1SDA073065R1 ABB E2.2H 2500 Ekip Touch LSI 4p WMP Air Circuit Breaker 2500 A

1SDA073065R1 ABB E2.2H 2500 Ekip Touch LSI 4p WMP Air Circuit Breaker 2500 A

ABB 1SDA073065R1 E2.2H 2500 Ekip Touch LSI 4p WMP is a 2500 A four-pole withdrawable SACE Emax 2 air circuit breaker moving part with Ekip Touch LSI electronic protection and 100 kA breaking capacity at 400/415 V AC.

SKU: 1SDA073065R1MPN: 1SDA073065R1
Price
List Price £17,540.68 ex VAT
Your Price (ex VAT) Save 25%
£13,155.51 25% OFF
You save £4,385.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,155.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,155.51

Why Choose the ABB E2.2H 2500 Ekip Touch LSI 4p WMP Air Circuit Breaker?

The ABB E2.2H 2500 Ekip Touch LSI 4p WMP, order code 1SDA073065R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in demanding low-voltage power distribution systems. With a rated uninterrupted current of 2500 A, it provides dependable protection for high-current industrial, commercial and infrastructure installations.

This E2.2H breaker is equipped with the advanced Ekip Touch LSI electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. The Ekip Touch platform combines configurable electronic protection with a touchscreen interface, while the short-time function supports selective coordination between protective devices in complex distribution networks.

The H performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC, with high fault-breaking performance maintained at higher operating voltages. Its four-pole WMP configuration is the moving part of a withdrawable Emax 2 breaker system, supporting efficient inspection, servicing and replacement in critical low-voltage switchboards.

Key Advantages

  • High-current 2500 A ABB SACE Emax 2 air circuit breaker.
  • Four-pole configuration for demanding low-voltage distribution systems.
  • 100 kA ultimate breaking capacity at 400/415 V AC.
  • Advanced Ekip Touch LSI electronic trip unit with configurable protection.
  • Provides long-time, short-time and instantaneous overcurrent protection.
  • Short-time protection supports selective coordination throughout the distribution network.
  • Withdrawable moving-part construction supports efficient maintenance and replacement.
  • Rated for operation in low-voltage AC systems up to 690 V AC.

Key Features

  • ABB SACE Emax 2 E2.2 frame.
  • E2.2H high-performance breaking class.
  • 2500 A rated uninterrupted current.
  • Four-pole (4P) configuration.
  • Ekip Touch LSI electronic protection release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 100 kA Icu at 400/415 V AC.
  • 85 kA Icu at 500–690 V AC.
  • 85 kA short-time withstand current for 1 s.
  • Touchscreen interface for protection configuration and monitoring.
  • Withdrawable moving part for service-friendly switchboard installations.

Advanced LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB E2.2H protect high-current electrical distribution circuits against potentially damaging overload and short-circuit conditions. The Ekip Touch LSI electronic release combines long-time, short-time and instantaneous protection functions, allowing the breaker to respond appropriately to different magnitudes and durations of overcurrent.

The short-time protection function is particularly useful where selective coordination between upstream and downstream protective devices is required. Combined with the E2.2H's high short-circuit performance and withdrawable Emax 2 architecture, this provides a robust and service-friendly protection solution for critical industrial and commercial switchboards.

Typical Applications

  • Main incoming protection for low-voltage switchboards.
  • Industrial power distribution systems.
  • High-current feeder and distribution protection.
  • Manufacturing and process plants.
  • Commercial building electrical distribution.
  • Data centres and critical infrastructure.
  • Utility and infrastructure distribution systems.
  • Generator and transformer distribution switchboards.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA073065R1
Product type Air circuit breaker moving part
Frame E2.2
Performance level H
Rated uninterrupted current (Iu) 2500 A
Rated operational voltage 690 V AC
Number of poles 4
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Overload protection adjustment range 1000–2500 A
Instantaneous protection adjustment range 3750–37,500 A
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 85 kA for 1 s; 66 kA for 3 s
Construction Withdrawable / draw-out moving part
Protection interface Ekip Touch touchscreen

Frequently Asked Questions

What is the ABB 1SDA073065R1 used for?

The ABB 1SDA073065R1 is a 2500 A four-pole Emax 2 air circuit breaker moving part designed for switching and protection in high-current low-voltage power distribution systems.

What protection unit is fitted to the ABB E2.2H 2500 1SDA073065R1?

It is fitted with an Ekip Touch LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E2.2H 2500?

The E2.2H 2500 has a rated ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and 85 kA at 500–690 V AC.

What does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI provides long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection, with an electronic touchscreen interface for configuration and monitoring.

Is the ABB E2.2H 2500 Ekip Touch LSI 4p WMP withdrawable?

Yes. This WMP product is the moving part of a withdrawable Emax 2 air circuit breaker, supporting convenient inspection, servicing and replacement in compatible low-voltage switchboards.

Trusted Protection from ABB SACE Emax 2

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high short-circuit performance and service-friendly withdrawable construction for dependable low-voltage power distribution in industrial, commercial and infrastructure installations.