1SDA072990R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker 1600 A

1SDA072990R1 ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker 1600 A

ABB 1SDA072990R1 E2.2S 1600 Ekip G Hi-Touch LSIG 4p WMP is a 1600 A four-pole withdrawable Emax 2 air circuit breaker moving part with advanced generator-oriented LSIG protection, measurement and monitoring capabilities.

SKU: 1SDA072990R1MPN: 1SDA072990R1
Price
List Price £14,851.12 ex VAT
Your Price (ex VAT) Save 25%
£11,138.34 25% OFF
You save £3,712.78 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,138.34
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,138.34

Why Choose the ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2S 1600 Ekip G Hi-Touch LSIG 4p WMP, order code 1SDA072990R1, is a high-performance four-pole air circuit breaker (ACB) moving part designed for advanced protection, switching and isolation in demanding low-voltage power distribution and generator applications. Part of the ABB SACE Emax 2 series, it combines a 1600 A rated uninterrupted current with the E2.2S performance level and sophisticated generator-oriented electronic protection.

This Emax 2 circuit breaker is equipped with the Ekip G Hi-Touch LSIG electronic trip unit. The generator-focused Ekip G platform combines long-time, short-time, instantaneous and ground-fault protection with the advanced protection, measurement and monitoring capabilities of ABB's Hi-Touch architecture, making it particularly suitable for installations requiring comprehensive electrical protection and supervision.

The E2.2S 1600 provides a rated ultimate short-circuit breaking capacity of 85 kA at 400 V AC and a rated operational voltage of 690 V AC. Its four-pole withdrawable moving-part (WMP) construction is designed for use with the corresponding Emax 2 fixed part, supporting convenient isolation, inspection, servicing and replacement within maintainable power distribution assemblies.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker technology for demanding low-voltage electrical systems.
  • 1600 A rated uninterrupted current for high-current distribution and generator applications.
  • Four-pole configuration for comprehensive three-phase and neutral switching.
  • Ekip G Hi-Touch LSIG electronic trip unit with generator-oriented protection capabilities.
  • Long-time, short-time, instantaneous and ground-fault protection.
  • 85 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Rated operational voltage of 690 V AC.
  • Adjustable electronic protection supports selective coordination within complex electrical systems.
  • Advanced Hi-Touch architecture supports protection, measurement and electrical system monitoring.
  • Withdrawable construction supports efficient isolation, servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1600 A rated uninterrupted current.
  • Four-pole air circuit breaker moving part.
  • Ekip G Hi-Touch LSIG solid-state electronic protection release.
  • Generator-oriented electronic protection platform.
  • Long-time overload, short-time, instantaneous and ground-fault protection functions.
  • 85 kA Icu at 400 V AC.
  • Rated voltage of 690 V AC.
  • Overload protection adjustable from 640–1600 A.
  • Short-time delayed short-circuit protection adjustable from 960–16000 A.
  • Instantaneous short-circuit protection adjustable from 2400–24000 A.
  • Integrated earth-fault protection.
  • Four auxiliary changeover contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.
  • IP30 degree of protection.
  • Withdrawable moving-part construction for maintainable power distribution assemblies.

Advanced Generator and Power Distribution Protection

The ABB Emax 2 E2.2S platform provides switching, isolation and electronic protection for high-current low-voltage circuits. With a 1600 A rated uninterrupted current and 85 kA short-circuit breaking capacity at 400 V AC, this model is engineered for demanding switchboards and electrical systems where substantial prospective fault currents may be present.

The Ekip G Hi-Touch LSIG trip unit combines generator-oriented protection capabilities with long-time overload, short-time, instantaneous and ground-fault protection. Its advanced electronic architecture supports sophisticated protection and monitoring requirements, while the withdrawable Emax 2 construction facilitates isolation, maintenance and continuity strategies in critical electrical installations.

Typical Applications

  • Generator protection and generator distribution systems.
  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial and infrastructure power distribution.
  • Main incoming and high-current feeder protection.
  • Emergency and standby power systems.
  • Industrial switchgear and power distribution assemblies.
  • Distribution systems requiring integrated ground-fault protection.
  • Systems requiring selective overload and short-circuit protection.
  • Critical electrical installations requiring advanced protection and monitoring.
  • Withdrawable switchgear systems requiring convenient maintenance and isolation.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA072990R1
EAN 8015644768409
Product type Air circuit breaker moving part
Product group Emax2 Air Circuit Breaker
Frame E2.2
Performance level S
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic
Protection functions Long-time (L), short-time (S), instantaneous (I), ground-fault (G)
Overload release adjustment range 640–1600 A
Short-time delayed short-circuit release adjustment range 960–16000 A
Instantaneous short-circuit release adjustment range 2400–24000 A
Integrated earth-fault protection Yes
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Rated operational voltage 690 V AC
Current type AC
Auxiliary changeover contacts 4
Circuit-breaker position indication Open/closed
Integrated undervoltage release No
Integrated motor drive No
Optional motor drive Yes
Degree of protection IP30
Main circuit connection Connection at separate chassis part
Standard IEC
Execution Withdrawable
Configuration Moving part of withdrawable circuit breaker (WMP)
Product net width 407 mm
Product net height 425 mm
Product net depth 383 mm
Product net weight approx. 55 kg

Frequently Asked Questions

What is the ABB 1SDA072990R1 used for?

The ABB 1SDA072990R1 is a 1600 A four-pole air circuit breaker moving part designed for advanced protection, switching and isolation in demanding low-voltage power distribution and generator applications.

What is the rated current of the ABB E2.2S 1600?

The ABB E2.2S 1600 has a rated uninterrupted current of 1600 A.

What protection does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG electronic trip unit provides generator-oriented protection together with long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection, plus advanced measurement and monitoring capabilities.

What is the breaking capacity of the ABB E2.2S 1600?

The E2.2S 1600 provides a rated ultimate short-circuit breaking capacity of 85 kA at 400 V AC and has a rated operational voltage of 690 V AC.

Is the ABB 1SDA072990R1 a withdrawable circuit breaker?

Yes. The 1SDA072990R1 is the four-pole withdrawable moving part (WMP) of an ABB SACE Emax 2 E2.2S 1600 air circuit breaker and is designed for use with the corresponding withdrawable fixed part.

Trusted Generator and Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-performance low-voltage circuit protection with advanced electronic trip technology, while the Ekip G Hi-Touch platform provides generator-oriented protection, measurement and monitoring capabilities for demanding electrical systems.