ABB 1SDA072750R1 SACE Emax 2 E1.2N 800 A four-pole withdrawable air circuit breaker with Ekip G Hi-Touch LSIG electronic protection for advanced generator and low-voltage power-distribution applications.

SKU: 1SDA072750R1MPN: 1SDA072750R1
Price
List Price £12,097.90 ex VAT
Your Price (ex VAT) Save 25%
£9,073.43 25% OFF
You save £3,024.48 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,073.43
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,073.43

Why Choose the ABB E1.2N 800 Ekip G Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072750R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for advanced protection, switching and power management in low-voltage electrical distribution and generator applications. Rated at 800 A, this four-pole withdrawable breaker combines ABB's compact E1.2N frame with the sophisticated Ekip G Hi-Touch LSIG electronic trip unit, providing comprehensive protection against overload, short-circuit and earth-fault conditions.

The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated operational voltage of 690 V AC, 1000 V AC insulation voltage and 12 kV impulse withstand voltage support use in demanding industrial, commercial, infrastructure and critical-power distribution systems.

This model is supplied as a four-pole withdrawable moving part (WMP) and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication. The Ekip G Hi-Touch LSIG release combines Long-time, Short-time, Instantaneous and Ground-fault protection with advanced generator-oriented protection, measurement and power-management capabilities, making the breaker particularly suitable for sophisticated generation and distribution installations.

Key Advantages

  • High-performance 800 A air circuit breaker for demanding low-voltage power systems.
  • Four-pole configuration supports switching and protection of four-conductor circuits.
  • Ekip G Hi-Touch LSIG electronic trip unit combines advanced generator-oriented functionality with comprehensive circuit protection.
  • 66 kA ultimate breaking capacity at 400–440 V AC for systems with substantial prospective fault currents.
  • 50 kA ultimate breaking capacity at 500–690 V AC maintains strong protection at higher system voltages.
  • Ics equal to 100% of Icu supports dependable service short-circuit performance.
  • Long-time, Short-time, Instantaneous and Ground-fault protection cover key overcurrent and earth-fault conditions.
  • Advanced measurement and power-management functionality supports sophisticated electrical-system supervision.
  • Withdrawable construction supports efficient switchboard inspection, servicing and replacement.

Key Features

  • ABB SACE Emax 2 E1.2N air circuit breaker.
  • 800 A rated current.
  • 4-pole configuration.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • 100% rated service short-circuit breaking capacity relative to Icu.
  • 50 kA short-time withstand current for 1 s.
  • 30 kA short-time withstand current for 3 s.
  • Four auxiliary contacts and open/closed breaker position indication.
  • Withdrawable moving-part configuration for switchboard applications.

Advanced Generator and Power-System Protection

The ABB SACE Emax 2 E1.2N provides a robust switching and protection point within low-voltage distribution and generation systems. Its Ekip G Hi-Touch LSIG release combines Long-time overload, Short-time selective, Instantaneous short-circuit and Ground-fault protection with advanced functionality intended for demanding generator and power-management applications.

With an 800 A current rating, up to 66 kA ultimate short-circuit breaking capacity and 50 kA short-time withstand capability for 1 s, the E1.2N offers strong fault-current performance in a compact Emax 2 frame. Its withdrawable construction enables the moving breaker portion to be removed from the corresponding fixed part, supporting maintenance and replacement where system availability and service continuity are important.

Typical Applications

  • Generator protection and generator distribution systems.
  • Main and distribution switchboards.
  • Industrial low-voltage power distribution systems.
  • Commercial and infrastructure electrical distribution.
  • Manufacturing and process-control facilities.
  • Data centres and critical-power installations.
  • Emergency and standby generation systems.
  • Power-management installations requiring advanced LSIG and generator-oriented protection.

Technical Specifications

Series SACE Emax 2
Frame / subtype E1.2N
ABB order code 1SDA072750R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Short-circuit performance level N
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4P
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 50 kA for 1 s
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time (L), Short-time (S), Instantaneous (I), Ground-fault (G)
Integrated ground-fault protection Yes
Version Withdrawable moving part (WMP)
Auxiliary contacts 4
Breaker position indication Open / closed
Power loss 100 W
Dimensions 363.5 × 348 × 271 mm
Standard / approval IEC
Country of origin Italy
EAN / GTIN 8015644766009

Frequently Asked Questions

What is the ABB 1SDA072750R1 used for?

The ABB 1SDA072750R1 is an 800 A four-pole withdrawable air circuit breaker designed for advanced switching, protection and power management in low-voltage distribution and generator applications.

What protection release is fitted to the ABB 1SDA072750R1?

This breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, combining generator-oriented functionality with Long-time, Short-time, Instantaneous and Ground-fault protection.

What does LSIG mean on the Ekip G Hi-Touch trip unit?

LSIG denotes Long-time, Short-time, Instantaneous and Ground-fault protection, providing comprehensive electronic protection against overload, short-circuit and earth-fault conditions.

What is the breaking capacity of the ABB E1.2N 800?

The E1.2N 800 has a rated ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

Is the ABB 1SDA072750R1 a fixed or withdrawable circuit breaker?

The 1SDA072750R1 is a withdrawable moving-part (WMP) circuit breaker designed for use with the appropriate fixed part in an ABB SACE Emax 2 switchboard installation.

Trusted Protection for Advanced Power Systems

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, generator-oriented functionality and flexible system integration to provide dependable switching and power management for demanding industrial, infrastructure and critical-power systems.