1SDA072847R1 ABB E1.2B 1600 Ekip G Touch LSIG 4p WMP Air Circuit Breaker

1SDA072847R1 ABB E1.2B 1600 Ekip G Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA072847R1 is an Emax 2 E1.2B 1600 A four-pole withdrawable air circuit breaker moving part with an Ekip G Touch LSIG electronic trip unit for advanced generator, overload, short-circuit and earth-fault protection.

SKU: 1SDA072847R1MPN: 1SDA072847R1
Price
List Price £10,091.62 ex VAT
Your Price (ex VAT) Save 25%
£7,568.72 25% OFF
You save £2,522.91 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,568.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,568.72

Why Choose the ABB E1.2B 1600 Ekip G Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E1.2B 1600 Ekip G Touch LSIG 4p WMP, order code 1SDA072847R1, is a high-performance four-pole withdrawable air circuit breaker moving part designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 E1.2 series, it combines a 1600 A rated current with an Ekip G Touch LSIG solid-state electronic trip unit for advanced overload, selective short-circuit, instantaneous and earth-fault protection.

The Ekip G Touch LSIG trip unit is designed for applications where generator and distribution protection require advanced electronic control. It provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, with configurable settings that support selective coordination and dependable protection across generator-fed and conventional low-voltage networks.

The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC and 42 kA at 690 V AC, together with a rated short-time withstand current of 42 kA for 1 s. Its withdrawable four-pole construction supports maintainable switchboard designs where rapid inspection, servicing and replacement of the breaker moving part are important.

Key Advantages

  • 1600 A rated current for high-current low-voltage distribution and generator applications.
  • Four-pole configuration for comprehensive switching and circuit protection.
  • Ekip G Touch LSIG electronic trip unit optimised for generator and distribution protection.
  • Long-time, short-time, instantaneous and earth-fault protection.
  • 42 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • 42 kA rated short-time withstand current for 1 s.
  • Withdrawable moving-part design supports efficient inspection, servicing and replacement.
  • Part of the modular ABB SACE Emax 2 air circuit breaker platform.

Key Features

  • ABB SACE Emax 2 E1.2B air circuit breaker moving part.
  • 1600 A rated uninterrupted current.
  • 4-pole construction.
  • Ekip G Touch LSIG solid-state electronic protection release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Generator-oriented protection and control functionality.
  • 690 V AC rated operational voltage.
  • 42 kA Icu across key low-voltage operating voltages up to 690 V AC.
  • Withdrawable execution for use with the corresponding Emax 2 fixed part.
  • Fitted with four auxiliary contacts.
  • Circuit breaker open/closed position indication.

Advanced Generator and Distribution Protection

The ABB Ekip G Touch platform extends Emax 2 electronic protection capabilities for generator applications and complex distribution systems. Its LSIG protection functions provide coordinated response to sustained overloads, selective short circuits, high-magnitude instantaneous faults and earth faults, helping protect generators, conductors, switchgear and connected loads under demanding operating conditions.

The withdrawable E1.2B construction is particularly suitable for generator switchboards, industrial distribution panels and other installations where serviceability and continuity are important. The moving breaker can be withdrawn from its corresponding fixed part for inspection or maintenance, while the electronic trip unit provides flexible protection configuration for the requirements of the electrical network.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure power distribution.
  • Manufacturing and process facilities.
  • Emergency and standby generation systems.
  • Critical power distribution installations.
  • Withdrawable switchgear requiring advanced LSIG protection.

Technical Specifications

Series SACE Emax 2 E1.2
Order code 1SDA072847R1
Product type Air circuit breaker moving part
Rated uninterrupted current 1600 A
Rated operational voltage 690 V AC
Number of poles 4
Performance level B
Trip unit Ekip G Touch LSIG
Release type Electronic
Protection functions L, S, I, G
Ultimate short-circuit breaking capacity at 400 V AC 42 kA
Ultimate short-circuit breaking capacity at 415 V AC 42 kA
Ultimate short-circuit breaking capacity at 440 V AC 42 kA
Ultimate short-circuit breaking capacity at 500 V AC 42 kA
Ultimate short-circuit breaking capacity at 525 V AC 42 kA
Ultimate short-circuit breaking capacity at 690 V AC 42 kA
Service short-circuit breaking capacity 42 kA
Rated short-time withstand current (1 s) 42 kA
Rated short-time withstand current (3 s) 24 kA
Construction Withdrawable
Auxiliary contacts 4
Position indication Circuit breaker open/closed
Standard IEC
Product net weight 20 kg
EAN 8015644766979

Frequently Asked Questions

What is the ABB 1SDA072847R1?

The ABB 1SDA072847R1 is an Emax 2 E1.2B four-pole withdrawable air circuit breaker moving part rated at 1600 A and equipped with an Ekip G Touch LSIG electronic trip unit.

What protection functions does the Ekip G Touch LSIG provide?

The Ekip G Touch LSIG provides long-time (L), short-time (S), instantaneous (I) and earth-fault (G) protection, with advanced functionality suited to generator and distribution applications.

What is the breaking capacity of the E1.2B 1600?

The E1.2B 1600 provides an ultimate short-circuit breaking capacity of 42 kA at 400/415 V AC and 42 kA at 690 V AC.

Is the ABB 1SDA072847R1 fixed or withdrawable?

This model is a withdrawable moving part designed for installation with the corresponding ABB SACE Emax 2 fixed part.

What is the rated current of the ABB 1SDA072847R1?

The ABB 1SDA072847R1 has a rated uninterrupted current of 1600 A and is designed for demanding generator and low-voltage distribution applications.

Trusted Power Protection from ABB

ABB SACE Emax 2 air circuit breakers combine advanced generator-oriented electronic protection, dependable short-circuit performance and service-friendly withdrawable construction for demanding low-voltage power systems.