ABB 1SDA072822R1 SACE Emax 2 E1.2N 1250 four-pole withdrawable air circuit breaker moving part with Ekip Dip LSI electronic protection, 1250 A rated current and 66 kA breaking capacity at 380–440 V AC.
£5,823.24
The ABB 1SDA072822R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for reliable protection and control of demanding low-voltage electrical distribution systems. Configured as an E1.2N 1250 Ekip Dip LSI 4p WMP, this four-pole withdrawable moving part combines a 1250 A rated uninterrupted current with ABB's Ekip Dip LSI solid-state electronic protection release.
As part of the ABB SACE Emax 2 air circuit breaker series, the E1.2N is engineered for industrial, commercial and infrastructure power distribution applications requiring substantial fault interruption capability. The Ekip Dip LSI trip unit provides adjustable long-time overload, short-time selective short-circuit and instantaneous short-circuit protection, with the principal protection settings configured through straightforward DIP switches.
The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC, together with a rated short-time withstand current of 50 kA for 1 s. Its 1250 A rating, four-pole arrangement and withdrawable construction make the 1SDA072822R1 well suited to substantial switchboard applications where dependable fault interruption, selectivity and maintainability are required.
Air circuit breakers such as the ABB SACE Emax 2 E1.2N protect low-voltage electrical distribution systems against potentially damaging overload and short-circuit conditions while providing dependable switching and isolation. With a 66 kA breaking capacity at 380–440 V AC and 50 kA short-time withstand current for 1 s, this E1.2N configuration provides robust fault performance for substantial switchboards, feeders and connected electrical equipment.
The Ekip Dip LSI electronic trip unit adds adjustable short-time protection between the long-time overload and instantaneous protection stages. This supports effective coordination and selectivity between protective devices, while the DIP-switch interface and Emax 2 withdrawable architecture provide a practical combination of straightforward configuration, dependable circuit protection and convenient maintenance.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2N |
| Order code / MPN | 1SDA072822R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Construction | Withdrawable moving part |
| Number of poles | 4 |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 50 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 50 kA for 1 s / 30 kA for 3 s |
| Protection release | Ekip Dip LSI |
| Release type | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Overload protection setting | 0.4–1 × In |
| Overload release current setting | 500–1250 A |
| Short-time selective protection setting | 0.6–10 × In |
| Short-time delayed short-circuit setting | 750–12500 A |
| Instantaneous protection setting | 1.5–15 × In |
| Instantaneous short-circuit setting | 1875–18750 A |
| Protection adjustment | DIP switches |
| Integrated earth-fault protection | No |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open / closed |
| Integrated undervoltage release | No |
| Integrated motor drive | No |
| Optional motor drive | Yes |
| Standard | IEC 60947-2 |
| Product family | Emax 2 Air Circuit Breakers |
The ABB 1SDA072822R1 is an Emax 2 air circuit breaker moving part designed to protect and control demanding low-voltage electrical distribution systems against overloads and short circuits.
The breaker has a rated uninterrupted current of 1250 A, making it suitable for substantial industrial, commercial and infrastructure power distribution loads.
The E1.2N 1250 provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC, together with a rated short-time withstand current of 50 kA for 1 s.
This model is fitted with the ABB Ekip Dip LSI electronic release, providing adjustable long-time overload, short-time selective short-circuit and instantaneous short-circuit protection with DIP-switch configuration.
The 1SDA072822R1 is a four-pole withdrawable moving part for the Emax 2 E1.2N circuit breaker system and is designed for connection to the corresponding fixed part in a low-voltage switchboard.
ABB SACE Emax 2 air circuit breakers combine high fault interruption performance with configurable electronic protection and maintainable withdrawable construction for demanding industrial, commercial and infrastructure low-voltage distribution systems.