1SDA073137R1 ABB E4.2S 3200 Ekip G Touch LSIG 4p WMP Air Circuit Breaker 3200 A

1SDA073137R1 ABB E4.2S 3200 Ekip G Touch LSIG 4p WMP Air Circuit Breaker 3200 A

ABB 1SDA073137R1 E4.2S 3200 Ekip G Touch LSIG 4p WMP is a 3200 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with generator-oriented Ekip G Touch LSIG electronic protection, 85 kA breaking capacity at 440 V AC and 66 kA short-time withstand capability for 1 s.

SKU: 1SDA073137R1MPN: 1SDA073137R1
Price
List Price £26,311.03 ex VAT
Your Price (ex VAT) Save 25%
£19,733.27 25% OFF
You save £6,577.76 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £19,733.27
Trade pricing is personalised to your account

Manufacturer Lead Time

£19,733.27

Why Choose the ABB E4.2S 3200 Ekip G Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E4.2S 3200 Ekip G Touch LSIG 4p WMP, order code 1SDA073137R1, is a high-current four-pole air circuit breaker moving part from the ABB SACE Emax 2 range. Rated at 3200 A, it is engineered for demanding low-voltage power distribution and generator applications requiring advanced electronic protection, high short-circuit performance and service-friendly withdrawable construction.

This E4.2S breaker is equipped with an Ekip G Touch LSIG solid-state electronic trip unit. The generator-oriented Ekip G Touch platform combines long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection with an advanced touchscreen interface, providing comprehensive protection for generators and associated distribution systems.

The S performance level provides a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC, while the E4.2 frame provides a rated short-time withstand current of 66 kA for 1 s. The WMP configuration is the moving part of a withdrawable Emax 2 breaker system, enabling efficient inspection, maintenance and replacement when installed with the corresponding fixed part.

Key Advantages

  • High-current 3200 A ABB SACE Emax 2 air circuit breaker.
  • Four-pole configuration for demanding AC power-distribution and generator systems.
  • 85 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 66 kA short-time withstand current for 1 s.
  • Advanced Ekip G Touch LSIG electronic trip unit developed for generator protection applications.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • Touchscreen interface provides convenient access to protection settings and electrical information.
  • Withdrawable moving-part construction supports efficient switchboard inspection, servicing and replacement.

Key Features

  • ABB SACE Emax 2 E4.2 frame.
  • E4.2S short-circuit performance level.
  • 3200 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • Ekip G Touch LSIG solid-state electronic release.
  • Generator-oriented electronic protection functionality.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Earth-fault (G) protection.
  • 85 kA Icu at 440 V AC.
  • 66 kA Icw for 1 s.
  • Four auxiliary contacts fitted as standard.
  • Circuit-breaker open/closed position indication.
  • Withdrawable moving-part format for service-friendly installations.

Advanced Generator and Power-Distribution Protection

The ABB E4.2S 3200 combines the high-current switching capability of the SACE Emax 2 platform with the generator-oriented functionality of the Ekip G Touch electronic release. Its LSIG protection functions provide coordinated response to sustained overloads, delayed short circuits, severe instantaneous faults and earth faults, helping protect generators and connected low-voltage distribution equipment.

With an 85 kA breaking capacity at 440 V AC, 66 kA short-time withstand capability for 1 s and a 3200 A current rating, the E4.2S is suited to high-power installations where robust fault handling and maintainability are important. Its withdrawable architecture allows the moving breaker section to be removed from the compatible fixed part for inspection or servicing.

Typical Applications

  • Generator protection and generator switchboards.
  • Main incoming protection for high-current low-voltage switchboards.
  • Industrial power generation and distribution systems.
  • Generator-to-bus and critical-power distribution systems.
  • Manufacturing and process plants.
  • Data centres and critical infrastructure.
  • Utility and infrastructure power systems.
  • High-current feeder and distribution protection.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073137R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker moving part
Frame E4.2
Performance level S
Rated uninterrupted current (Iu) 3200 A
Number of poles 4
Current type AC
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated short-time withstand current (Icw) for 1 s 66 kA
Trip unit Ekip G Touch LSIG
Release type Solid-state electronic
Protection functions Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G)
Application focus Generator and power-distribution protection
Construction Withdrawable / draw-out moving part
Auxiliary contacts 4
Breaker position indication Open / closed
Electrical durability 7,000 cycles
Mechanical durability 20,000 cycles
Dimensions (W × H × D) 551 × 425 × 383 mm
Net weight 64 kg
EAN 8015644769871

Frequently Asked Questions

What is the ABB 1SDA073137R1 used for?

The ABB 1SDA073137R1 is a 3200 A four-pole SACE Emax 2 air circuit breaker moving part designed for high-current generator and low-voltage power-distribution protection.

What protection unit is fitted to the ABB E4.2S 3200 1SDA073137R1?

It is fitted with an Ekip G Touch LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection with generator-oriented functionality.

What is the breaking capacity of the ABB E4.2S 3200?

The E4.2S 3200 has a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s.

Does the ABB 1SDA073137R1 provide earth-fault protection?

Yes. The G function of the Ekip G Touch LSIG release provides earth-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

Is the ABB E4.2S 3200 Ekip G Touch LSIG 4p WMP withdrawable?

Yes. The 1SDA073137R1 is the moving part of a withdrawable Emax 2 air circuit breaker and is designed for installation with the corresponding fixed part, which is ordered separately.

Trusted Generator Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine advanced generator-oriented electronic protection, high short-circuit performance and service-friendly withdrawable construction for dependable high-current power generation and distribution applications.