1SDA073060R1 ABB E2.2S 2500 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

1SDA073060R1 ABB E2.2S 2500 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA073060R1 E2.2S 2500 Ekip G Hi-Touch LSIG 4p WMP is a 2500 A four-pole SACE Emax 2 withdrawable air circuit breaker moving part with advanced generator-oriented LSIG electronic protection and an 85 kA ultimate breaking capacity at 400/415/440 V AC.

SKU: 1SDA073060R1MPN: 1SDA073060R1
Price
List Price £21,146.22 ex VAT
Your Price (ex VAT) Save 25%
£15,859.67 25% OFF
You save £5,286.56 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £15,859.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£15,859.67

Why Choose the ABB E2.2S 2500 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2S 2500 Ekip G Hi-Touch LSIG 4p WMP, order code 1SDA073060R1, is a high-performance four-pole air circuit breaker moving part designed for advanced protection, monitoring and control in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, it combines a 2500 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic protection release.

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced measurement, monitoring and generator-protection functionality. Its sophisticated electronic architecture makes this breaker particularly suitable for critical power systems where comprehensive protection, selectivity and detailed electrical monitoring are required.

This E2.2S configuration has a 2500 A rated uninterrupted current, four-pole construction and a rated operational voltage of 690 V AC. The S performance level delivers an ultimate short-circuit breaking capacity of 85 kA at 400/415/440 V AC, while its withdrawable moving-part construction enables convenient inspection, maintenance and replacement within a compatible SACE Emax 2 fixed part.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding power distribution systems.
  • 2500 A rated uninterrupted current for high-current installations.
  • Four-pole configuration for switching and protecting three phases and neutral.
  • Advanced Ekip G Hi-Touch LSIG electronic protection release.
  • LSIG functionality provides overload, selective short-circuit, instantaneous and earth-fault protection.
  • Generator-oriented protection capabilities for complex electrical systems.
  • 85 kA ultimate short-circuit breaking capacity at 400/415/440 V AC.
  • 66 kA rated short-time withstand current for 1 s for robust system selectivity.
  • Withdrawable moving-part design supports efficient maintenance and reduced switchboard downtime.

Key Features

  • ABB SACE Emax 2 E2.2S frame.
  • 2500 A rated uninterrupted current.
  • Four-pole construction.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time overload protection (L).
  • Short-time selective short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Earth-fault protection (G).
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Advanced measurement, monitoring and protection functionality.
  • Suitable for IT networks up to 690 V.
  • Withdrawable moving part for compatible Emax 2 switchgear installations.

Advanced Generator and Power-System Protection

The ABB Ekip G Hi-Touch LSIG release combines comprehensive circuit protection with advanced functions intended for sophisticated power distribution and generator applications. Its electronic protection architecture supervises overload, delayed and instantaneous short-circuit conditions and earth faults while providing detailed measurement and monitoring capabilities for effective management of critical electrical networks.

SACE Emax 2 air circuit breakers are designed for installations where continuity of service, selectivity and dependable fault interruption are essential. The withdrawable construction allows the breaker moving part to be isolated and removed from its corresponding fixed part, simplifying maintenance and helping minimise disruption to critical switchboards and power distribution infrastructure.

Typical Applications

  • Industrial low-voltage power distribution switchboards.
  • Generator protection and power-generation systems.
  • Main incoming and outgoing feeder protection.
  • Transformer and distribution network protection.
  • Manufacturing and process industry installations.
  • Data centres and critical power infrastructure.
  • Commercial buildings and large infrastructure projects.
  • Utility, energy and smart-grid distribution systems.

Technical Specifications

Series SACE Emax 2
Order code 1SDA073060R1
Product type Air circuit breaker moving part
Frame E2.2S
Short-circuit performance level S
Rated uninterrupted current (Iu) 2500 A
Number of poles 4
Neutral pole current 100% of Iu
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions L, S, I, G
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400/415/440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500/690 V AC 66 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Current type AC
Installation Withdrawable moving part
Main circuit connection Connection through separate fixed part
Suitable for IT networks Yes, up to 690 V
Mechanical endurance 20,000 operating cycles
Electrical endurance at Ue ≤ 440 V 8,000 operating cycles
Electrical endurance at Ue 500–690 V 7,000 operating cycles
Standard IEC 60947-2
EAN 8015644769109

Frequently Asked Questions

What is the ABB 1SDA073060R1?

The ABB 1SDA073060R1 is an E2.2S 2500 Ekip G Hi-Touch LSIG four-pole withdrawable air circuit breaker moving part from the SACE Emax 2 range.

What is the rated current of the E2.2S 2500 Ekip G Hi-Touch LSIG?

The breaker has a rated uninterrupted current of 2500 A and is designed for high-current low-voltage power distribution and protection applications.

What protection functions does the Ekip G Hi-Touch LSIG provide?

The Ekip G Hi-Touch LSIG provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced monitoring, measurement and generator-oriented protection capabilities.

What is the breaking capacity of the ABB E2.2S 2500?

The E2.2S provides an ultimate short-circuit breaking capacity of 85 kA at 400/415/440 V AC and 66 kA at 500/690 V AC.

Is the ABB 1SDA073060R1 a withdrawable circuit breaker?

Yes. The 1SDA073060R1 is a withdrawable moving part designed for installation with the appropriate compatible SACE Emax 2 fixed part.

Trusted for Critical Power Distribution

ABB SACE Emax 2 air circuit breakers combine high fault-interruption performance, advanced electronic protection and intelligent monitoring to provide dependable control and protection for demanding industrial, infrastructure and power-generation systems.