1SDA072852R1 ABB E1.2C 1600 Ekip Dip LSI 4p WMP Air Circuit Breaker 1600 A

1SDA072852R1 ABB E1.2C 1600 Ekip Dip LSI 4p WMP Air Circuit Breaker 1600 A

ABB 1SDA072852R1 E1.2C 1600 Ekip Dip LSI 4p WMP is a 1600 A four-pole withdrawable SACE Emax 2 air circuit breaker with Ekip Dip LSI electronic protection for low-voltage power distribution systems.

SKU: 1SDA072852R1MPN: 1SDA072852R1
Price
List Price £6,600.67 ex VAT
Your Price (ex VAT) Save 25%
£4,950.50 25% OFF
You save £1,650.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,950.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,950.50

Why Choose the ABB E1.2C 1600 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB E1.2C 1600 Ekip Dip LSI 4p WMP, order code 1SDA072852R1, is a high-performance four-pole air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for protection and switching in low-voltage power distribution systems. With a rated uninterrupted current of 1600 A, it combines the compact E1.2 frame with an Ekip Dip LSI electronic protection release.

The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. This combination enables effective protection and selective coordination within electrical distribution networks, helping isolate faults while maintaining continuity elsewhere in the installation.

The E1.2C performance level provides a rated ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC, while the breaker is suitable for systems with rated operational voltages up to 690 V AC. Its four-pole withdrawable moving-part construction supports efficient inspection and maintenance within compatible ABB SACE Emax 2 switchgear assemblies.

Key Advantages

  • High-performance 1600 A four-pole air circuit breaker for low-voltage power distribution.
  • Ekip Dip LSI electronic trip unit provides long-time, short-time and instantaneous overcurrent protection.
  • Short-time protection supports selective coordination within electrical distribution systems.
  • Rated ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC.
  • 690 V AC rated operational voltage for demanding industrial electrical systems.
  • Withdrawable moving-part construction supports efficient switchgear servicing and maintenance.

Key Features

  • ABB SACE Emax 2 E1.2 air circuit breaker platform.
  • 1600 A rated uninterrupted current.
  • Four-pole configuration.
  • Ekip Dip LSI electronic release.
  • Long-time overload, short-time and instantaneous short-circuit protection.
  • 50 kA Icu at 400/415 V AC.
  • 42 kA Icu at 690 V AC.
  • Rated operational voltage up to 690 V AC.
  • Withdrawable moving-part design for compatible Emax 2 switchgear assemblies.
  • Designed for high-current industrial and commercial power distribution.

Selective Circuit Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical installations against overloads and short circuits while providing controlled switching and isolation of high-current circuits. The compact E1.2 platform combines high breaking performance with electronic protection for switchboards, distribution panels and demanding industrial power systems.

The Ekip Dip LSI trip unit adds short-time protection to long-time overload and instantaneous short-circuit functions, allowing greater flexibility when coordinating upstream and downstream protective devices. Combined with the breaker’s 1600 A current rating and withdrawable construction, this makes the E1.2C suitable for installations requiring dependable high-current protection and effective selectivity.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Transformer and generator distribution applications.
  • Incoming and outgoing switchgear feeders.
  • High-current distribution systems requiring selective overcurrent protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA072852R1
Product type Air circuit breaker
Frame / sub-type E1.2
Short-circuit performance level C
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Release Ekip Dip LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous overcurrent protection (LSI)
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Version Withdrawable moving part
Current type AC
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072852R1 used for?

The ABB 1SDA072852R1 is a 1600 A four-pole air circuit breaker designed for switching and protection in low-voltage industrial, commercial and infrastructure power distribution systems.

What protection functions does the Ekip Dip LSI release provide?

The Ekip Dip LSI electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the E1.2C 1600?

The breaker has a rated ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC and 42 kA at 690 V AC.

What is the difference between Ekip Dip LI and Ekip Dip LSI?

The Ekip Dip LSI release adds adjustable short-time protection to the long-time and instantaneous protection functions, providing additional flexibility for selective coordination between protective devices.

Is the ABB 1SDA072852R1 a fixed or withdrawable circuit breaker?

The E1.2C 1600 Ekip Dip LSI 4p WMP is supplied as a withdrawable moving part for use within compatible ABB SACE Emax 2 switchgear assemblies.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers are designed for dependable protection, switching and control in low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection technology.