1SDA072749R1 ABB E1.2N 800 Ekip Hi-Touch LSIG 4P WMP Air Circuit Breaker

1SDA072749R1 ABB E1.2N 800 Ekip Hi-Touch LSIG 4P WMP Air Circuit Breaker

ABB 1SDA072749R1 SACE Emax 2 E1.2N 800 A four-pole withdrawable air circuit breaker with Ekip Hi-Touch LSIG electronic protection, measurement and power-management functionality.

SKU: 1SDA072749R1MPN: 1SDA072749R1
Price
List Price £11,536.16 ex VAT
Your Price (ex VAT) Save 25%
£8,652.12 25% OFF
You save £2,884.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,652.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,652.12

Why Choose the ABB E1.2N 800 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB 1SDA072749R1 is a high-performance SACE Emax 2 E1.2N air circuit breaker designed for advanced protection, switching and power management in low-voltage electrical distribution systems. Rated at 800 A, this four-pole withdrawable breaker combines ABB's compact E1.2N frame with the advanced Ekip Hi-Touch LSIG electronic trip unit, providing comprehensive protection against overload, short-circuit and earth-fault conditions.

The E1.2N performance level delivers a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, the breaker is suited to demanding industrial, commercial and infrastructure distribution networks where high fault-current capability, selectivity and dependable protection are required.

This model is supplied as a four-pole withdrawable moving part (WMP) for connection through the appropriate separate Emax 2 chassis. The Ekip Hi-Touch LSIG release combines Long-time, Short-time, Instantaneous and Ground-fault protection with ABB's advanced measurement and power-management functionality, while four change-over auxiliary contacts and breaker open/closed indication support integration into modern switchboards and automation systems.

Key Advantages

  • High-performance 800 A air circuit breaker for demanding low-voltage distribution systems.
  • Four-pole configuration for switching and protecting four-conductor circuits.
  • Ekip Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • 66 kA ultimate breaking capacity at 380–440 V AC for high prospective fault-current applications.
  • 50 kA breaking capacity at 500–690 V AC extends robust protection to higher-voltage distribution systems.
  • Advanced measurement and power-management functionality supports sophisticated electrical-system supervision.
  • Integrated Ground-fault (G) protection provides protection against earth-fault conditions.
  • Withdrawable construction supports efficient inspection, servicing and replacement.
  • Four change-over auxiliary contacts facilitate status signalling and control-system integration.

Key Features

  • ABB SACE Emax 2 E1.2N air circuit breaker.
  • 800 A rated uninterrupted current.
  • 4-pole configuration.
  • Ekip Hi-Touch LSIG solid-state electronic protection release.
  • Long-time (L) overload protection.
  • Short-time (S) selective short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 66 kA Icu at 380–440 V AC.
  • 50 kA Icu at 500–690 V AC.
  • Overload protection adjustable from 320–800 A.
  • Short-time delayed short-circuit protection adjustable from 480–8000 A.
  • Instantaneous short-circuit protection adjustable from 1200–12000 A.
  • Four change-over auxiliary contacts fitted.
  • Withdrawable moving-part configuration for switchboard applications.

Advanced Protection and Power Management

The ABB SACE Emax 2 E1.2N provides a robust switching and protection point within low-voltage power-distribution systems. Its Ekip Hi-Touch LSIG release combines Long-time overload, Short-time selective, Instantaneous short-circuit and Ground-fault protection, enabling comprehensive protection against the principal overcurrent and earth-fault conditions encountered in industrial and commercial electrical networks.

With an 800 A current rating, up to 66 kA ultimate short-circuit breaking capacity and advanced Ekip Hi-Touch functionality, the breaker is well suited to sophisticated power-management applications. Its withdrawable construction allows the moving breaker portion to be separated from the corresponding fixed chassis, supporting efficient maintenance and replacement where service continuity and system availability are important.

Typical Applications

  • Main and distribution switchboards.
  • Industrial low-voltage power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process-control facilities.
  • Data centres and critical-power installations.
  • Infrastructure and utility distribution systems.
  • Transformer secondary and generator distribution.
  • Power-management systems requiring advanced measurement and LSIG protection.

Technical Specifications

Series SACE Emax 2
Frame / subtype E1.2N
ABB order code 1SDA072749R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Performance level N
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4P
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Trip unit Ekip Hi-Touch LSIG
Release type Solid-state electronic
Protection functions Long-time (L), Short-time (S), Instantaneous (I), Ground-fault (G)
Overload release current setting 320–800 A
Short-time delayed short-circuit release adjustment 480–8000 A
Instantaneous short-circuit release adjustment 1200–12000 A
Integrated earth-fault protection Yes
Version Withdrawable moving part (WMP)
Main-circuit connection Connection via separate chassis part
Auxiliary contacts 4 change-over contacts
Trip contact Yes
Breaker position indication Open / closed
Control element Push button
Motor drive Optional
Degree of protection IP30
Power loss 100 W
Net weight 20 kg
EAN / GTIN 8015644765996

Frequently Asked Questions

What is the ABB 1SDA072749R1 used for?

The ABB 1SDA072749R1 is an 800 A four-pole air circuit breaker designed for advanced switching, protection and power management in low-voltage electrical distribution systems.

What protection release is fitted to the ABB 1SDA072749R1?

This breaker is fitted with an Ekip Hi-Touch LSIG electronic trip unit, providing Long-time, Short-time, Instantaneous and Ground-fault protection together with advanced measurement and power-management functionality.

What does LSIG mean on the Ekip Hi-Touch trip unit?

LSIG denotes Long-time, Short-time, Instantaneous and Ground-fault protection, providing comprehensive protection against overload, short-circuit and earth-fault conditions.

What is the breaking capacity of the ABB E1.2N 800?

The E1.2N 800 has a rated ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC.

Is the ABB 1SDA072749R1 a fixed or withdrawable circuit breaker?

The 1SDA072749R1 is a withdrawable moving-part (WMP) circuit breaker designed for connection through the appropriate separate chassis in an ABB SACE Emax 2 switchboard installation.

Trusted Protection for Advanced Power Systems

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection, electrical measurement and flexible system integration, providing dependable switching and power management for demanding industrial, commercial and critical-power distribution systems.