Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072750R1 SACE Emax 2 E1.2N 800 A four-pole withdrawable air circuit breaker with Ekip G Hi-Touch LSIG electronic protection for advanced generator and low-voltage power-distribution applications.
£9,073.43
The ABB 1SDA072750R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for advanced protection, switching and power management in low-voltage electrical distribution and generator applications. Rated at 800 A, this four-pole withdrawable breaker combines ABB's compact E1.2N frame with the sophisticated Ekip G Hi-Touch LSIG electronic trip unit, providing comprehensive protection against overload, short-circuit and earth-fault conditions.
The E1.2N performance level provides a rated ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated operational voltage of 690 V AC, 1000 V AC insulation voltage and 12 kV impulse withstand voltage support use in demanding industrial, commercial, infrastructure and critical-power distribution systems.
This model is supplied as a four-pole withdrawable moving part (WMP) and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication. The Ekip G Hi-Touch LSIG release combines Long-time, Short-time, Instantaneous and Ground-fault protection with advanced generator-oriented protection, measurement and power-management capabilities, making the breaker particularly suitable for sophisticated generation and distribution installations.
The ABB SACE Emax 2 E1.2N provides a robust switching and protection point within low-voltage distribution and generation systems. Its Ekip G Hi-Touch LSIG release combines Long-time overload, Short-time selective, Instantaneous short-circuit and Ground-fault protection with advanced functionality intended for demanding generator and power-management applications.
With an 800 A current rating, up to 66 kA ultimate short-circuit breaking capacity and 50 kA short-time withstand capability for 1 s, the E1.2N offers strong fault-current performance in a compact Emax 2 frame. Its withdrawable construction enables the moving breaker portion to be removed from the corresponding fixed part, supporting maintenance and replacement where system availability and service continuity are important.
| Series | SACE Emax 2 |
|---|---|
| Frame / subtype | E1.2N |
| ABB order code | 1SDA072750R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Short-circuit performance level | N |
| Rated current (In) | 800 A |
| Rated uninterrupted current (Iu) | 800 A |
| Number of poles | 4P |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 50 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw) | 50 kA for 1 s |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | Long-time (L), Short-time (S), Instantaneous (I), Ground-fault (G) |
| Integrated ground-fault protection | Yes |
| Version | Withdrawable moving part (WMP) |
| Auxiliary contacts | 4 |
| Breaker position indication | Open / closed |
| Power loss | 100 W |
| Dimensions | 363.5 × 348 × 271 mm |
| Standard / approval | IEC |
| Country of origin | Italy |
| EAN / GTIN | 8015644766009 |
The ABB 1SDA072750R1 is an 800 A four-pole withdrawable air circuit breaker designed for advanced switching, protection and power management in low-voltage distribution and generator applications.
This breaker is fitted with an Ekip G Hi-Touch LSIG electronic trip unit, combining generator-oriented functionality with Long-time, Short-time, Instantaneous and Ground-fault protection.
LSIG denotes Long-time, Short-time, Instantaneous and Ground-fault protection, providing comprehensive electronic protection against overload, short-circuit and earth-fault conditions.
The E1.2N 800 has a rated ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.
The 1SDA072750R1 is a withdrawable moving-part (WMP) circuit breaker designed for use with the appropriate fixed part in an ABB SACE Emax 2 switchboard installation.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, generator-oriented functionality and flexible system integration to provide dependable switching and power management for demanding industrial, infrastructure and critical-power systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.