ABB 1SDA073173R1 is a SACE Emax 2 E4.2N 4000 A four-pole withdrawable air circuit breaker moving part with an Ekip Dip LSIG electronic trip unit providing adjustable overload, short-circuit and ground-fault protection for high-current low-voltage power distribution systems.
£21,706.57
The ABB 1SDA073173R1 is a high-current SACE Emax 2 E4.2N air circuit breaker moving part engineered for protection and switching in demanding low-voltage power distribution systems. This four-pole withdrawable unit is rated at 4000 A and incorporates an Ekip Dip LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
As part of the ABB SACE Emax 2 range, the E4.2N combines substantial current-carrying capability with configurable electronic protection and service-friendly withdrawable construction. The Ekip Dip LSIG release provides adjustable L, S, I and G protection functions, making the breaker suitable for coordinated protection of major incomers, feeders and distribution circuits without requiring the touch-screen interface of higher-level Ekip releases.
Rated for operation up to 690 V AC, the E4.2N 4000 provides a rated ultimate short-circuit breaking capacity of 66 kA across the 380–690 V AC range. Its four-pole configuration, 100% neutral-pole current rating and withdrawable moving-part architecture make it particularly suitable for high-current industrial, commercial and infrastructure switchboards requiring comprehensive LSIG protection.
Air circuit breakers such as the ABB SACE Emax 2 protect major low-voltage electrical systems against damaging overloads, short circuits and earth faults while providing dependable high-current switching and isolation. The Ekip Dip LSIG release combines adjustable long-time, short-time, instantaneous and ground-fault functions, enabling comprehensive protection and coordination of major incomers and high-current feeders.
The E4.2N platform combines a substantial 4000 A current rating with a 66 kA ultimate short-circuit breaking capacity throughout the 380–690 V AC range. Its withdrawable architecture enables the moving part to be separated from the corresponding fixed section for inspection, maintenance or replacement, supporting serviceability in critical switchboard installations.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA073173R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4.2 |
| Performance level | N |
| Rated current | 4000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50/60 Hz |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Current type | AC |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time, instantaneous and ground fault |
| Overload protection adjustment | 0.4–1 × In |
| Overload protection range | 1600–4000 A |
| Short-time protection adjustment | 0.6–10 × In |
| Short-time protection range | 2400–40000 A |
| Instantaneous protection adjustment | 1.5–15 × In |
| Instantaneous protection range | 6000–60000 A |
| Ground-fault protection adjustment | 0.1–1 × In |
| Integrated ground-fault protection | Yes |
| Rated ultimate short-circuit breaking capacity (Icu) | 66 kA at 380 V AC |
| Construction | Withdrawable / moving part |
| Auxiliary contacts | 4 |
| Circuit-breaker position indication | Open / closed |
| Electrical durability | 5000 cycles at Ue ≤ 440 V |
| Electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 15000 cycles |
| Mechanical operating frequency | 60 cycles per hour |
| Product net width | 551 mm |
| Product net height | 425 mm |
| Product net depth | 383 mm |
| Product net weight | 74 kg |
| EAN | 8015644770235 |
| Standard | IEC 60947-2 |
The ABB 1SDA073173R1 is a SACE Emax 2 E4.2N four-pole withdrawable air circuit breaker moving part rated at 4000 A and equipped with an Ekip Dip LSIG solid-state electronic trip unit.
The circuit breaker has a rated current of 4000 A and a rated operational voltage of 690 V AC.
The Ekip Dip LSIG release provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and ground-fault protection.
The E4.2N 4000 has a rated ultimate short-circuit breaking capacity of 66 kA at 380 V, 400/415 V, 440 V, 500/525 V and 690 V AC.
Yes. The G function of the Ekip Dip LSIG trip unit provides adjustable ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
The long-time overload protection is adjustable from 0.4–1 × In, corresponding to 1600–4000 A for this 4000 A breaker.
The moving part measures 551 mm wide × 425 mm high × 383 mm deep and has a net weight of 74 kg.
The 1SDA073173R1 is the withdrawable moving part of the circuit breaker and is intended for use with the corresponding ABB SACE Emax 2 fixed part.
ABB SACE Emax 2 air circuit breakers are engineered for demanding industrial, commercial and infrastructure power-distribution systems, combining high-current switching capability, configurable electronic protection and service-friendly modular construction.