short-circuit breaking capacity of 150 kA at 400/415 V AC and 100 kA at 690 V AC.

Is the ABB 1SDA073253R1 fixed or withdrawable?

It is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part, which is installed separately in the switchboard.

Where is the ABB E6.2V 5000 Ekip Dip LSIG typically used?

It is typically used in high-current low-voltage switchboards for industrial plants, transformer and generator distribution, infrastructure, data centres and other installations requiring high breaking capacity and comprehensive LSIG protection.

Trusted Protection for Critical Power Distribution

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and maintainable withdrawable construction to provide dependable protection and selective coordination for demanding low-voltage power-distribution systems.