1SDA073185R1 ABB E4.2S 4000 Ekip Touch LSI 4p WMP Air Circuit Breaker 4000 A

1SDA073185R1 ABB E4.2S 4000 Ekip Touch LSI 4p WMP Air Circuit Breaker 4000 A

ABB 1SDA073185R1 E4.2S 4000 Ekip Touch LSI 4p WMP is a 4000 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Touch LSI electronic protection and 85 kA breaking capacity at 400/415 V AC.

SKU: 1SDA073185R1MPN: 1SDA073185R1
Price
List Price £32,879.00 ex VAT
Your Price (ex VAT) Save 25%
£24,659.25 25% OFF
You save £8,219.75 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,659.25
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,659.25

Why Choose the ABB E4.2S 4000 Ekip Touch LSI 4p WMP Air Circuit Breaker?

The ABB E4.2S 4000 Ekip Touch LSI 4p WMP, order code 1SDA073185R1, is a high-current four-pole air circuit breaker moving part from the ABB SACE Emax 2 range. Rated at 4000 A, it is designed for protection and switching in demanding low-voltage industrial, commercial, infrastructure and critical-power distribution systems.

This E4.2S breaker incorporates an advanced Ekip Touch LSI solid-state electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. Protection settings are accessible through the touchscreen interface, with adjustable long-time, selective short-time and instantaneous thresholds supporting effective coordination within complex electrical distribution networks.

The S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, remaining at 85 kA at 440 V AC and reducing to 66 kA at 500/525 V AC and 690 V AC. Its WMP configuration is the moving part of a withdrawable Emax 2 breaker system, providing a service-friendly solution for high-current switchboards.

Key Advantages

  • High-current 4000 A ABB SACE Emax 2 air circuit breaker.
  • Four-pole (4P) configuration for demanding low-voltage distribution systems.
  • 85 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • Advanced Ekip Touch LSI electronic trip unit with touchscreen configuration.
  • Long-time, short-time and instantaneous protection provides comprehensive overcurrent protection.
  • Adjustable short-time protection supports selective coordination between protective devices.
  • 1000 V AC insulation voltage and 12 kV impulse withstand voltage support robust switchboard integration.
  • Withdrawable moving-part construction supports efficient inspection, servicing and replacement.

Key Features

  • ABB SACE Emax 2 E4.2 frame.
  • E4.2S performance level.
  • 4000 A rated current.
  • Four-pole (4P) configuration.
  • Neutral pole rated at 100% of Iu.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Overload protection adjustable from 0.4–1 × In.
  • Short-time protection adjustable from 0.6–10 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • 85 kA Icu at 400/415 V AC.
  • 690 V AC rated operational voltage.
  • Four auxiliary contacts.
  • Breaker open/closed position indication.

Advanced Touchscreen LSI Protection for 4000 A Distribution

The ABB E4.2S 4000 combines high-current switching capability with the advanced configuration interface of the Ekip Touch LSI electronic release. Long-time protection responds to sustained overload conditions, short-time protection provides a configurable delayed response that supports selective coordination, and instantaneous protection rapidly disconnects severe short-circuit faults.

With a 4000 A current rating, 85 kA breaking capacity at 400/415 V AC and a rated operational voltage up to 690 V AC, the E4.2S is well suited to demanding main-distribution and high-current feeder applications. Its withdrawable architecture allows the moving breaker portion to be removed from its compatible fixed part for inspection or servicing, supporting maintainability in critical switchboards.

Typical Applications

  • Main incoming protection for high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current feeder and busbar protection.
  • Manufacturing and process plants.
  • Large commercial building electrical distribution.
  • Data centres and critical infrastructure.
  • Utility and infrastructure distribution systems.
  • Transformer and generator distribution switchboards.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073185R1
Product group Emax2 Air Circuit Breaker
EAN / GTIN 8015644770358
Product type Air circuit breaker moving part
Frame E4.2
Performance level S
Rated current (In) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50 / 60 Hz
Icu at 380 V AC 85 kA
Icu at 400/415 V AC 85 kA
Icu at 440 V AC 85 kA
Icu at 500/525 V AC 66 kA
Icu at 690 V AC 66 kA
Number of poles 4
Neutral pole current 100% of Iu
Current type AC
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Overload protection adjustment 0.4–1 × In / 1600–4000 A
Short-time protection adjustment 0.6–10 × In / 2400–40,000 A
Instantaneous protection adjustment 1.5–15 × In / 6000–60,000 A
Protection interface Touchscreen display
Integrated earth-fault protection No
Construction Withdrawable / draw-out moving part
Auxiliary contacts 4
Breaker position indication Open / closed
Electrical durability 5000 cycles at Ue ≤ 440 V; 4000 cycles at 500–690 V
Mechanical durability 15,000 cycles
Power loss 900 W
Dimensions (W × H × D) 551 × 425 × 383 mm
Product net weight 64 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073185R1 used for?

The ABB 1SDA073185R1 is a 4000 A four-pole SACE Emax 2 air circuit breaker moving part designed for switching and selective protection in demanding high-current low-voltage power distribution systems.

What protection unit is fitted to the ABB E4.2S 4000 1SDA073185R1?

It is fitted with an Ekip Touch LSI solid-state electronic trip unit, providing adjustable long-time overload, short-time short-circuit and instantaneous short-circuit protection through a touchscreen interface.

What is the breaking capacity of the ABB E4.2S 4000?

The E4.2S 4000 has a rated ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC. Its Icu is also 85 kA at 380 V and 440 V AC, and 66 kA at 500/525 V and 690 V AC.

What protection adjustment ranges are available on the Ekip Touch LSI release?

The long-time overload protection is adjustable from 0.4–1 × In, the selective short-time protection from 0.6–10 × In, and the instantaneous short-circuit protection from 1.5–15 × In.

Is the ABB E4.2S 4000 Ekip Touch LSI 4p WMP withdrawable?

Yes. The 1SDA073185R1 is the moving part of a withdrawable Emax 2 air circuit breaker and is designed to operate with a compatible fixed part, supporting efficient inspection, servicing and replacement.

Trusted Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, intuitive touchscreen configuration and service-friendly withdrawable construction for dependable high-current power distribution in demanding industrial, commercial and infrastructure installations.