1SDA073101R1 ABB E4.2V 2500 Ekip Dip LI 4p WMP Air Circuit Breaker 2500 A

1SDA073101R1 ABB E4.2V 2500 Ekip Dip LI 4p WMP Air Circuit Breaker 2500 A

ABB 1SDA073101R1 E4.2V 2500 Ekip Dip LI 4p WMP is a 2500 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Dip LI electronic protection and 150 kA breaking capacity at 400 V AC.

SKU: 1SDA073101R1MPN: 1SDA073101R1
Price
List Price £20,483.61 ex VAT
Your Price (ex VAT) Save 25%
£15,362.71 25% OFF
You save £5,120.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,362.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,362.71

Why Choose the ABB E4.2V 2500 Ekip Dip LI 4p WMP Air Circuit Breaker?

The ABB E4.2V 2500 Ekip Dip LI 4p WMP, order code 1SDA073101R1, is a high-performance four-pole air circuit breaker (ACB) moving part from the ABB SACE Emax 2 range, engineered for protection and switching in demanding low-voltage power distribution systems. With a rated uninterrupted current of 2500 A, it is designed for high-current industrial, commercial, infrastructure and critical-power switchboards.

This E4.2V breaker is equipped with an Ekip Dip LI electronic trip unit, providing long-time overload (L) and instantaneous short-circuit (I) protection. The Ekip Dip platform provides dependable electronic overcurrent protection with adjustable thresholds, allowing the breaker protection to be coordinated with the characteristics of the connected distribution system.

The V performance level delivers exceptionally high short-circuit performance, with a rated ultimate short-circuit breaking capacity of 150 kA at 400 V AC and a rated short-time withstand current of 100 kA for 1 s. The four-pole WMP configuration is the moving part of a withdrawable Emax 2 breaker system, supporting efficient inspection, maintenance and replacement in high-availability switchboards.

Key Advantages

  • High-current 2500 A ABB SACE Emax 2 air circuit breaker.
  • Four-pole configuration for demanding low-voltage distribution systems.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Ekip Dip LI electronic trip unit provides overload and instantaneous short-circuit protection.
  • Adjustable protection thresholds support coordination with the electrical installation.
  • 100 kA short-time withstand current for 1 s supports high-selectivity distribution systems.
  • Withdrawable moving-part construction supports efficient switchboard maintenance and replacement.
  • Part of ABB's modular SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E4.2 frame.
  • E4.2V very-high-breaking-capacity performance class.
  • 2500 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • Ekip Dip LI electronic protection release.
  • Long-time overload (L) protection.
  • Instantaneous short-circuit (I) protection.
  • 1000–2500 A adjustable overload release range.
  • 3750–37,500 A adjustable instantaneous short-circuit release range.
  • 150 kA Icu at 400 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Rated for low-voltage AC distribution systems up to 690 V AC.
  • Withdrawable moving-part format for service-friendly switchboard installations.

High-Performance Protection for Critical Power Distribution

Air circuit breakers such as the ABB E4.2V protect high-current electrical distribution circuits against potentially damaging overload and short-circuit conditions. The Ekip Dip LI electronic release provides long-time overload and instantaneous short-circuit protection, with adjustable thresholds allowing the protection characteristics to be matched to the requirements of the installation.

The E4.2V is particularly suited to systems with very high prospective fault currents. Its 150 kA breaking capacity at 400 V AC and 100 kA short-time withstand capability for 1 s provide robust fault-handling performance, while the withdrawable Emax 2 architecture supports efficient servicing in critical switchboards where system availability and maintainability are important.

Typical Applications

  • Main incoming protection for high-current low-voltage switchboards.
  • Industrial power distribution systems.
  • High-fault-level feeder protection.
  • Manufacturing and process plants.
  • Large commercial building electrical distribution.
  • Data centres and critical infrastructure.
  • Utility and infrastructure distribution systems.
  • Generator and transformer distribution switchboards.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073101R1
Product type Air circuit breaker moving part
Frame E4.2
Performance level V
Rated uninterrupted current (Iu) 2500 A
Rated operational voltage up to 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Rated short-time withstand current (Icw) for 1 s 100 kA
Number of poles 4
Trip unit Ekip Dip LI
Release type Electronic
Protection functions Long-time overload (L) and instantaneous short-circuit (I)
Overload release adjustment range 1000–2500 A
Instantaneous short-circuit release adjustment range 3750–37,500 A
Construction Withdrawable / draw-out moving part
Main-circuit connection Connection through separate fixed part
Net weight 74 kg
EAN 8015644769512

Frequently Asked Questions

What is the ABB 1SDA073101R1 used for?

The ABB 1SDA073101R1 is a 2500 A four-pole Emax 2 air circuit breaker moving part designed for high-current switching and protection in demanding low-voltage power distribution systems.

What protection unit is fitted to the ABB E4.2V 2500 1SDA073101R1?

It is fitted with an Ekip Dip LI electronic trip unit, providing long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E4.2V 2500?

The E4.2V 2500 has a rated ultimate short-circuit breaking capacity of 150 kA at 400 V AC, making it suitable for distribution systems with very high prospective fault currents.

What protection settings are available on the Ekip Dip LI release?

The overload release can be adjusted over 1000–2500 A, while the instantaneous short-circuit protection has an adjustment range of 3750–37,500 A.

Is the ABB E4.2V 2500 Ekip Dip LI 4p WMP withdrawable?

Yes. This WMP version is the moving part of a withdrawable Emax 2 air circuit breaker and connects through a separate fixed part, supporting convenient inspection, servicing and replacement in compatible switchboards.

Trusted Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, exceptional short-circuit performance and service-friendly withdrawable construction for dependable high-current power distribution in demanding industrial, commercial and infrastructure installations.