1SDA073102R1 ABB E4.2V 2500 Ekip Dip LSI 4p WMP Air Circuit Breaker 2500 A

1SDA073102R1 ABB E4.2V 2500 Ekip Dip LSI 4p WMP Air Circuit Breaker 2500 A

ABB 1SDA073102R1 E4.2V 2500 Ekip Dip LSI 4p WMP is a 2500 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LSI electronic protection and 150 kA breaking capacity at 400 V AC.

SKU: 1SDA073102R1MPN: 1SDA073102R1
Price
List Price £20,970.87 ex VAT
Your Price (ex VAT) Save 25%
£15,728.15 25% OFF
You save £5,242.72 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,728.15
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,728.15

Why Choose the ABB E4.2V 2500 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB E4.2V 2500 Ekip Dip LSI 4p WMP, order code 1SDA073102R1, is a high-performance four-pole air circuit breaker (ACB) moving part from the ABB SACE Emax 2 range, designed for protection and switching in demanding low-voltage power distribution systems. With a rated uninterrupted current of 2500 A, it provides robust circuit protection for high-current industrial, commercial, infrastructure and critical-power switchboards.

This E4.2V breaker is equipped with an Ekip Dip LSI electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. The addition of adjustable short-time protection supports selective coordination between upstream and downstream protective devices, helping isolate faults while maintaining continuity elsewhere in the electrical distribution system.

The V performance level provides exceptionally high short-circuit capability, with a rated ultimate short-circuit breaking capacity of 150 kA at 400 V AC and a rated short-time withstand current of 100 kA for 1 s. Its four-pole WMP configuration uses ABB's withdrawable architecture, allowing the moving part to connect through a separate chassis for service-friendly installation in high-availability switchboards.

Key Advantages

  • High-current 2500 A ABB SACE Emax 2 air circuit breaker.
  • Four-pole configuration for demanding low-voltage distribution systems.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Ekip Dip LSI electronic trip unit provides three-stage overcurrent protection.
  • Long-time, short-time and instantaneous protection provides flexible fault response.
  • Short-time protection supports selective coordination throughout the distribution network.
  • 100 kA short-time withstand capability for 1 s supports demanding power-distribution applications.
  • Withdrawable moving-part construction supports efficient switchboard inspection, servicing and replacement.

Key Features

  • ABB SACE Emax 2 E4.2 frame.
  • E4.2V very-high-breaking-capacity performance class.
  • 2500 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 1000 A minimum overload release setting.
  • 1500 A minimum short-time delayed short-circuit setting.
  • 3750 A minimum instantaneous short-circuit setting.
  • 150 kA Icu at 400 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • 690 V AC rated voltage.
  • Four auxiliary change-over contacts and switched-off indication.

High-Performance LSI Protection for Critical Power Distribution

Air circuit breakers such as the ABB E4.2V protect high-current electrical distribution circuits against potentially damaging overload and short-circuit conditions. The Ekip Dip LSI electronic release combines long-time, short-time and instantaneous protection functions, allowing different levels of overcurrent to be detected and cleared according to the configured protection characteristics.

The E4.2V is particularly suited to installations with very high prospective fault currents. Its 150 kA breaking capacity at 400 V AC and 100 kA short-time withstand capability for 1 s provide robust fault-handling performance, while the short-time protection function assists with selective coordination and the withdrawable Emax 2 architecture supports efficient switchboard maintenance.

Typical Applications

  • Main incoming protection for high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-fault-level feeder and distribution protection.
  • Manufacturing and process plants.
  • Large commercial building electrical distribution.
  • Data centres and critical infrastructure.
  • Utility and infrastructure distribution systems.
  • Generator and transformer distribution switchboards.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073102R1
Product type Air circuit breaker moving part
Frame E4.2
Performance level V
Rated uninterrupted current (Iu) 2500 A
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Rated short-time withstand current (Icw) for 1 s 100 kA
Number of poles 4
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Minimum overload release setting 1000 A
Minimum short-time delayed short-circuit setting 1500 A
Minimum instantaneous short-circuit setting 3750 A
Integrated earth-fault protection No
Construction Withdrawable / draw-out moving part
Main-circuit connection Connection at separate chassis part
Control element Push button
Auxiliary change-over contacts 4
Switched-off indication Yes
Integrated motor drive No
Optional motor drive Yes
Degree of protection IP30
Net weight 74 kg

Frequently Asked Questions

What is the ABB 1SDA073102R1 used for?

The ABB 1SDA073102R1 is a 2500 A four-pole Emax 2 air circuit breaker moving part designed for high-current switching and protection in demanding low-voltage power distribution systems.

What protection unit is fitted to the ABB E4.2V 2500 1SDA073102R1?

It is fitted with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E4.2V 2500?

The E4.2V 2500 has a rated ultimate short-circuit breaking capacity of 150 kA at 400 V AC, providing very high fault-breaking capability for demanding power distribution systems.

What is the advantage of LSI protection?

The LSI protection functions provide long-time overload, short-time short-circuit and instantaneous short-circuit protection, with the short-time function helping support selective coordination between protective devices.

Is the ABB E4.2V 2500 Ekip Dip LSI 4p WMP withdrawable?

Yes. This WMP product uses a withdrawable moving-part construction with connection at a separate chassis part, supporting convenient inspection, servicing and replacement in compatible switchboards.

Trusted Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine configurable electronic protection, exceptional short-circuit performance and service-friendly withdrawable construction for dependable high-current power distribution in demanding industrial, commercial and infrastructure installations.