1SDA073242R1 ABB E6.2H 5000 Ekip Dip LSI 4p WMP Air Circuit Breaker

1SDA073242R1 ABB E6.2H 5000 Ekip Dip LSI 4p WMP Air Circuit Breaker

ABB 1SDA073242R1 Emax 2 E6.2H 5000 is a 5000 A four-pole withdrawable air circuit breaker moving part with Ekip Dip LSI electronic overload, selective short-circuit and instantaneous protection.

SKU: 1SDA073242R1MPN: 1SDA073242R1
Price
List Price £42,019.67 ex VAT
Your Price (ex VAT) Save 25%
£31,514.75 25% OFF
You save £10,504.92 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £31,514.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£31,514.75

Why Choose the ABB E6.2H 5000 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB E6.2H 5000 Ekip Dip LSI 4p WMP, order code 1SDA073242R1, is a high-current SACE Emax 2 air circuit breaker moving part designed for protection and switching in demanding low-voltage power-distribution systems. Part of the ABB Emax 2 E6.2 series, this withdrawable four-pole breaker combines a 5000 A rated current with H-level breaking performance and an Ekip Dip LSI electronic protection release.

The integrated Ekip Dip LSI trip unit provides long-time overload (L), selective short-time short-circuit (S) and instantaneous short-circuit (I) protection. Protection parameters are configured using DIP switches, providing a practical and dependable method of adapting the breaker to the requirements of the protected distribution circuit.

The E6.2H 5000 provides an ultimate short-circuit breaking capacity of 100 kA from 380 through 690 V AC, with a rated operational voltage of 690 V AC and rated insulation voltage of 1000 V AC. Its withdrawable moving-part configuration is designed for use with the corresponding Emax 2 fixed part, supporting efficient isolation, inspection and maintenance in high-current switchboards.

Key Advantages

  • High-current 5000 A Emax 2 air circuit breaker for demanding low-voltage distribution.
  • Four-pole configuration suitable for three-phase systems requiring neutral switching.
  • Ekip Dip LSI electronic trip unit provides overload, selective short-circuit and instantaneous protection.
  • High 100 kA ultimate breaking capacity throughout the specified 380–690 V AC range.
  • Withdrawable moving-part construction supports efficient switchboard isolation and maintenance.
  • DIP-switch adjustment enables straightforward configuration of protection settings.
  • Designed to IEC 60947-2 requirements for low-voltage circuit breakers.

Key Features

  • ABB SACE Emax 2 E6.2H series.
  • 5000 A rated current.
  • 4-pole configuration.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload protection (L).
  • Selective short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Long-time protection adjustment: 0.4–1 × In.
  • Short-time protection adjustment: 0.6–10 × In.
  • Instantaneous protection adjustment: 1.5–15 × In.
  • Rated operational voltage up to 690 V AC.
  • 100 kA ultimate breaking capacity at 380–690 V AC.
  • Withdrawable moving-part design for the corresponding Emax 2 fixed part.

Reliable Selective Protection for High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage distribution circuits against overload and short-circuit conditions. The Ekip Dip LSI release monitors circuit current and provides separate long-time, short-time and instantaneous protection functions, allowing the protection response to be coordinated with upstream and downstream devices.

The inclusion of adjustable short-time protection makes the LSI configuration particularly useful where selective coordination is required. Combined with the E6.2 frame's 5000 A current rating, high breaking capacity and withdrawable architecture, the 1SDA073242R1 provides a robust solution for large industrial and infrastructure switchboards where fault protection, continuity and maintainability are key requirements.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial power-distribution systems.
  • Transformer secondary protection and distribution.
  • Generator and power-generation distribution systems.
  • Manufacturing and process-industry switchboards.
  • Commercial and infrastructure electrical distribution.
  • Data centres and continuity-critical power systems.
  • High-current feeders requiring selective LSI protection.

Technical Specifications

Series SACE Emax 2 E6.2
ABB order code 1SDA073242R1
Product type Air circuit breaker moving part
Performance level H
Rated current 5000 A
Number of poles 4
Trip unit Ekip Dip LSI
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Protection setting method DIP switches
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Ultimate breaking capacity (Icu) at 380 V AC 100 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 100 kA
Ultimate breaking capacity (Icu) at 440 V AC 100 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 100 kA
Ultimate breaking capacity (Icu) at 690 V AC 100 kA
Installation Withdrawable
Construction Moving part (WMP)
Applicable standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073242R1?

The ABB 1SDA073242R1 is an Emax 2 E6.2H withdrawable air circuit breaker moving part rated at 5000 A, with four poles and an Ekip Dip LSI electronic protection release.

What protection does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI provides long-time overload (L), selective short-time short-circuit (S) and instantaneous short-circuit (I) protection, enabling coordinated protection of high-current distribution circuits.

What is the breaking capacity of the ABB E6.2H 5000?

This E6.2H configuration provides an ultimate short-circuit breaking capacity of 100 kA at rated operational voltages from 380 to 690 V AC.

Is the ABB 1SDA073242R1 fixed or withdrawable?

It is a withdrawable moving part (WMP) designed for use with the corresponding ABB SACE Emax 2 fixed part or cradle.

Where is the ABB E6.2H 5000 Ekip Dip LSI typically used?

It is typically used in high-current low-voltage switchboards for industrial plants, infrastructure, transformer and generator distribution, data centres and other installations requiring dependable selective circuit protection.

Trusted Protection for High-Current Power Distribution

ABB SACE Emax 2 air circuit breakers combine high-current switching, configurable electronic protection and maintainable withdrawable construction to provide dependable protection and selective coordination in demanding low-voltage power-distribution systems.