1SDA072935R1 ABB E2.2N 1250 Ekip Touch LSI 4p WMP Air Circuit Breaker

1SDA072935R1 ABB E2.2N 1250 Ekip Touch LSI 4p WMP Air Circuit Breaker

ABB 1SDA072935R1 SACE Emax 2 E2.2N 1250 A four-pole withdrawable air circuit breaker with Ekip Touch LSI electronic protection for demanding low-voltage power distribution systems.

SKU: 1SDA072935R1MPN: 1SDA072935R1
Price
List Price £8,029.76 ex VAT
Your Price (ex VAT) Save 25%
£6,022.32 25% OFF
You save £2,007.44 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,022.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,022.32

Why Choose the ABB E2.2N 1250 Ekip Touch LSI 4p WMP Air Circuit Breaker?

The ABB 1SDA072935R1 is a high-performance SACE Emax 2 E2.2N air circuit breaker rated at 1250 A, designed for reliable protection and control of low-voltage electrical distribution systems. This four-pole withdrawable moving-part breaker incorporates the advanced Ekip Touch LSI electronic trip unit, providing configurable long-time, short-time and instantaneous protection for demanding industrial, commercial and infrastructure installations.

As part of the advanced ABB SACE Emax 2 range, the E2.2N combines dependable short-circuit interruption with sophisticated electronic protection and an intuitive touchscreen interface. The Ekip Touch release enables straightforward configuration of protection parameters and access to electrical information, helping engineers achieve effective selectivity and dependable distribution-system performance.

With a rated uninterrupted current of 1250 A, a four-pole configuration and rated operational voltage of 690 V AC, this E2.2N breaker is suitable for substantial low-voltage distribution systems. It provides an ultimate short-circuit breaking capacity of 66 kA at 400/415 V AC, maintained through 690 V AC, while its withdrawable construction facilitates inspection, servicing and replacement.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1250 A rated uninterrupted current for high-current electrical installations.
  • Four-pole configuration with 100% neutral-pole current capability.
  • Ekip Touch LSI electronic trip unit provides adjustable overload and short-circuit protection.
  • 66 kA ultimate breaking capacity at 400/415 V AC for robust fault protection.
  • Withdrawable moving-part design supports efficient inspection, servicing and breaker replacement.

Key Features

  • ABB SACE Emax 2 E2.2N frame.
  • 1250 A rated current.
  • 4-pole configuration.
  • Ekip Touch LSI electronic protection release.
  • Long-time, short-time and instantaneous protection functions.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA short-time withstand current for 1 s.
  • Four change-over auxiliary contacts and breaker open/closed position indication.

Advanced LSI Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical networks against overloads and short circuits while providing dependable switching and isolation of high-current circuits. The E2.2N platform combines strong fault-interruption capability with short-time withstand performance that supports selective coordination in demanding power distribution systems.

The Ekip Touch LSI release combines adjustable long-time, selective short-time and instantaneous protection with an intuitive touchscreen interface. Configurable protection settings enable coordination with upstream and downstream protective devices, helping isolate faults selectively while minimising unnecessary interruption to unaffected sections of an electrical installation.

Typical Applications

  • Main low-voltage switchboards and distribution boards.
  • Industrial power distribution systems.
  • Commercial buildings and infrastructure installations.
  • Manufacturing plants and process facilities.
  • Transformer secondary and main incoming protection.
  • High-current feeders requiring selective electronic circuit protection.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA072935R1
Product type Air circuit breaker
Frame E2.2N
Rated uninterrupted current 1250 A
Number of poles 4
Neutral pole current 100% Iu
Trip unit Ekip Touch LSI
Protection functions Long-time (L), short-time (S), instantaneous (I)
Overload protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 380 V AC 66 kA
Ultimate breaking capacity (Icu) at 400/415 V AC 66 kA
Ultimate breaking capacity (Icu) at 440 V AC 66 kA
Ultimate breaking capacity (Icu) at 500/525 V AC 66 kA
Ultimate breaking capacity (Icu) at 690 V AC 66 kA
Service breaking capacity (Ics) 100% of Icu
Short-time withstand current (Icw), 1 s 66 kA
Short-time withstand current (Icw), 3 s 50 kA
Frequency 50 / 60 Hz
Installation Withdrawable
Configuration Moving part
Main-circuit connection Separate chassis part
Auxiliary contacts 4 change-over contacts
Integrated earth-fault protection No
Degree of protection IP30
Power loss 176 W
Electrical durability 15,000 cycles
Mechanical durability 25,000 cycles
Standard IEC 60947-2
EAN 8015644767853

Frequently Asked Questions

What is the ABB 1SDA072935R1 used for?

The ABB 1SDA072935R1 is a 1250 A air circuit breaker used for switching, isolation and protection of low-voltage electrical distribution systems against overloads and short circuits.

What protection unit is fitted to the ABB 1SDA072935R1?

The breaker incorporates an Ekip Touch LSI electronic trip unit, providing configurable long-time, selective short-time and instantaneous protection.

What is the breaking capacity of the E2.2N 1250?

The E2.2N 1250 provides an ultimate short-circuit breaking capacity of 66 kA at 400/415 V AC, with the 66 kA rating maintained up to 690 V AC.

Does the ABB 1SDA072935R1 provide earth-fault protection?

No. This version uses the Ekip Touch LSI release, providing long-time, short-time and instantaneous protection; an LSIG version is available where integrated ground-fault protection is required.

Is the ABB 1SDA072935R1 a fixed or withdrawable breaker?

The 1SDA072935R1 is a withdrawable moving-part version of the SACE Emax 2 E2.2N, designed for connection to the corresponding separate chassis part and convenient withdrawal for inspection, servicing or replacement.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine dependable high-current circuit protection, advanced electronic trip technology and maintainable withdrawable construction for modern low-voltage power distribution systems.