1SDA072960R1 ABB E2.2H 1250 Ekip G Hi-Touch LSIG 4P WMP Air Circuit Breaker

1SDA072960R1 ABB E2.2H 1250 Ekip G Hi-Touch LSIG 4P WMP Air Circuit Breaker

ABB 1SDA072960R1 Emax 2 E2.2H 1250 Ekip G Hi-Touch LSIG four-pole withdrawable air circuit breaker moving part rated at 1250 A with advanced LSIG, generator-oriented protection and high short-circuit performance.

SKU: 1SDA072960R1MPN: 1SDA072960R1
Price
List Price £13,876.61 ex VAT
Your Price (ex VAT) Save 25%
£10,407.46 25% OFF
You save £3,469.15 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £10,407.46
Trade pricing is personalised to your account

Manufacturer Lead Time

£10,407.46

Why Choose the ABB E2.2H 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2H 1250 Ekip G Hi-Touch LSIG 4p WMP, order code 1SDA072960R1, is a high-performance four-pole withdrawable air circuit breaker moving part from the ABB SACE Emax 2 range. Designed for demanding low-voltage distribution and generator applications, it combines a 1250 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release combines long-time (L), selective short-time (S), instantaneous (I) and earth-fault (G) protection with advanced generator-oriented protection functions. The Hi-Touch platform also supports sophisticated electrical measurement and Network Analyzer functionality, making the breaker particularly suitable for systems requiring protection, generator supervision and detailed power-quality monitoring.

The E2.2H high-breaking-capacity frame provides an ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 85 kA at 690 V AC. Its withdrawable construction facilitates inspection, servicing and replacement within compatible Emax 2 switchgear, while the breaker is supplied with four auxiliary contacts and open/closed position indication.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage systems.
  • 1250 A rated uninterrupted current for industrial, infrastructure and power-generation applications.
  • Ekip G Hi-Touch LSIG electronic trip unit with advanced generator-oriented protection functionality.
  • Comprehensive long-time, selective short-time, instantaneous and earth-fault protection.
  • High 100 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Maintains 85 kA breaking capacity at 690 V AC for demanding higher-voltage LV systems.
  • Advanced electrical measurement and Network Analyzer functionality support system supervision and power-quality monitoring.
  • Withdrawable four-pole construction supports convenient switchboard servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E2.2H air circuit breaker moving part.
  • 1250 A rated uninterrupted current.
  • 4-pole configuration.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Long-time L overload protection.
  • Selective short-time S short-circuit protection.
  • Instantaneous I short-circuit protection.
  • Integrated earth-fault G protection.
  • Generator-oriented protection and monitoring functions.
  • Overload release setting range of 500–1250 A.
  • Short-time delayed short-circuit release setting range of 750–12500 A.
  • Instantaneous short-circuit release setting range of 1875–18750 A.
  • 100 kA Icu at 415 V AC.
  • 85 kA Icu at 690 V AC.
  • Integrated Network Analyzer for power-quality monitoring.
  • Supplied with four auxiliary contacts and breaker open/closed position indication.

Advanced Generator and Distribution System Protection

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage systems against overloads, short circuits and earth faults. The Ekip G Hi-Touch LSIG release combines adjustable L, S, I and G functions with generator-oriented protection capabilities, enabling comprehensive protection for distribution networks and generating installations.

The Hi-Touch platform extends conventional circuit protection with advanced electrical measurement and Network Analyzer functionality for real-time power-quality supervision. Combined with the E2.2H frame's 100 kA breaking capacity at 415 V AC and service-friendly withdrawable construction, the 1SDA072960R1 provides a powerful solution for switchboards where high fault performance, generator protection, selectivity and detailed electrical monitoring are required.

Typical Applications

  • Generator and generating-set protection.
  • Low-voltage main distribution switchboards.
  • Industrial power-generation and distribution systems.
  • Transformer and installation protection.
  • Emergency and standby power systems.
  • Critical infrastructure and commercial electrical distribution.
  • High fault-level feeder and incomer protection.
  • Applications requiring integrated earth-fault protection and power-quality monitoring.

Technical Specifications

Series SACE Emax 2
Order code 1SDA072960R1
EAN 8015644768102
Product type Air circuit breaker moving part
Application Transformer, generator and installation protection
Frame E2.2
Performance level H
Rated uninterrupted current (Iu) 1250 A
Number of poles 4P
Current type AC
Installation Withdrawable, moving part
Main-circuit connection Via separate fixed part
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic
Protection functions L, S, I and G plus generator-oriented protection
Overload release current setting 500–1250 A
Short-time delayed short-circuit release setting 750–12500 A
Instantaneous short-circuit release setting 1875–18750 A
Rated voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Integrated earth-fault protection Yes
Power-quality monitoring Network Analyzer
Auxiliary contacts 4
Breaker position indication Open / closed
Withdrawable construction Yes
DIN-rail mounting No
Width 407 mm
Depth 383 mm
Standards / approvals IEC
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA072960R1?

The ABB 1SDA072960R1 is an Emax 2 E2.2H four-pole withdrawable air circuit breaker moving part rated at 1250 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG provides long-time overload (L), selective short-time (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced generator-oriented protection and monitoring functions.

What are the protection setting ranges of the ABB E2.2H 1250?

The overload release is adjustable from 500–1250 A, the short-time delayed short-circuit release from 750–12500 A, and the instantaneous short-circuit release from 1875–18750 A.

What is the breaking capacity of the ABB E2.2H 1250?

The E2.2H provides an ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 85 kA at 690 V AC, providing high fault-interruption capability for demanding low-voltage systems.

Is the ABB 1SDA072960R1 suitable for generator protection?

Yes. The Ekip G Hi-Touch LSIG trip unit combines generator-oriented protection with LSIG circuit protection, advanced electrical measurement and Network Analyzer functionality for demanding generation and distribution applications.

Trusted ABB Emax 2 Generator and Distribution Protection

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-oriented functionality, high short-circuit performance and sophisticated electrical monitoring with service-friendly withdrawable construction for demanding low-voltage power systems.