1SDA073142R1 ABB E4.2H 3200 Ekip Dip LSI 4p WMP Air Circuit Breaker

1SDA073142R1 ABB E4.2H 3200 Ekip Dip LSI 4p WMP Air Circuit Breaker

ABB 1SDA073142R1 E4.2H 3200 Ekip Dip LSI 4p WMP is a 3200 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LSI electronic protection and 100 kA breaking capacity at 400–440 V AC.

SKU: 1SDA073142R1MPN: 1SDA073142R1
Price
List Price £23,777.36 ex VAT
Your Price (ex VAT) Save 25%
£17,833.02 25% OFF
You save £5,944.34 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,833.02
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,833.02

Why Choose the ABB E4.2H 3200 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB E4.2H 3200 Ekip Dip LSI 4p WMP, order code 1SDA073142R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in demanding low-voltage power distribution systems. Rated at 3200 A, this withdrawable moving part combines the E4.2 frame with ABB's H short-circuit performance level and an Ekip Dip LSI electronic trip unit.

The Ekip Dip LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. This combination supports coordinated protection of transformers, feeders and distribution circuits, while the Ekip Dip platform provides straightforward electronic adjustment of the principal protection functions.

With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC, the E4.2H 3200 is engineered for networks with substantial prospective fault currents. Its four-pole withdrawable moving-part construction supports efficient maintenance and replacement when installed with the corresponding ABB SACE Emax 2 fixed chassis.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 3200 A rated current for high-current industrial, commercial and infrastructure applications.
  • Four-pole configuration with 100% neutral-pole current capability.
  • Ekip Dip LSI electronic trip unit provides overload, selective short-circuit and instantaneous short-circuit protection.
  • 100 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 85 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 100% Ics-to-Icu performance provides full service breaking capacity at the specified voltages.
  • Withdrawable moving-part construction supports efficient switchboard inspection, servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E4.2H air circuit breaker platform.
  • 3200 A rated current.
  • Four-pole construction.
  • Ekip Dip LSI solid-state electronic release.
  • Long-time overload (L), short-time selective (S) and instantaneous short-circuit (I) protection.
  • 100 kA Icu at 400–440 V AC.
  • 85 kA Icu at 500–690 V AC.
  • 85 kA short-time withstand current for 1 s.
  • 66 kA short-time withstand current for 3 s.
  • 12 kV rated impulse withstand voltage.
  • Suitable for 690 V IT networks.
  • Four auxiliary contacts fitted.
  • Circuit-breaker open/closed position indication.
  • Withdrawable moving part for connection through a separate fixed chassis.

Selective Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection for high-current low-voltage electrical networks. The E4.2H platform combines a substantial 3200 A continuous-current rating with high short-circuit performance, making it suitable for main distribution systems where significant prospective fault currents require robust protection.

The Ekip Dip LSI trip unit adds short-time protection to the long-time overload and instantaneous functions, enabling improved selective coordination between upstream and downstream protective devices. Combined with an 85 kA 1-second short-time withstand rating and 100% service breaking capacity, this configuration is well suited to transformers, main feeders and high-current distribution circuits where continuity and selectivity are important.

Typical Applications

  • Main low-voltage distribution switchboards.
  • High-current industrial power distribution systems.
  • Transformer secondary protection.
  • Main and high-current feeder protection.
  • Manufacturing plants and process facilities.
  • Data centres and critical power infrastructure.
  • Commercial and infrastructure electrical installations.
  • Large switchgear and power distribution systems.

Technical Specifications

Series SACE Emax 2
Product group Emax2 Air Circuit Breaker
Order code / SKU 1SDA073142R1
EAN 8015644769925
Product type Air circuit breaker moving part
Frame E4.2
Short-circuit performance level H
Current type AC
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Number of poles 4
Neutral pole current 100%
Trip unit Ekip Dip LSI
Trip-unit type Solid-state electronic release
Protection functions L, S, I
Integrated earth-fault protection No
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 500 / 525 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 380–440 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 500–690 V AC 85 kA
Ics as percentage of Icu 100%
Short-time withstand current (Icw) 85 kA for 1 s; 66 kA for 3 s
Suitable for IT networks Yes, up to 690 V
Installation Withdrawable
Construction Moving part for separate fixed chassis
Auxiliary contacts 4
Open/closed indication Yes
Connecting capacity 3000 mm²
Power loss 743 W
Mechanical durability 20,000 cycles
Mechanical operating rate 60 cycles per hour
Electrical durability 7,000 cycles
Electrical operating rate 20 cycles per hour
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA073142R1 used for?

The ABB 1SDA073142R1 is a 3200 A four-pole withdrawable air circuit breaker moving part designed for switching and selective protection of high-current low-voltage power distribution systems.

What protection unit is fitted to the ABB E4.2H 3200?

The circuit breaker is fitted with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection.

What is the current rating of the ABB 1SDA073142R1?

The E4.2H 3200 has a rated current and rated uninterrupted current of 3200 A.

What is the breaking capacity of the ABB E4.2H 3200?

The E4.2H 3200 provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC.

Is the ABB 1SDA073142R1 a fixed or withdrawable circuit breaker?

The 1SDA073142R1 is the withdrawable moving part of the circuit breaker and is designed for use with the corresponding ABB SACE Emax 2 fixed chassis.

Trusted Power Distribution Technology from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, selective electronic protection and withdrawable construction for dependable switching and protection in demanding industrial, commercial and infrastructure power distribution systems.