1SDA072850R1 ABB E1.2B 1600 Ekip G Hi-Touch LSIG 4P WMP Air Circuit Breaker

1SDA072850R1 ABB E1.2B 1600 Ekip G Hi-Touch LSIG 4P WMP Air Circuit Breaker

ABB 1SDA072850R1 SACE Emax 2 E1.2B 1600 A four-pole withdrawable air circuit breaker with Ekip G Hi-Touch LSIG electronic protection for advanced generator and low-voltage power-distribution applications.

SKU: 1SDA072850R1MPN: 1SDA072850R1
Price
List Price £10,894.14 ex VAT
Your Price (ex VAT) Save 25%
£8,170.61 25% OFF
You save £2,723.54 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,170.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,170.61

Why Choose the ABB E1.2B 1600 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072850R1 is a SACE Emax 2 E1.2B air circuit breaker designed for generator protection and demanding low-voltage power-distribution systems. Rated at 1600 A, this four-pole withdrawable breaker combines ABB's compact E1.2B frame with an advanced Ekip G Hi-Touch LSIG electronic trip unit, providing Long-time, Short-time, Instantaneous and Ground-fault protection.

The E1.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s. Designed for low-voltage systems up to 690 V AC, this configuration combines substantial current capacity with the selective protection and generator-oriented functionality required in industrial, infrastructure and critical-power installations.

This model is supplied as a four-pole withdrawable moving part (WMP) for use with the appropriate Emax 2 fixed part. ABB specifies an Ekip G Hi-Touch LSIG R 1600 solid-state AC release together with four auxiliary contacts and circuit-breaker open/closed indication. The Ekip G Hi-Touch platform extends LSIG protection with advanced generator-oriented protection, measurement, monitoring and power-management capabilities.

Key Advantages

  • High-current 1600 A air circuit breaker for generator and low-voltage distribution protection.
  • Four-pole configuration for switching and protection of four-conductor systems.
  • Ekip G Hi-Touch LSIG combines comprehensive electronic protection with generator-oriented functionality.
  • 42 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 42 kA short-time withstand current for 1 s supports selective protection coordination.
  • Integrated Ground-fault (G) protection provides protection against earth-fault conditions.
  • Advanced measurement, monitoring and power-management capabilities support sophisticated electrical networks.
  • Generator-oriented Ekip G functionality makes the breaker particularly suitable for generating-set applications.
  • Withdrawable construction supports efficient inspection, maintenance and replacement.
  • Four auxiliary contacts facilitate switchboard signalling and automation integration.

Key Features

  • ABB SACE Emax 2 E1.2B air circuit breaker.
  • 1600 A rated uninterrupted current.
  • 4-pole configuration.
  • Ekip G Hi-Touch LSIG R 1600 solid-state electronic AC release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • Generator-oriented protection and power-management functionality.
  • 690 V AC rated operational voltage.
  • 42 kA Icu at 440 V AC.
  • 42 kA Icw for 1 s.
  • Advanced measurement and monitoring functionality.
  • Four auxiliary contacts fitted.
  • Circuit-breaker open/closed position indication.
  • Withdrawable moving-part construction for maintainable switchboard installations.

Advanced Generator Protection and Power Management

The ABB SACE Emax 2 E1.2B combines high-current switching with the advanced capabilities of the Ekip G Hi-Touch LSIG release. Long-time, Short-time, Instantaneous and Ground-fault functions provide comprehensive electronic protection against overload, short-circuit and earth-fault conditions, while the Ekip G platform adds generator-oriented functions for generating sets and complex power-generation systems.

With a 1600 A current rating, 42 kA ultimate short-circuit breaking capacity at 440 V AC and 42 kA short-time withstand capability for 1 s, the E1.2B is suited to installations requiring dependable fault performance and selective coordination. Its withdrawable construction allows the moving breaker portion to be separated from the appropriate fixed chassis, supporting efficient maintenance and replacement where continuity of electrical service is important.

Typical Applications

  • Generator and generating-set protection.
  • Standby and emergency power-generation systems.
  • Main and distribution switchboards.
  • Industrial low-voltage power distribution systems.
  • Data centres and critical-power installations.
  • Hospitals and essential-services power systems.
  • Manufacturing and process-control facilities.
  • Infrastructure and utility distribution systems.
  • Generator-to-network and multi-source distribution architectures.
  • Four-pole circuits requiring advanced LSIG protection, monitoring and power management.

Technical Specifications

Series SACE Emax 2
Frame / subtype E1.2B
ABB order code 1SDA072850R1
EAN / GTIN 8015644767006
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Performance level B
Rated current 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4P
Current type AC
Rated operational voltage Up to 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Rated short-time withstand current (Icw) 42 kA for 1 s
Trip unit Ekip G Hi-Touch LSIG
Release designation Ekip G Hi-Touch LSIG R 1600
Release type Solid-state electronic AC release
Protection functions Long-time (L), Short-time (S), Instantaneous (I), Ground-fault (G)
Integrated ground-fault protection Yes
Generator-oriented functionality Ekip G Hi-Touch
Version Withdrawable moving part (WMP)
Main-circuit connection Through separate fixed chassis
Auxiliary contacts 4
Breaker position indication Open / closed
Electrical durability at up to 440 V 3000 cycles
Electrical durability at 500–690 V 6500 cycles
Mechanical durability 20000 cycles
Product net width 348 mm
Product net height 363.5 mm
Product net depth 271 mm
Product net weight 14 kg
Standard / approval IEC
Country of origin Italy

Frequently Asked Questions

What is the ABB 1SDA072850R1 used for?

The ABB 1SDA072850R1 is a 1600 A four-pole withdrawable air circuit breaker designed for generator protection and demanding low-voltage power-distribution systems requiring advanced electronic protection and power-management functionality.

What protection release is fitted to the ABB 1SDA072850R1?

The breaker is fitted with an Ekip G Hi-Touch LSIG R 1600 solid-state electronic release, combining Long-time, Short-time, Instantaneous and Ground-fault protection with advanced generator-oriented measurement, monitoring and power-management capabilities.

What does LSIG mean on the Ekip G Hi-Touch trip unit?

LSIG denotes Long-time, Short-time, Instantaneous and Ground-fault protection. Together these functions provide protection against sustained overloads, short-circuit faults and earth-fault conditions.

What is the breaking capacity of the ABB E1.2B 1600?

The E1.2B 1600 has a rated ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s.

Is the ABB 1SDA072850R1 a fixed or withdrawable circuit breaker?

The 1SDA072850R1 is a withdrawable moving-part (WMP) circuit breaker designed for use with the appropriate separate fixed chassis in an ABB SACE Emax 2 switchboard installation.

Trusted Protection for Generator and Distribution Systems

ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced generator-oriented electronic protection and flexible withdrawable construction to provide dependable fault protection, selective coordination and power management for critical low-voltage electrical systems.