ABB 1SDA073020R1 Emax 2 E2.2N 2000 Ekip G Hi-Touch LSIG four-pole withdrawable air circuit breaker moving part rated at 2000 A with advanced LSIG, generator-specific protection, integrated measurement, power-quality monitoring and 66 kA short-circuit breaking capacity.
£12,336.95
The ABB E2.2N 2000 Ekip G Hi-Touch LSIG 4p WMP, order code 1SDA073020R1, is a high-performance four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. Rated at 2000 A, it combines the E2.2N frame with the advanced Ekip G Hi-Touch LSIG electronic trip unit for demanding low-voltage distribution and generator protection applications.
The Ekip G Hi-Touch LSIG release provides long-time (L), selective short-time (S), instantaneous (I) and earth-fault (G) protection together with generator-specific protection functionality. Its electronic settings provide an overload adjustment range of 800–2000 A, selective short-time adjustment from 1200–20000 A and instantaneous adjustment from 3000–30000 A, supporting coordinated protection across demanding power systems.
The E2.2N frame provides an ultimate short-circuit breaking capacity of 66 kA up to 690 V AC. The Hi-Touch platform also incorporates Ekip Measuring Pro and Network Analyzer functionality for advanced electrical measurement and power-quality supervision, while the withdrawable construction supports efficient inspection, servicing and replacement within compatible Emax 2 switchboards.
The ABB SACE Emax 2 platform is designed to protect and manage high-current low-voltage electrical systems. The Ekip G Hi-Touch LSIG release combines long-time overload, selective short-time, instantaneous and earth-fault protection with generator-specific protection functionality, making the breaker suitable for both conventional distribution networks and power-generation applications.
Beyond circuit protection, Ekip Measuring Pro and the integrated Network Analyzer provide advanced electrical measurement and power-quality supervision. Combined with the E2.2N frame's 66 kA breaking capacity up to 690 V AC and service-friendly withdrawable construction, the 1SDA073020R1 provides a comprehensive solution where generator protection, selectivity, system monitoring and maintainability are key requirements.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA073020R1 |
| EAN | 8015644768706 |
| Product group | Emax 2 Air Circuit Breaker |
| Product type | Air circuit breaker moving part |
| Frame | E2.2 |
| Performance level | N |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Number of poles | 4P |
| Neutral pole current | 100% of Iu |
| Current type | AC |
| Installation | Withdrawable, moving part |
| Version | W |
| Main-circuit connection | Connection at separate chassis part |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | L, S, I and G plus generator-specific protection |
| Overload release adjustment | 800–2000 A |
| Selective short-time release adjustment | 1200–20000 A |
| Instantaneous release adjustment | 3000–30000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated frequency | 50 / 60 Hz |
| Icu at 380 V AC | 66 kA |
| Icu at 400 / 415 V AC | 66 kA |
| Icu at 440 V AC | 66 kA |
| Icu at 500 / 525 V AC | 66 kA |
| Icu at 690 V AC | 66 kA |
| Integrated earth-fault protection | Yes |
| Measurement module | Ekip Measuring Pro |
| Power-quality monitoring | Network Analyzer |
| Auxiliary contacts | 4 change-over contacts |
| Breaker position indication | Open / closed |
| Control element | Push button |
| Motor drive integrated | No |
| Motor drive | Optional |
| Degree of protection | IP30 |
| Connecting capacity | 1800 mm² |
| Power loss | 450 W |
| Electrical durability | 10,000 cycles at ≤440 V; 8,000 cycles at 500–690 V |
| Maximum electrical operating frequency | 30 cycles per hour |
| Mechanical durability | 25,000 cycles |
| Maximum mechanical operating frequency | 60 cycles per hour |
| Dimensions (W × H × D) | 407 × 425 × 383 mm |
| Product net weight | 55 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA073020R1 is an Emax 2 E2.2N four-pole withdrawable air circuit breaker moving part rated at 2000 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.
The Ekip G Hi-Touch LSIG provides long-time overload (L), selective short-time (S), instantaneous short-circuit (I) and earth-fault (G) protection together with generator-specific protection functions and advanced electrical monitoring.
The overload release is adjustable from 800–2000 A, selective short-time protection from 1200–20000 A and instantaneous protection from 3000–30000 A.
The E2.2N 2000 provides an ultimate short-circuit breaking capacity of 66 kA at 380 V, 400 / 415 V, 440 V, 500 / 525 V and 690 V AC.
Yes. The Ekip G Hi-Touch LSIG release includes generator-specific protection functions together with LSIG circuit protection, Ekip Measuring Pro and Network Analyzer functionality for demanding generation and distribution systems.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-specific functionality, electrical measurement, power-quality monitoring and service-friendly withdrawable construction for dependable management of demanding low-voltage power systems.