1SDA072950R1 ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

1SDA072950R1 ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA072950R1 SACE Emax 2 E2.2S 1250 A four-pole withdrawable air circuit breaker with Ekip G Hi-Touch LSIG electronic protection for advanced generator and low-voltage power distribution applications.

SKU: 1SDA072950R1MPN: 1SDA072950R1
Price
List Price £13,194.50 ex VAT
Your Price (ex VAT) Save 25%
£9,895.88 25% OFF
You save £3,298.63 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,895.88
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,895.88

Why Choose the ABB E2.2S 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072950R1 is a high-performance SACE Emax 2 E2.2S air circuit breaker rated at 1250 A, designed for advanced generator protection, monitoring and control in low-voltage electrical systems. This four-pole withdrawable moving-part breaker incorporates the sophisticated Ekip G Hi-Touch LSIG electronic trip unit, combining long-time, short-time, instantaneous and ground-fault protection with dedicated generator protection functions.

As part of the advanced ABB SACE Emax 2 range, the E2.2S combines high short-circuit performance with comprehensive electronic protection and advanced electrical measurement. The Ekip G Hi-Touch platform is specifically suited to generator applications and provides an intuitive touchscreen interface, enhanced protection functions and power-quality monitoring capabilities for critical electrical networks.

With a rated uninterrupted current of 1250 A, a four-pole configuration and rated operational voltage up to 690 V AC, this E2.2S breaker is suitable for substantial generator and low-voltage distribution systems. The S performance class provides an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC, while its withdrawable construction facilitates inspection, servicing and replacement.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for generator and distribution protection.
  • 1250 A rated uninterrupted current for high-current electrical systems.
  • Four-pole configuration suitable for three-phase systems with neutral switching.
  • Ekip G Hi-Touch LSIG electronic trip unit with comprehensive circuit and generator protection functions.
  • 85 kA ultimate breaking capacity at 400/415 V AC for demanding fault-current conditions.
  • Advanced measurement and power-quality analysis support intelligent generator and network management.

Key Features

  • ABB SACE Emax 2 E2.2S frame.
  • 1250 A rated current.
  • 4-pole configuration.
  • Ekip G Hi-Touch LSIG electronic protection release.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Dedicated advanced protection functions for generator applications.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Withdrawable moving-part construction for maintainable switchboard installations.

Advanced Generator and Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection against overloads, short circuits and ground faults in low-voltage electrical networks. The E2.2S platform combines high breaking performance with short-time withstand capability, supporting selective protection and reliable operation in demanding generator and distribution applications.

The Ekip G Hi-Touch LSIG release extends conventional LSIG protection with functions developed for generator applications, together with advanced electrical measurement and power-quality analysis. These capabilities help engineers protect generating equipment, coordinate protective devices and monitor critical electrical parameters throughout modern power systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Emergency and standby power generation systems.
  • Main low-voltage switchboards and distribution boards.
  • Industrial power distribution systems.
  • Manufacturing plants and process facilities.
  • Critical electrical networks requiring advanced protection and monitoring.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072950R1
Product type Air circuit breaker
Frame E2.2S
Rated uninterrupted current 1250 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Protection functions Long-time (L), short-time (S), instantaneous (I), ground fault (G)
Application Generator and low-voltage distribution protection
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 400/415 V AC 85 kA
Ultimate breaking capacity (Icu) at 440 V AC 85 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate breaking capacity (Icu) at 690 V AC 66 kA
Service breaking capacity (Ics) 100% of Icu
Short-time withstand current (Icw), 1 s 66 kA
Short-time withstand current (Icw), 3 s 50 kA
Frequency 50 / 60 Hz
Installation Withdrawable
Configuration Moving part
Integrated ground-fault protection Yes
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072950R1 used for?

The ABB 1SDA072950R1 is a 1250 A air circuit breaker designed for generator and low-voltage distribution protection, providing switching, isolation and electronic protection against overloads, short circuits and ground faults.

What protection unit is fitted to the ABB 1SDA072950R1?

The breaker incorporates an Ekip G Hi-Touch LSIG electronic trip unit, combining long-time, short-time, instantaneous and ground-fault protection with advanced generator protection functions.

What is the breaking capacity of the E2.2S 1250?

The E2.2S 1250 provides an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC.

Is the Ekip G Hi-Touch suitable for generator protection?

Yes. The Ekip G Hi-Touch release is designed with advanced protection functions for generator applications while also providing LSIG circuit protection, measurement and power-quality monitoring capabilities.

Is the ABB 1SDA072950R1 a fixed or withdrawable breaker?

The 1SDA072950R1 is a withdrawable moving-part version of the SACE Emax 2 E2.2S, enabling convenient withdrawal from the corresponding fixed part for inspection, servicing or replacement.

Trusted Generator and Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced generator protection and sophisticated electronic monitoring technologies for dependable low-voltage power systems.