1SDA073047R1 ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP Air Circuit Breaker 2500 A

1SDA073047R1 ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP Air Circuit Breaker 2500 A

ABB 1SDA073047R1 is a four-pole SACE Emax 2 E2.2N 2500 A withdrawable air circuit breaker with an Ekip G Touch LSIG electronic trip unit for advanced generator and low-voltage power distribution protection.

SKU: 1SDA073047R1MPN: 1SDA073047R1
Price
List Price £18,476.15 ex VAT
Your Price (ex VAT) Save 25%
£13,857.11 25% OFF
You save £4,619.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,857.11
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,857.11

Why Choose the ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP, order code 1SDA073047R1, is a high-performance SACE Emax 2 air circuit breaker designed for protection, switching and control in demanding low-voltage electrical distribution systems. As part of the advanced ABB Emax 2 E2.2 series, this four-pole withdrawable circuit breaker combines a rated current of 2500 A with the intelligent Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides comprehensive long-time, short-time, instantaneous and earth-fault protection, making the breaker particularly suitable for generator, transformer and installation protection. Its electronic protection platform enables accurate protection settings and supports selective coordination within modern industrial and commercial power-distribution networks.

With a 2500 A rated current and 66 kA short-circuit breaking capacity at 400 V AC, the E2.2N 2500 provides robust protection for high-current electrical systems. The four-pole withdrawable moving-part configuration facilitates isolation and maintenance, while four auxiliary contacts and open/closed circuit-breaker position indication support integration into switchgear control and monitoring systems.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 2500 A rated current for demanding high-current electrical installations.
  • Four-pole configuration for comprehensive circuit switching and protection.
  • Advanced Ekip G Touch LSIG electronic trip unit.
  • LSIG protection provides long-time, short-time, instantaneous and earth-fault protection functions.
  • 66 kA short-circuit breaking capacity at 400 V AC.
  • Withdrawable moving-part design supports convenient isolation and maintenance.
  • Suitable for generator, transformer and general installation protection.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 2500 A rated current.
  • Four-pole air circuit breaker.
  • Ekip G Touch electronic release.
  • LSIG protection functions for comprehensive electrical protection.
  • 1000–2500 A overload release setting range.
  • 66 kA breaking capacity at 400 V AC.
  • Four auxiliary contacts fitted to the circuit breaker.
  • Open/closed circuit-breaker position indication.
  • Withdrawable moving-part configuration for SACE Emax 2 installations.
  • Designed for advanced generator and power-distribution protection.

Advanced Circuit Protection and Power Management

ABB SACE Emax 2 air circuit breakers are engineered to protect low-voltage electrical installations against overloads, short circuits and earth faults while providing dependable switching for high-current distribution systems. The E2.2 platform combines robust interruption technology with intelligent electronic protection, making it suitable for installations where continuity of service, selectivity and accurate fault protection are important.

The Ekip G Touch trip unit is specifically suited to advanced generator and electrical distribution protection. Its LSIG functionality provides adjustable long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, allowing the breaker to be coordinated with other protective devices throughout the electrical network.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Generator protection and generator switchboards.
  • Transformer and installation protection.
  • Industrial power distribution systems.
  • Manufacturing and process-industry electrical systems.
  • Commercial and infrastructure power distribution.
  • Critical power and high-current distribution applications.

Technical Specifications

Series SACE Emax 2 E2.2
Order code / MPN 1SDA073047R1
Product type Air circuit breaker
Rated current 2500 A
Number of poles 4
Short-circuit breaking capacity at 400 V AC 66 kA
Overload release setting range 1000–2500 A
Release unit Ekip G Touch
Protection functions LSIG
Long-time protection Overload protection
Short-time protection Short-circuit protection with time delay
Instantaneous protection Instantaneous short-circuit protection
Earth-fault protection Ground / earth-fault protection
Configuration Withdrawable moving part
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Main circuit connection Connection through separate fixed part
EAN 8015644768973

Frequently Asked Questions

What is the ABB 1SDA073047R1 used for?

The ABB 1SDA073047R1 is a SACE Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems, including generator, transformer and general installation protection applications.

What is the rated current of the E2.2N 2500?

The E2.2N 2500 has a rated current of 2500 A, with an overload release setting range of 1000–2500 A.

What protection functions does the Ekip G Touch LSIG release provide?

The Ekip G Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection for comprehensive protection of low-voltage electrical circuits.

What is the breaking capacity of the ABB 1SDA073047R1?

The E2.2N performance level provides a short-circuit breaking capacity of 66 kA at 400 V AC, making it suitable for demanding high-current distribution systems.

Is the ABB 1SDA073047R1 a fixed or withdrawable breaker?

This model is supplied as a withdrawable moving part for a compatible ABB SACE Emax 2 installation, facilitating circuit isolation, inspection and maintenance within the switchgear assembly.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers combine high-current switching, intelligent electronic protection and flexible power-management capabilities for dependable operation in demanding industrial, commercial, generator and infrastructure electrical distribution systems.