Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA073110R1 is a SACE Emax 2 E4.2V 2500 A four-pole withdrawable air circuit breaker moving part with an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator, overload, short-circuit and ground-fault protection.
£20,025.62
The ABB 1SDA073110R1 is a high-performance SACE Emax 2 E4.2V air circuit breaker moving part engineered for advanced generator and low-voltage power-distribution protection. This four-pole withdrawable unit has a rated uninterrupted current of 2500 A and incorporates ABB's Ekip G Hi-Touch LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
The Ekip G Hi-Touch release is specifically suited to demanding generator applications and combines configurable LSIG protection with advanced measurement and power-quality monitoring. Integrated Ekip Measuring Pro and Network Analyzer functionality provides enhanced electrical supervision, while the touch-screen interface supports intuitive configuration and access to operating information.
With a rated operational voltage of 690 V AC, an ultimate short-circuit breaking capacity of 150 kA at 380–440 V AC and 100 kA at 500–690 V AC, the E4.2V 2500 is designed for systems with exceptionally high prospective fault currents. Its four-pole configuration, generator-specific protection capabilities and withdrawable moving-part construction make it a strong choice for critical generation and high-capacity distribution installations.
The ABB SACE Emax 2 E4.2V combines high-current switching with sophisticated electronic protection for generator and critical distribution systems. Its Ekip G Hi-Touch LSIG release provides adjustable overload, selective short-circuit, instantaneous and ground-fault protection while incorporating generator-specific protection functions, advanced electrical measurement and real-time power-quality analysis.
The E4.2V platform is engineered for installations with exceptionally high prospective fault currents. Breaking capacities of up to 150 kA at 380–440 V AC provide robust fault interruption, while the withdrawable architecture allows the moving part to be separated from its corresponding fixed chassis for inspection, servicing or replacement.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA073110R1 |
| Product type | Air circuit breaker moving part |
| Frame | E4.2 |
| Performance level | V |
| Rated uninterrupted current (Iu) | 2500 A |
| Rated current (In) | 2500 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50/60 Hz |
| Number of poles | 4 |
| Current type | AC |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time, instantaneous and ground fault |
| Overload protection adjustment | 0.4–1 × In |
| Short-time protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Ground-fault protection adjustment | 0.1–1 × In |
| Rated ultimate short-circuit breaking capacity (Icu) | 150 kA at 380 V AC |
| Generator protection | Yes |
| Measurement module | Ekip Measuring Pro |
| Power-quality analysis | Integrated Network Analyzer |
| Configuration interface | Touch-screen display |
| Construction | Withdrawable / moving part |
| Main-circuit connection | Connection through separate chassis part |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open / closed |
| Motor drive | Optional |
| Protection rating | IP30 |
| Electrical durability | 8000 cycles at Ue ≤ 440 V |
| Mechanical durability | 20000 cycles |
| Product net width | 551 mm |
| Product net height | 425 mm |
| Product net depth | 383 mm |
| Product net weight | 85 kg |
| EAN | 8015644769604 |
| Standard | IEC 60947-2 |
The ABB 1SDA073110R1 is a SACE Emax 2 E4.2V four-pole withdrawable air circuit breaker moving part rated at 2500 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.
The circuit breaker has a rated uninterrupted current of 2500 A and a rated operational voltage of 690 V AC.
The Ekip G Hi-Touch LSIG release provides long-time overload, selective short-time short-circuit, instantaneous short-circuit and ground-fault protection, together with generator-specific protection functionality.
The E4.2V 2500 provides an ultimate short-circuit breaking capacity of 150 kA at 380–440 V AC and 100 kA at 500–690 V AC.
Yes. The Ekip G Hi-Touch release incorporates protection functionality specifically intended for generator applications, making this configuration suitable for demanding power-generation systems.
Yes. The LSIG protection package includes adjustable ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
The Ekip G Hi-Touch configuration includes Ekip Measuring Pro and an integrated Network Analyzer, providing advanced electrical measurement and power-quality monitoring functionality.
The 1SDA073110R1 is the withdrawable moving part of the circuit breaker and connects to the main circuit through the corresponding separate ABB SACE Emax 2 chassis part.
ABB SACE Emax 2 air circuit breakers are engineered for demanding industrial, infrastructure and power-generation systems, combining high short-circuit performance, advanced electronic protection, electrical monitoring and service-friendly modular construction.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.