ABB 1SDA072887R1 is an Emax 2 E2.2S 800 A four-pole withdrawable air circuit breaker moving part with an Ekip G Touch LSIG electronic trip unit for advanced low-voltage power distribution and generator protection.
£9,062.68
The ABB 1SDA072887R1 is a high-performance Emax 2 E2.2S 800 A four-pole air circuit breaker moving part designed for advanced protection and control in low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 air circuit breaker series, it combines robust withdrawable construction with the sophisticated Ekip G Touch LSIG electronic trip unit.
This E2.2S circuit breaker is engineered for demanding industrial, commercial and infrastructure power distribution applications. The Ekip G Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, while the Ekip G platform is particularly suited to applications requiring advanced generator and distribution protection functionality.
With a rated current of 800 A, a four-pole configuration and an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC, the 1SDA072887R1 provides dependable protection for demanding high-current distribution circuits. Its withdrawable moving-part design enables integration with the appropriate Emax 2 E2.2 fixed part and supports efficient inspection, servicing and replacement within switchgear assemblies.
Air circuit breakers such as the ABB Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage distribution circuits. The E2.2S performance level combines high short-circuit breaking capability with substantial short-time withstand performance, making it suitable for main switchboards, generator systems and industrial distribution networks where protection selectivity and continuity of supply are important.
The Ekip G Touch LSIG trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. Combined with the E2.2S frame's 85 kA breaking capacity at 400–440 V AC and withdrawable architecture, the 1SDA072887R1 provides a flexible protection solution for sophisticated low-voltage power distribution and generator applications.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2 |
| Performance level | S |
| ABB order code / MPN | 1SDA072887R1 |
| Product type | Air circuit breaker moving part |
| Rated current | 800 A |
| Rated uninterrupted current | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Rated impulse withstand voltage | 12 kV |
| Number of poles | 4 |
| Neutral pole current | 100% of rated current |
| Trip unit | Ekip G Touch LSIG |
| Trip unit type | Electronic release |
| Protection functions | LSIG – long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw, 1 s) | 66 kA |
| Rated short-time withstand current (Icw, 3 s) | 50 kA |
| Current type | AC |
| Execution | Withdrawable moving part (WMP) |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 72 W |
| Mechanical durability | 25,000 operating cycles |
| Electrical durability | 15,000 operating cycles |
| Dimensions (H × W × D) | 425 × 407 × 383 mm |
| Weight | 55 kg |
| Standard | IEC 60947-2 |
| EAN | 8015644767372 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA072887R1 is an Emax 2 air circuit breaker moving part designed for switching and protecting high-current low-voltage electrical distribution and generator circuits in industrial, commercial and infrastructure applications.
The E2.2S 800 has a rated current of 800 A and is supplied in a four-pole configuration with a neutral pole rated at 100% of the rated current.
The Ekip G Touch LSIG electronic trip unit provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and earth-fault protection (G).
The E2.2S 800 has an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, with a rated short-time withstand current of 66 kA for 1 s.
The 1SDA072887R1 is the withdrawable moving part (WMP) of an ABB Emax 2 circuit-breaker system and is designed for installation with the appropriate E2.2 fixed part.
ABB SACE Emax 2 air circuit breakers provide advanced protection and control for modern low-voltage power distribution and generation systems, combining high short-circuit performance, intelligent electronic protection and flexible withdrawable switchgear integration.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.