1SDA072906R1 ABB E2.2N 1000 Ekip Touch LSIG 4P WMP Air Circuit Breaker

1SDA072906R1 ABB E2.2N 1000 Ekip Touch LSIG 4P WMP Air Circuit Breaker

ABB 1SDA072906R1 Emax 2 E2.2N 1000 Ekip Touch LSIG four-pole withdrawable air circuit breaker moving part rated at 1000 A with long-time, selective short-time, instantaneous and earth-fault protection.

SKU: 1SDA072906R1MPN: 1SDA072906R1
Price
List Price £8,478.01 ex VAT
Your Price (ex VAT) Save 25%
£6,358.51 25% OFF
You save £2,119.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,358.51
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,358.51

Why Choose the ABB E2.2N 1000 Ekip Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E2.2N 1000 Ekip Touch LSIG 4p WMP, order code 1SDA072906R1, is a high-performance four-pole air circuit breaker moving part from the ABB SACE Emax 2 range. Designed for demanding low-voltage power distribution, transformer and installation protection, it combines a 1000 A rated uninterrupted current with the advanced Ekip Touch LSIG electronic trip unit.

The Ekip Touch LSIG release provides comprehensive long-time (L), selective short-time (S), instantaneous (I) and earth-fault (G) protection. This combination allows the breaker to protect against overloads, short circuits and earth faults while supporting selective coordination with downstream protective devices, helping improve both equipment protection and continuity of supply.

The E2.2N frame provides an ultimate short-circuit breaking capacity of 66 kA across its specified AC operating-voltage range up to 690 V AC. Its withdrawable moving-part construction supports efficient switchboard maintenance, while the four-pole arrangement incorporates a neutral pole rated at 100% of the rated uninterrupted current.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1000 A rated uninterrupted current for high-current industrial and commercial systems.
  • Ekip Touch LSIG electronic trip unit provides comprehensive electronic protection.
  • Long-time, selective short-time, instantaneous and earth-fault protection in a single release.
  • 66 kA ultimate short-circuit breaking capacity across the specified AC voltage range up to 690 V.
  • 66 kA rated short-time withstand current for 1 s supports selective power-distribution designs.
  • Four-pole configuration with a 100% rated neutral pole.
  • Withdrawable moving-part design facilitates inspection, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E2.2N air circuit breaker moving part.
  • 1000 A rated current.
  • 4-pole configuration.
  • Ekip Touch LSIG electronic trip unit.
  • Long-time L overload protection.
  • Selective short-time S short-circuit protection.
  • Instantaneous I short-circuit protection.
  • Earth-fault G protection.
  • Touch interface for protection configuration and operating information.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at specified AC operating voltages from 400–690 V.
  • 100% Ics-to-Icu ratio for high service breaking performance.

Comprehensive LSIG Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution systems against potentially damaging electrical faults. The Ekip Touch LSIG release combines long-time overload, selective short-time, instantaneous and earth-fault protection, enabling the breaker to respond appropriately to a broad range of abnormal operating conditions.

The addition of earth-fault protection makes the LSIG configuration particularly suitable for installations requiring comprehensive system protection from a single electronic release. Combined with the E2.2N frame's 66 kA breaking capacity and withdrawable architecture, the 1SDA072906R1 provides dependable protection and convenient maintenance access for modern industrial and commercial switchboards.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Transformer and installation protection.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process plant switchgear.
  • Selective distribution networks requiring coordinated protection.
  • Systems requiring integrated earth-fault protection.
  • Four-wire low-voltage power distribution networks.

Technical Specifications

Series SACE Emax 2
Order code 1SDA072906R1
GTIN / EAN 8015644767563
Product type Air circuit breaker moving part
Frame / sub-type E2.2
Short-circuit performance level N
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Number of poles 4P
Neutral pole current 100% of Iu
Current type AC
Installation Withdrawable, moving part
Version W
Trip unit Ekip Touch LSIG
Release type Electronic (EL)
Protection functions L, S, I and G
Rated operational voltage 690 V AC
Rated voltage (Ur) 690 V
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate breaking capacity (Icu) at 400 V AC 66 kA
Ultimate breaking capacity (Icu) at 415 V AC 66 kA
Ultimate breaking capacity (Icu) at 440 V AC 66 kA
Ultimate breaking capacity (Icu) at 500 V AC 66 kA
Ultimate breaking capacity (Icu) at 525 V AC 66 kA
Ultimate breaking capacity (Icu) at 690 V AC 66 kA
Service breaking capacity (Ics) 66 kA at specified AC voltages up to 690 V
Service breaking capacity relative to Icu 100%
Short-time withstand current (Icw) 66 kA for 1 s; 50 kA for 3 s
Power loss 113 W
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072906R1?

The ABB 1SDA072906R1 is an Emax 2 E2.2N four-pole withdrawable air circuit breaker moving part rated at 1000 A and equipped with an Ekip Touch LSIG electronic trip unit.

What protection functions does the Ekip Touch LSIG trip unit provide?

The Ekip Touch LSIG provides long-time overload (L), selective short-time (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the rated current of the ABB E2.2N 1SDA072906R1?

The breaker has a rated current and rated uninterrupted current of 1000 A, with a four-pole configuration and a neutral pole rated at 100% of Iu.

What is the breaking capacity of the ABB E2.2N 1000?

The E2.2N has an ultimate short-circuit breaking capacity of 66 kA at its specified AC operating voltages up to 690 V AC, with service breaking capacity equal to 100% of Icu.

Does the ABB 1SDA072906R1 provide earth-fault protection?

Yes. The G function of the Ekip Touch LSIG electronic trip unit provides earth-fault protection in addition to long-time, selective short-time and instantaneous protection.

Trusted ABB Emax 2 Power Distribution Protection