ABB 1SDA072973R1 SACE Emax 2 E2.2N 1600 A four-pole withdrawable air circuit breaker with Ekip Dip LSIG electronic protection for comprehensive low-voltage power distribution protection.
£7,571.74
The ABB 1SDA072973R1 is a high-performance SACE Emax 2 E2.2N air circuit breaker rated at 1600 A, designed for dependable protection, switching and isolation in low-voltage electrical distribution systems. This four-pole withdrawable moving-part breaker incorporates the Ekip Dip LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection.
As part of the ABB SACE Emax 2 range, the E2.2N combines robust short-circuit performance with configurable electronic protection and straightforward switchboard integration. Protection settings on the Ekip Dip LSIG release are adjusted using DIP switches, enabling engineers to coordinate overload, selective short-circuit, instantaneous and earth-fault protection for demanding distribution applications.
With a rated uninterrupted current of 1600 A, a four-pole configuration and rated operational voltage up to 690 V AC, this E2.2N breaker provides an ultimate short-circuit breaking capacity of 66 kA from 380 V AC through 690 V AC. Its withdrawable moving-part construction facilitates inspection, servicing and replacement in maintainable switchboard installations.
Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical networks against overloads, short circuits and ground faults while providing dependable switching and isolation of high-current circuits. The E2.2N platform combines 66 kA short-circuit breaking capability with configurable electronic protection for demanding main distribution and feeder applications.
The Ekip Dip LSIG release combines adjustable long-time, selective short-time, instantaneous and ground-fault protection. These functions support coordinated protection throughout the electrical network, helping isolate faults close to their source while reducing unnecessary interruption to unaffected sections of an installation.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA072973R1 |
| EAN | 8015644768232 |
| Product type | Air circuit breaker |
| Frame | E2.2N |
| Rated uninterrupted current | 1600 A |
| Number of poles | 4 |
| Current type | AC |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time (L), short-time (S), instantaneous (I), ground fault (G) |
| Overload protection adjustment | 0.4–1 × In (640–1600 A) |
| Short-time protection adjustment | 0.6–10 × In (960–16000 A) |
| Instantaneous protection adjustment | 1.5–15 × In (2400–24000 A) |
| Ground-fault protection adjustment | 0.1–1 × In |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Ultimate breaking capacity (Icu) at 380 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 400/415 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 500/525 V AC | 66 kA |
| Ultimate breaking capacity (Icu) at 690 V AC | 66 kA |
| Installation | Withdrawable |
| Configuration | Moving part |
| Main-circuit connection | Connection at separate chassis part |
| Auxiliary contacts | 4 change-over contacts |
| Integrated earth-fault protection | Yes |
| Degree of protection | IP30 |
| Electrical durability | 12,000 cycles at Ue ≤ 440 V; 10,000 cycles at 500–690 V |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 407 × 425 × 383 mm |
| Product net weight | 55 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA072973R1 is a 1600 A air circuit breaker used for switching, isolation and protection of low-voltage electrical distribution systems against overloads, short circuits and ground faults.
The breaker incorporates an Ekip Dip LSIG electronic trip unit, providing configurable long-time, short-time, instantaneous and ground-fault protection.
The E2.2N 1600 provides an ultimate short-circuit breaking capacity of 66 kA at 380 V AC, 400/415 V AC, 440 V AC, 500/525 V AC and 690 V AC.
Yes. The G function of the Ekip Dip LSIG release provides integrated ground-fault protection in addition to long-time, short-time and instantaneous protection.
The 1SDA072973R1 is a withdrawable moving-part version of the SACE Emax 2 E2.2N, designed for connection to a separate chassis part and convenient withdrawal for inspection, servicing or replacement.
ABB SACE Emax 2 air circuit breakers combine dependable high-current switching, configurable electronic protection and maintainable withdrawable construction for modern low-voltage power distribution systems.