ABB 1SDA073012R1 SACE Emax 2 E2.2N 2000 A four-pole withdrawable air circuit breaker moving part with Ekip Dip LSI electronic protection for selective high-current low-voltage power distribution.
£8,741.11
The ABB 1SDA073012R1 is a SACE Emax 2 E2.2N air circuit breaker moving part rated at 2000 A, designed for reliable protection, switching and isolation in high-current low-voltage electrical distribution systems. This four-pole withdrawable model incorporates the Ekip Dip LSI electronic trip unit, providing adjustable long-time, short-time and instantaneous protection.
As part of the ABB SACE Emax 2 range, the E2.2N combines robust short-circuit performance with configurable electronic protection. The Ekip Dip LSI release uses DIP switches for straightforward protection adjustment, while its short-time function supports selective coordination between upstream and downstream protective devices.
With a rated uninterrupted current of 2000 A, a four-pole configuration and rated operational voltage up to 690 V AC, this E2.2N provides an ultimate short-circuit breaking capacity of 66 kA from 380 to 690 V AC. Its withdrawable moving-part construction supports efficient inspection, servicing and replacement in maintainable switchboard installations.
The ABB SACE Emax 2 E2.2N platform provides dependable switching and protection for high-current low-voltage distribution networks. Its 66 kA ultimate short-circuit breaking capacity and short-time withstand capability support robust fault interruption and selective protection in main distribution circuits.
The Ekip Dip LSI release provides adjustable long-time protection against sustained overloads, short-time protection for selective fault coordination and instantaneous protection against severe short circuits. This combination enables engineers to coordinate protective devices so that faults can be isolated close to their source while helping maintain continuity in unaffected sections of the installation.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA073012R1 |
| EAN | 8015644768621 |
| Product type | Air circuit breaker moving part |
| Frame | E2.2N |
| Rated uninterrupted current | 2000 A |
| Number of poles | 4 |
| Neutral pole current | 100% Iu |
| Current type | AC |
| Trip unit | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | Long-time (L), short-time (S), instantaneous (I) |
| Overload protection adjustment | 0.4–1 × In (800–2000 A) |
| Short-time protection adjustment | 0.6–10 × In (1200–20000 A) |
| Instantaneous protection adjustment | 1.5–15 × In (3000–30000 A) |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Ultimate breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 400/415 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Short-time withstand current (Icw), 1 s | 66 kA |
| Installation | Withdrawable |
| Configuration | Moving part |
| Auxiliary contacts | 4 change-over contacts |
| Breaker position indication | Open/closed |
| Integrated ground-fault protection | No |
| Power loss | 450 W |
| Electrical durability | 10,000 cycles at Ue ≤ 440 V; 8,000 cycles at 500–690 V |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 407 × 425 × 383 mm |
| Product net weight | 55 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA073012R1 is a 2000 A four-pole air circuit breaker moving part designed for switching, isolation and protection of high-current low-voltage distribution systems against overloads and short circuits.
The breaker incorporates an Ekip Dip LSI electronic trip unit, providing adjustable long-time, short-time and instantaneous protection with settings configured through DIP switches.
The E2.2N 2000 provides an ultimate short-circuit breaking capacity of 66 kA at 380 V AC, 400/415 V AC, 440 V AC, 500/525 V AC and 690 V AC.
No. This model uses the Ekip Dip LSI release, which provides long-time, short-time and instantaneous protection. Emax 2 models equipped with LSIG releases add integrated ground-fault protection.
The 1SDA073012R1 is a withdrawable moving part for the SACE Emax 2 E2.2N platform, allowing convenient removal from the corresponding fixed part for inspection, maintenance or replacement.
ABB SACE Emax 2 air circuit breakers combine high-current switching capability, selective electronic protection and maintainable withdrawable construction for dependable modern low-voltage power distribution.