1SDA072810R1 ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

1SDA072810R1 ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA072810R1 SACE Emax 2 E1.2B 1250 A four-pole withdrawable air circuit breaker mobile part with Ekip G Hi-Touch LSIG electronic protection, 690 V AC rated operational voltage, 42 kA short-circuit breaking capacity and integrated earth-fault protection.

SKU: 1SDA072810R1MPN: 1SDA072810R1
Price
List Price £9,810.71 ex VAT
Your Price (ex VAT) Save 25%
£7,358.03 25% OFF
You save £2,452.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,358.03
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,358.03

Why Choose the ABB E1.2B 1250 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072810R1 is a SACE Emax 2 E1.2B air circuit breaker (ACB) designed for advanced generator and low-voltage power distribution protection. Rated at 1250 A, this four-pole breaker combines ABB’s compact E1.2B frame with an Ekip G Hi-Touch LSIG electronic trip unit, providing long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.

The Ekip G Hi-Touch release extends ABB’s advanced Hi-Touch protection and monitoring platform with functions suited to generator applications. It combines comprehensive LSIG circuit protection with advanced measurement, monitoring and power-management capabilities, making this configuration particularly suitable for generator incomers, standby generation systems and installations where generator and distribution protection must be coordinated.

The 1SDA072810R1 is a four-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 1250 A and rated operational voltage of 690 V AC. The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 400–690 V AC and a rated short-time withstand current of 42 kA for 1 second, supporting dependable protection across demanding low-voltage applications.

Key Advantages

  • 1250 A rated uninterrupted current for substantial generator and distribution loads.
  • 690 V AC rated operational voltage supports a broad range of low-voltage systems.
  • 42 kA ultimate short-circuit breaking capacity at 400–690 V AC for consistent fault interruption performance.
  • 42 kA short-time withstand current for 1 second supports selective protection strategies.
  • Ekip G Hi-Touch LSIG electronic trip unit combines advanced circuit and generator-oriented protection.
  • Long-time, short-time, instantaneous and earth-fault protection provides comprehensive fault protection.
  • Integrated earth-fault protection enhances protection of generators, feeders and distribution circuits.
  • Four-pole configuration with 100% neutral-pole current capability suits three-phase four-wire networks.
  • Withdrawable mobile-part construction facilitates isolation, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 1250 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Four-pole configuration.
  • 100% neutral-pole current rating.
  • B short-circuit performance level.
  • 42 kA Icu at 400–690 V AC.
  • 42 kA Icw for 1 second.
  • 24 kA Icw for 3 seconds.
  • 100% Ics/Icu service breaking capacity ratio.
  • Ekip G Hi-Touch LSIG electronic trip unit.
  • LSIG protection provides long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection.
  • Generator-oriented protection and advanced monitoring capabilities through the Ekip G Hi-Touch platform.
  • Withdrawable mobile part (WMP) configuration.
  • Four auxiliary contacts for status and control functions.
  • Circuit-breaker open/closed position indication.

Advanced Generator and Hi-Touch LSIG Protection

The ABB SACE Emax 2 E1.2B combines compact air circuit breaker construction with advanced electronic protection for generator and low-voltage distribution applications. With a rated uninterrupted current of 1250 A, an ultimate breaking capacity of 42 kA across 400–690 V AC and a short-time withstand capability of 42 kA for 1 second, this configuration provides robust and consistent fault-current performance within ABB’s compact E1.2 frame.

The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection while adding advanced functionality for generator applications. Combined with the monitoring and power-management capabilities of the Hi-Touch platform, it is well suited to installations where generator operation, electrical protection and system supervision must work together within a coordinated low-voltage network.

Typical Applications

  • Generator protection and generator incomer switchboards.
  • Standby and emergency generating systems.
  • Low-voltage main and sub-distribution switchboards.
  • Three-phase four-wire electrical distribution systems.
  • Industrial power generation and distribution systems.
  • Commercial and infrastructure backup-power installations.
  • Critical-power and continuity-of-supply applications.
  • Distributed generation and local energy systems.
  • Systems requiring selective short-circuit and earth-fault protection.
  • Advanced power monitoring and energy-management installations.
  • Switchboards requiring withdrawable four-pole circuit breaker construction.

Technical Specifications

Series SACE Emax 2
Frame E1.2
Order code / SKU 1SDA072810R1
EAN 8015644766603
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 4
Neutral-pole current 100% of Iu
Current type AC
Performance level B
Trip unit Ekip G Hi-Touch
Release type Electronic
Protection functions LSIG
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection Yes
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 42 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 42 kA
Rated short-time withstand current (Icw, 3 s) 24 kA
Execution Withdrawable mobile part
Main circuit connection Connection through corresponding fixed part
Auxiliary contacts 4
Open / closed position indication Yes
Power loss 244 W
Electrical durability at ≤440 V AC 8000 cycles
Electrical durability at 500–690 V AC 6500 cycles
Mechanical durability 20000 cycles
Dimensions (W × H × D) 348 × 363.5 × 271 mm
Net weight 20 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072810R1?

The ABB 1SDA072810R1 is a four-pole SACE Emax 2 E1.2B withdrawable air circuit breaker mobile part rated at 1250 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator and distribution protection.

What are the current and voltage ratings of the ABB E1.2B 1SDA072810R1?

The breaker has a rated uninterrupted current of 1250 A and a rated operational voltage of 690 V AC, with a rated insulation voltage of 1000 V AC.

What is the breaking capacity of the ABB E1.2B 1250?

The E1.2B 1250 provides an ultimate short-circuit breaking capacity of 42 kA at 400–690 V AC. Its rated short-time withstand current is 42 kA for 1 second and 24 kA for 3 seconds.

What does Ekip G Hi-Touch LSIG provide?

Ekip G Hi-Touch is ABB’s advanced electronic trip unit with generator-oriented protection, measurement, monitoring and power-management capabilities. LSIG provides long-time, short-time, instantaneous and earth-fault protection, giving this configuration comprehensive circuit protection including integrated earth-fault functionality.

Is the ABB 1SDA072810R1 fixed or withdrawable?

The 1SDA072810R1 is a four-pole withdrawable mobile part designed for use with the corresponding Emax 2 E1.2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.

Trusted for Advanced Generator and Power Distribution Protection

ABB SACE Emax 2 air circuit breakers combine dependable short-circuit performance, advanced generator-oriented electronic protection and flexible withdrawable construction for generating systems, industrial facilities, critical infrastructure and low-voltage distribution networks requiring comprehensive LSIG protection and advanced system supervision.