ABB 1SDA073016R1 is an Emax 2 E2.2N 2000 A four-pole withdrawable air circuit breaker moving part with an Ekip Touch LSIG electronic trip unit providing long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection for high-current low-voltage power distribution systems.
£9,340.42
The ABB 1SDA073016R1 is an Emax 2 E2.2N 2000 A four-pole air circuit breaker moving part designed for reliable protection, switching and isolation in high-current low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 range, it combines robust withdrawable construction with the advanced Ekip Touch LSIG electronic trip unit.
The Ekip Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection. Protection parameters can be configured through the touch-sensitive display, providing intuitive adjustment and comprehensive electronic protection for demanding power-distribution applications.
With a rated uninterrupted current of 2000 A, a four-pole configuration and an ultimate short-circuit breaking capacity of 66 kA from 380–690 V AC, the 1SDA073016R1 provides consistent fault-interruption performance across a broad operating-voltage range. Its withdrawable moving-part construction enables integration with a compatible Emax 2 E2.2 fixed part and supports efficient inspection, servicing and replacement within switchgear assemblies.
The ABB Emax 2 E2.2N provides switching, isolation and electronic protection for high-current low-voltage distribution circuits. The 1SDA073016R1 delivers an ultimate short-circuit breaking capacity of 66 kA at 380 V, 400/415 V, 440 V, 500/525 V and 690 V AC, making it suitable for main switchboards and distribution systems where consistent fault-interruption performance is required across a wide operating-voltage range.
The Ekip Touch LSIG trip unit combines adjustable long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection. This comprehensive protection package helps safeguard conductors and equipment against multiple fault conditions while supporting selective coordination within the distribution network. Combined with the E2.2N frame and withdrawable architecture, the 1SDA073016R1 provides a flexible solution for demanding 2000 A distribution applications.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2 |
| Performance level | N |
| ABB order code / MPN | 1SDA073016R1 |
| Product type | Air circuit breaker moving part |
| Rated current | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Number of poles | 4 |
| Trip unit | Ekip Touch LSIG |
| Trip unit type | Solid-state electronic protection release |
| Protection functions | LSIG – long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection |
| Overload protection adjustment | 0.4–1 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection adjustment | 0.1–1 × In |
| Integrated earth-fault protection | Yes |
| Protection interface | Touch-sensitive display |
| Ultimate short-circuit breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50/60 Hz |
| Current type | AC |
| Execution | Withdrawable moving part (WMP) |
| Main-circuit connection | Connection via separate compatible E2.2 fixed part |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Installation | Withdrawable |
| Standard | IEC 60947-2 |
| EAN | 8015644768669 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA073016R1 is an Emax 2 E2.2N air circuit breaker moving part designed for switching, isolation and electronic protection of high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure installations.
The E2.2N 2000 has a rated uninterrupted current of 2000 A and is supplied in a four-pole configuration.
The Ekip Touch LSIG electronic trip unit provides long-time overload protection (L), short-time selective short-circuit protection (S), instantaneous short-circuit protection (I) and earth-fault protection (G). Protection parameters are configured through its touch-sensitive display.
The E2.2N 2000 provides an ultimate short-circuit breaking capacity of 66 kA at 380 V, 400/415 V, 440 V, 500/525 V and 690 V AC, providing consistent fault-interruption capability across its operating-voltage range.
The 1SDA073016R1 is the withdrawable moving part (WMP) of an ABB Emax 2 circuit-breaker system. It is designed for installation with a compatible E2.2 fixed part, allowing the breaker to be withdrawn for inspection, servicing or replacement.
ABB SACE Emax 2 air circuit breakers provide advanced protection and control for modern low-voltage power distribution systems, combining robust short-circuit performance, intelligent electronic protection and flexible withdrawable switchgear integration.
We use cookies