1SDA072938R1 ABB E2.2N 1250 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker 1250 A

1SDA072938R1 ABB E2.2N 1250 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker 1250 A

ABB 1SDA072938R1 E2.2N 1250 Ekip Hi-Touch LSI 4p WMP is a 1250 A four-pole withdrawable Emax 2 air circuit breaker moving part with advanced electronic long-time, short-time and instantaneous protection for low-voltage power distribution systems.

SKU: 1SDA072938R1MPN: 1SDA072938R1
Price
List Price £11,537.89 ex VAT
Your Price (ex VAT) Save 25%
£8,653.42 25% OFF
You save £2,884.47 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,653.42
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,653.42

Why Choose the ABB E2.2N 1250 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker?

The ABB E2.2N 1250 Ekip Hi-Touch LSI 4p WMP, order code 1SDA072938R1, is a high-performance four-pole air circuit breaker (ACB) moving part designed for advanced protection, switching and isolation in low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 series, it combines a 1250 A rated uninterrupted current with sophisticated electronic protection and measurement capabilities for demanding industrial, commercial and infrastructure power distribution applications.

This Emax 2 circuit breaker is equipped with the Ekip Hi-Touch LSI electronic trip unit, providing long-time, short-time and instantaneous overcurrent protection. The advanced Hi-Touch platform offers touchscreen-based configuration and enhanced protection, measurement and power-management capabilities, making it particularly suitable for electrical systems where accurate monitoring, selective coordination and flexible system integration are required.

The E2.2N 1250 provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC, with a rated short-time withstand current of 66 kA for 1 s. Its four-pole withdrawable moving-part (WMP) construction is designed for use with the corresponding Emax 2 fixed part, facilitating isolation, inspection, servicing and replacement in critical power distribution systems.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1250 A rated uninterrupted current for high-current electrical installations.
  • Four-pole configuration with 100% neutral-pole current capability.
  • Ekip Hi-Touch LSI electronic trip unit provides advanced long-time, short-time and instantaneous protection.
  • 66 kA ultimate short-circuit breaking capacity at 400–690 V AC.
  • 66 kA short-time withstand current for 1 s and 50 kA for 3 s.
  • Advanced measurement and monitoring capabilities support intelligent power management.
  • Withdrawable construction supports efficient isolation, inspection and maintenance.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1250 A rated uninterrupted current.
  • Four-pole air circuit breaker moving part.
  • Ekip Hi-Touch LSI electronic protection trip unit.
  • Long-time, short-time and instantaneous overcurrent protection functions.
  • 66 kA Icu at 400–690 V AC.
  • 100% Ics/Icu service short-circuit breaking performance.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.
  • Rated operational voltage up to 690 V AC.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100% neutral-pole current capability.
  • Four auxiliary changeover contacts and switched-off indication.
  • Withdrawable moving-part construction for maintainable power distribution assemblies.

Advanced Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB Emax 2 E2.2N provide switching, isolation and overcurrent protection for high-current low-voltage distribution circuits. The E2.2N performance level combines a 66 kA short-circuit breaking capacity with substantial short-time withstand capability, helping protect switchboards, conductors and downstream electrical equipment during overload and fault conditions.

The Ekip Hi-Touch LSI trip unit provides advanced long-time protection against sustained overloads, short-time protection for selective fault coordination and instantaneous protection against severe short circuits. Combined with the withdrawable Emax 2 architecture and advanced monitoring capabilities, these functions make the breaker particularly suitable for installations where protection selectivity, electrical performance, system availability and maintainability are important.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial electrical distribution systems.
  • Commercial and infrastructure power distribution.
  • Main incoming and high-current feeder protection.
  • Motor control centres and industrial switchgear assemblies.
  • Distribution systems requiring advanced protection and monitoring.
  • Installations requiring selective short-circuit protection.
  • Withdrawable switchgear systems requiring convenient maintenance and isolation.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA072938R1
EAN 8015644767884
Product type Air circuit breaker moving part
Product group Emax2 Air Circuit Breaker
Frame E2.2
Performance level N
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Number of poles 4
Neutral pole current 100% Iu
Trip unit Ekip Hi-Touch LSI
Release type Electronic
Protection functions Long-time (L), short-time (S), instantaneous (I)
Rated ultimate short-circuit breaking capacity (Icu) at 400–690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) at 380–690 V AC 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 12 kV
Current type AC
Integrated earth-fault protection No
Auxiliary contacts 4 changeover contacts
Switched-off indication Yes
Integrated motor drive No
Motor drive Optional
Power loss 176 W
Electrical durability 15,000 cycles
Mechanical durability 25,000 cycles
Degree of protection IP30
Execution Withdrawable
Configuration Moving part of withdrawable circuit breaker (WMP)
Dimensions (H × W × D) approx. 383 × 407 × 383 mm
Weight approx. 55 kg

Frequently Asked Questions

What is the ABB 1SDA072938R1 used for?

The ABB 1SDA072938R1 is a 1250 A four-pole air circuit breaker moving part used for advanced protection, switching and isolation in low-voltage industrial, commercial and infrastructure power distribution systems.

What is the rated current of the E2.2N 1250?

The E2.2N 1250 has a rated uninterrupted current of 1250 A.

What protection does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI trip unit provides long-time overload protection, short-time short-circuit protection and instantaneous short-circuit protection, together with advanced monitoring and measurement capabilities.

What is the breaking capacity of the ABB E2.2N 1250?

The E2.2N provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC and a rated short-time withstand current of 66 kA for 1 s.

Is the ABB 1SDA072938R1 a withdrawable circuit breaker?

Yes. The 1SDA072938R1 is the four-pole withdrawable moving part (WMP) of an ABB SACE Emax 2 E2.2N 1250 air circuit breaker and is designed for use with the corresponding fixed part.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-performance circuit protection with advanced electronic trip technology, measurement capabilities and flexible integration for demanding low-voltage power distribution systems.