ABB 1SDA072843R1 SACE Emax 2 E1.2B 1600 four-pole withdrawable air circuit breaker moving part with Ekip Dip LSIG electronic protection, 1600 A rated current and 42 kA breaking capacity up to 690 V AC.
£5,236.41
The ABB 1SDA072843R1 is a high-performance SACE Emax 2 E1.2B air circuit breaker designed for reliable protection and control of low-voltage electrical distribution systems. Configured as an E1.2B 1600 Ekip Dip LSIG 4p WMP, this four-pole withdrawable moving part combines a 1600 A rated uninterrupted current with ABB's Ekip Dip LSIG solid-state electronic protection release.
As part of the ABB SACE Emax 2 air circuit breaker series, the E1.2B is engineered for industrial, commercial and infrastructure power distribution applications. The Ekip Dip LSIG trip unit provides adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, with the principal protection settings configured through straightforward DIP switches.
The E1.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA from 380–690 V AC. Its 1600 A rating, four-pole configuration and withdrawable construction make the 1SDA072843R1 well suited to substantial switchboard applications where dependable fault interruption, earth-fault protection, isolation and convenient maintenance are required.
Air circuit breakers such as the ABB SACE Emax 2 E1.2B protect low-voltage electrical distribution systems against potentially damaging overload, short-circuit and earth-fault conditions while providing dependable switching and isolation. With a 1600 A rated current and 42 kA breaking capacity up to 690 V AC, this E1.2B configuration provides robust protection for substantial switchboards, feeders and connected electrical equipment.
The Ekip Dip LSIG electronic trip unit combines four principal protection functions in one configurable release. Long-time protection addresses sustained overloads, short-time protection supports selective coordination, instantaneous protection responds rapidly to severe short circuits, and earth-fault protection provides an additional layer of protection against ground faults. DIP-switch adjustment and the Emax 2 withdrawable architecture provide a practical combination of configurable protection and maintainability.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| Order code / MPN | 1SDA072843R1 |
| EAN | 8015644766931 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Construction | Withdrawable moving part |
| Number of poles | 4 |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Protection release | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Overload protection setting | 0.4–1 × In |
| Overload release current setting | 640–1600 A |
| Short-time selective protection setting | 0.6–10 × In |
| Short-time delayed short-circuit setting | 960–16000 A |
| Instantaneous protection setting | 1.5–15 × In |
| Instantaneous short-circuit setting | 2400–24000 A |
| Earth-fault protection setting | 0.1–1 × In |
| Earth-fault protection | Integrated |
| Protection adjustment | DIP switches |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Approximate dimensions | 330 × 348 × 271 mm |
| Standard | IEC 60947-2 |
| Product family | Emax 2 Air Circuit Breakers |
The ABB 1SDA072843R1 is an Emax 2 air circuit breaker moving part designed to protect and control low-voltage electrical distribution systems against overloads, short circuits and earth faults.
The breaker has a rated uninterrupted current of 1600 A, making it suitable for substantial industrial, commercial and infrastructure power distribution loads.
The E1.2B 1600 provides a rated ultimate short-circuit breaking capacity of 42 kA at 380–690 V AC, providing consistent fault interruption performance across its principal low-voltage operating range.
This model is fitted with the ABB Ekip Dip LSIG electronic release, providing adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection with DIP-switch configuration.
The 1SDA072843R1 is a four-pole withdrawable moving part for the Emax 2 E1.2B circuit breaker system and is designed for use with the corresponding fixed part in a low-voltage switchboard.
ABB SACE Emax 2 air circuit breakers combine dependable high-current fault interruption with configurable electronic protection, integrated earth-fault protection and maintainable withdrawable construction for demanding industrial, commercial and infrastructure low-voltage distribution systems.