1SDA072784R1 ABB E1.2N 1000 Ekip Touch LI 4P WMP Air Circuit Breaker

1SDA072784R1 ABB E1.2N 1000 Ekip Touch LI 4P WMP Air Circuit Breaker

ABB 1SDA072784R1 SACE Emax 2 E1.2N 1000 A four-pole withdrawable air circuit breaker with Ekip Touch LI electronic overload and instantaneous short-circuit protection.

SKU: 1SDA072784R1MPN: 1SDA072784R1
Price
List Price £7,162.43 ex VAT
Your Price (ex VAT) Save 25%
£5,371.82 25% OFF
You save £1,790.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,371.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,371.82

Why Choose the ABB E1.2N 1000 Ekip Touch LI 4p WMP Air Circuit Breaker?

The ABB 1SDA072784R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for protection and switching in demanding low-voltage electrical distribution systems. Rated at 1000 A, this four-pole withdrawable moving part combines ABB's compact E1.2N frame with an Ekip Touch LI electronic trip unit, providing adjustable Long-time overload and Instantaneous short-circuit protection.

The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and 50/60 Hz operating frequency, it is engineered for robust protection in industrial, commercial and infrastructure power-distribution systems.

This model is supplied as a four-pole withdrawable moving part (WMP) for use with the appropriate separate Emax 2 fixed part. The Ekip Touch LI release features a touchscreen interface for intuitive protection configuration, with overload adjustment from 0.4–1 × In and instantaneous protection adjustment from 1.5–15 × In. Four auxiliary contacts and breaker open/closed position indication are fitted for integration into switchboard signalling and control systems.

Key Advantages

  • High-performance 1000 A air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole configuration for switching and protection of four-conductor circuits.
  • Ekip Touch LI electronic trip unit provides adjustable overload and instantaneous short-circuit protection.
  • 66 kA ultimate breaking capacity at 380–440 V AC supports installations with substantial prospective fault currents.
  • 50 kA ultimate breaking capacity at 500–690 V AC maintains strong protection at higher system voltages.
  • Large touchscreen interface supports intuitive protection setting and operation.
  • Adjustable Long-time and Instantaneous thresholds enable protection to be coordinated with the application.
  • Withdrawable construction supports efficient inspection, servicing and breaker replacement.
  • Four auxiliary contacts and open/closed indication facilitate switchboard monitoring and control.

Key Features

  • ABB SACE Emax 2 E1.2N air circuit breaker.
  • 1000 A rated current.
  • 4-pole configuration.
  • Ekip Touch LI solid-state electronic protection release.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • Long-time protection adjustable from 0.4–1 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 50/60 Hz rated frequency.
  • 66 kA Icu at 380–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • Touchscreen interface for protection configuration.
  • Four auxiliary contacts fitted.
  • Breaker open/closed position indication.
  • Withdrawable moving-part configuration for maintainable switchboard installations.

Touchscreen Electronic Protection for Power Distribution

The ABB SACE Emax 2 E1.2N provides a robust switching and protection point within low-voltage power-distribution systems. Its Ekip Touch LI release combines Long-time overload protection with Instantaneous short-circuit protection, helping protect conductors and connected equipment against sustained overcurrents and severe short-circuit faults. The touchscreen interface provides an intuitive method of configuring and reviewing the electronic protection settings.

With a 1000 A current rating, up to 66 kA ultimate short-circuit breaking capacity and 50 kA short-time withstand capability for 1 s, the E1.2N is suited to demanding distribution systems requiring strong fault performance. Its withdrawable construction allows the moving breaker portion to be separated from the appropriate fixed part, supporting efficient maintenance and replacement in installations where serviceability is important.

Typical Applications

  • Main and distribution switchboards.
  • Industrial low-voltage power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process-control facilities.
  • Data centres and critical-power installations.
  • Infrastructure and utility distribution systems.
  • Transformer secondary distribution.
  • Four-pole circuits requiring adjustable electronic overload and instantaneous short-circuit protection.

Technical Specifications

Series SACE Emax 2
Frame / subtype E1.2N
ABB order code 1SDA072784R1
EAN / GTIN 8015644766344
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Short-circuit performance level N
Rated current (In) 1000 A
Number of poles 4P
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated frequency 50/60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated short-time withstand current (Icw) at 415 V AC 50 kA for 1 s
Trip unit Ekip Touch LI
Release type Solid-state electronic
Protection functions Long-time (L), Instantaneous (I)
Long-time protection adjustment 0.4–1 × In
Long-time current setting range 400–1000 A
Instantaneous protection adjustment 1.5–15 × In
Instantaneous current setting range 1500–15000 A
Short-time delayed protection No
Integrated ground-fault protection No
Configuration interface Touchscreen display
Version Withdrawable moving part (WMP)
Auxiliary contacts 4
Breaker position indication Open / closed
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072784R1 used for?

The ABB 1SDA072784R1 is a 1000 A four-pole air circuit breaker designed for switching and protecting demanding low-voltage electrical power-distribution systems.

What protection release is fitted to the ABB 1SDA072784R1?

This breaker is fitted with an Ekip Touch LI solid-state electronic trip unit, providing adjustable Long-time overload and Instantaneous short-circuit protection through a touchscreen interface.

What does LI mean on the Ekip Touch trip unit?

LI denotes Long-time and Instantaneous protection. Long-time protection responds to sustained overload conditions, while Instantaneous protection provides rapid operation during high-level short-circuit faults.

What is the breaking capacity of the ABB E1.2N 1000?

The E1.2N 1000 has a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC.

Is the ABB 1SDA072784R1 a fixed or withdrawable circuit breaker?

The 1SDA072784R1 is a withdrawable moving-part (WMP) circuit breaker designed for use with the appropriate separate fixed part in an ABB SACE Emax 2 switchboard installation.

Trusted Protection for Low-Voltage Distribution

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced touchscreen electronic protection and flexible withdrawable construction to provide dependable switching and fault protection for demanding industrial, commercial and infrastructure power-distribution systems.