ABB 1SDA072823R1 SACE Emax 2 E1.2N 1250 A four-pole withdrawable air circuit breaker mobile part with Ekip Dip LSIG electronic protection, 690 V AC rated operational voltage, 66 kA short-circuit breaking capacity at 400–440 V AC and integrated earth-fault protection.

SKU: 1SDA072823R1MPN: 1SDA072823R1
Price
List Price £8,426.41 ex VAT
Your Price (ex VAT) Save 25%
£6,319.81 25% OFF
You save £2,106.60 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,319.81
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,319.81

Why Choose the ABB E1.2N 1250 Ekip Dip LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072823R1 is a SACE Emax 2 E1.2N air circuit breaker (ACB) designed for dependable protection and switching in low-voltage electrical distribution systems. Rated at 1250 A, this four-pole breaker combines ABB’s compact E1.2N frame with an Ekip Dip LSIG electronic trip unit providing long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.

The Ekip Dip LSIG release provides adjustable electronic protection using straightforward DIP-switch settings. Its LSIG functionality gives comprehensive protection against overloads, selective short circuits, instantaneous short circuits and earth faults, making the breaker suitable for distribution systems where coordinated protection and earth-fault detection are required.

The 1SDA072823R1 is a four-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 1250 A and rated operational voltage of 690 V AC. The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC, reducing to 50 kA at 500–690 V AC, together with a rated short-time withstand current of 50 kA for 1 second.

Key Advantages

  • 1250 A rated uninterrupted current for substantial low-voltage distribution loads.
  • 690 V AC rated operational voltage supports a broad range of LV distribution applications.
  • 66 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 50 kA ultimate breaking capacity at 500–690 V AC.
  • 50 kA short-time withstand current for 1 second supports selective protection strategies.
  • Ekip Dip LSIG electronic trip unit provides adjustable overload and short-circuit protection.
  • Integrated earth-fault protection provides additional protection against faults to earth.
  • Four-pole configuration with 100% neutral-pole current capability suits three-phase four-wire distribution networks.
  • Withdrawable mobile-part construction facilitates isolation, inspection, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 1250 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four-pole configuration.
  • 100% neutral-pole current rating.
  • N short-circuit performance level.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • 50 kA Icw for 1 second.
  • 30 kA Icw for 3 seconds.
  • Ekip Dip LSIG electronic trip unit.
  • LSIG protection provides long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.
  • 500–1250 A long-time overload adjustment range.
  • 750–12500 A short-time protection adjustment range.
  • 1875–18750 A instantaneous protection adjustment range.
  • 125–1250 A earth-fault protection adjustment range.
  • Protection settings configured through DIP switches.
  • Withdrawable mobile part (WMP) configuration.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.

Comprehensive LSIG Distribution Protection

The ABB SACE Emax 2 E1.2N combines compact construction with robust fault-current performance for low-voltage networks requiring coordinated circuit protection. With a rated uninterrupted current of 1250 A, an ultimate breaking capacity of 66 kA at 400–440 V AC and a short-time withstand capability of 50 kA for 1 second, this configuration provides dependable protection for demanding commercial and industrial distribution systems.

The Ekip Dip LSIG electronic trip unit provides adjustable long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection. The short-time function supports selective coordination between protective devices, while the integrated earth-fault function provides an additional layer of protection against faults to earth. DIP-switch adjustment provides a straightforward method of configuring the principal protection thresholds.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Three-phase four-wire electrical distribution systems.
  • Commercial building power distribution.
  • Industrial main incomers and feeder protection.
  • Transformer secondary distribution systems.
  • Infrastructure and utility installations.
  • Manufacturing and process facilities.
  • Critical-power distribution systems.
  • Systems requiring selective short-circuit and earth-fault protection.
  • Switchboards requiring withdrawable four-pole circuit breaker construction.

Technical Specifications

Series SACE Emax 2
Frame E1.2
Order code / SKU 1SDA072823R1
EAN 8015644766733
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Number of poles 4
Neutral-pole current 100% of Iu
Current type AC
Performance level N
Trip unit Ekip Dip
Release type Electronic
Protection functions LSIG
Long-time overload adjustment 0.4–1 × In (500–1250 A)
Short-time delayed protection adjustment 0.6–10 × In (750–12500 A)
Instantaneous protection adjustment 1.5–15 × In (1875–18750 A)
Earth-fault protection adjustment 0.1–1 × In (125–1250 A)
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection Yes
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) 50 kA
Rated short-time withstand current (Icw, 1 s) 50 kA
Rated short-time withstand current (Icw, 3 s) 30 kA
Execution Withdrawable mobile part
Main circuit connection Connection through corresponding fixed part
Auxiliary contacts 4
Open / closed position indication Yes
Electrical durability at ≤440 V AC 8000 cycles
Electrical durability at 500–690 V AC 6500 cycles
Mechanical durability 20000 cycles
Dimensions (W × H × D) 348 × 363.5 × 271 mm
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072823R1?

The ABB 1SDA072823R1 is a four-pole SACE Emax 2 E1.2N withdrawable air circuit breaker mobile part rated at 1250 A and equipped with an Ekip Dip LSIG electronic trip unit.

What are the current and voltage ratings of the ABB E1.2N 1SDA072823R1?

The breaker has a rated uninterrupted current of 1250 A and a rated operational voltage of 690 V AC, with a rated insulation voltage of 1000 V AC.

What is the breaking capacity of the ABB E1.2N 1250?

The E1.2N 1250 provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated short-time withstand current is 50 kA for 1 second and 30 kA for 3 seconds.

What does Ekip Dip LSIG mean?

Ekip Dip is ABB’s electronic trip unit with protection settings configured through DIP switches, while LSIG denotes long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.

Is the ABB 1SDA072823R1 fixed or withdrawable?

The 1SDA072823R1 is a four-pole withdrawable mobile part designed for use with the corresponding Emax 2 E1.2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.

Trusted for Comprehensive Low-Voltage Power Protection

ABB SACE Emax 2 air circuit breakers combine robust short-circuit performance, configurable electronic protection and flexible withdrawable construction for commercial, industrial and infrastructure low-voltage distribution systems requiring dependable selectivity and integrated earth-fault protection.