ABB 1SDA073142R1 E4.2H 3200 Ekip Dip LSI 4p WMP is a 3200 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LSI electronic protection and 100 kA breaking capacity at 400–440 V AC.
£17,833.02
The ABB E4.2H 3200 Ekip Dip LSI 4p WMP, order code 1SDA073142R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in demanding low-voltage power distribution systems. Rated at 3200 A, this withdrawable moving part combines the E4.2 frame with ABB's H short-circuit performance level and an Ekip Dip LSI electronic trip unit.
The Ekip Dip LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection. This combination supports coordinated protection of transformers, feeders and distribution circuits, while the Ekip Dip platform provides straightforward electronic adjustment of the principal protection functions.
With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC, the E4.2H 3200 is engineered for networks with substantial prospective fault currents. Its four-pole withdrawable moving-part construction supports efficient maintenance and replacement when installed with the corresponding ABB SACE Emax 2 fixed chassis.
Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection for high-current low-voltage electrical networks. The E4.2H platform combines a substantial 3200 A continuous-current rating with high short-circuit performance, making it suitable for main distribution systems where significant prospective fault currents require robust protection.
The Ekip Dip LSI trip unit adds short-time protection to the long-time overload and instantaneous functions, enabling improved selective coordination between upstream and downstream protective devices. Combined with an 85 kA 1-second short-time withstand rating and 100% service breaking capacity, this configuration is well suited to transformers, main feeders and high-current distribution circuits where continuity and selectivity are important.
| Series | SACE Emax 2 |
|---|---|
| Product group | Emax2 Air Circuit Breaker |
| Order code / SKU | 1SDA073142R1 |
| EAN | 8015644769925 |
| Product type | Air circuit breaker moving part |
| Frame | E4.2 |
| Short-circuit performance level | H |
| Current type | AC |
| Rated current (In) | 3200 A |
| Rated uninterrupted current (Iu) | 3200 A |
| Number of poles | 4 |
| Neutral pole current | 100% |
| Trip unit | Ekip Dip LSI |
| Trip-unit type | Solid-state electronic release |
| Protection functions | L, S, I |
| Integrated earth-fault protection | No |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 / 525 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 380–440 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 500–690 V AC | 85 kA |
| Ics as percentage of Icu | 100% |
| Short-time withstand current (Icw) | 85 kA for 1 s; 66 kA for 3 s |
| Suitable for IT networks | Yes, up to 690 V |
| Installation | Withdrawable |
| Construction | Moving part for separate fixed chassis |
| Auxiliary contacts | 4 |
| Open/closed indication | Yes |
| Connecting capacity | 3000 mm² |
| Power loss | 743 W |
| Mechanical durability | 20,000 cycles |
| Mechanical operating rate | 60 cycles per hour |
| Electrical durability | 7,000 cycles |
| Electrical operating rate | 20 cycles per hour |
| Standard | IEC 60947-2 |
The ABB 1SDA073142R1 is a 3200 A four-pole withdrawable air circuit breaker moving part designed for switching and selective protection of high-current low-voltage power distribution systems.
The circuit breaker is fitted with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time selective short-circuit and instantaneous short-circuit protection.
The E4.2H 3200 has a rated current and rated uninterrupted current of 3200 A.
The E4.2H 3200 provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC.
The 1SDA073142R1 is the withdrawable moving part of the circuit breaker and is designed for use with the corresponding ABB SACE Emax 2 fixed chassis.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, selective electronic protection and withdrawable construction for dependable switching and protection in demanding industrial, commercial and infrastructure power distribution systems.