ABB 1SDA072748R1 SACE Emax 2 E1.2N 800 A four-pole withdrawable air circuit breaker mobile part with Ekip Hi-Touch LSI electronic protection, 690 V rated voltage, 66 kA short-circuit breaking capacity and 50 kA short-time withstand capability.

SKU: 1SDA072748R1MPN: 1SDA072748R1
Price
List Price £10,934.25 ex VAT
Your Price (ex VAT) Save 25%
£8,200.69 25% OFF
You save £2,733.56 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,200.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,200.69

Why Choose the ABB E1.2N 800 Ekip Hi-Touch LSI 4p WMP Air Circuit Breaker?

The ABB 1SDA072748R1 is a SACE Emax 2 E1.2N air circuit breaker (ACB) designed for advanced protection, monitoring and switching in low-voltage electrical distribution systems. Rated at 800 A, this four-pole breaker combines ABB’s compact E1.2N frame with an Ekip Hi-Touch LSI solid-state electronic trip unit providing long-time overload, short-time delayed and instantaneous short-circuit protection.

The Ekip Hi-Touch release is part of ABB’s advanced Ekip electronic protection platform, combining configurable protection with enhanced measurement, monitoring and power-management capabilities. Its LSI protection configuration supports selective coordination between upstream and downstream protective devices while avoiding integrated earth-fault protection where that function is provided separately or is not required.

The 1SDA072748R1 is a four-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 800 A and rated voltage of 690 V. The E1.2N performance level provides a short-circuit breaking capacity of up to 66 kA and a rated short-time withstand current of 50 kA, making this breaker suitable for demanding commercial, industrial and infrastructure distribution systems.

Key Advantages

  • 800 A rated current for low-voltage main and feeder protection.
  • 690 V rated voltage supports a broad range of low-voltage distribution applications.
  • 66 kA breaking capacity provides robust short-circuit interruption performance.
  • 50 kA short-time withstand capability supports selective distribution-system protection.
  • Ekip Hi-Touch LSI electronic trip unit combines advanced protection, measurement and monitoring functionality.
  • Long-time, short-time and instantaneous protection supports effective coordination with upstream and downstream protective devices.
  • Four-pole configuration with 100% neutral-pole current capability suits three-phase four-wire distribution networks.
  • Withdrawable mobile-part construction facilitates isolation, inspection, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 800 A rated current.
  • 690 V rated voltage.
  • Four-pole configuration.
  • 100% neutral-pole current rating.
  • N short-circuit performance level.
  • 66 kA breaking capacity.
  • 50 kA short-time withstand current.
  • Ekip Hi-Touch LSI solid-state electronic trip unit.
  • LSI protection provides long-time overload, short-time delayed and instantaneous short-circuit protection.
  • No integrated earth-fault protection in the LSI configuration.
  • Withdrawable mobile part (WMP) configuration.
  • Four auxiliary contacts fitted as standard on this configuration.
  • Circuit-breaker open/closed position indication.
  • Designed for connection through the corresponding Emax 2 E1.2 fixed part.

Advanced Hi-Touch Selective Protection

The ABB SACE Emax 2 E1.2N combines compact air circuit breaker construction with advanced electronic protection for low-voltage networks requiring reliable overload and short-circuit interruption. With a rated current of 800 A, breaking capacity of up to 66 kA and short-time withstand capability of 50 kA, this configuration provides substantial fault-current performance within ABB’s compact E1.2 frame.

The Ekip Hi-Touch LSI solid-state release provides long-time overload, short-time delayed and instantaneous short-circuit protection. The short-time function supports selective coordination within multi-level distribution systems, while the Hi-Touch platform provides enhanced protection, measurement and power-management capabilities for installations requiring greater visibility and control than a basic electronic trip unit.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Three-phase four-wire electrical distribution systems.
  • Commercial building power distribution.
  • Industrial feeder and distribution protection.
  • Transformer secondary distribution systems.
  • Infrastructure and utility installations.
  • Manufacturing and process facilities.
  • Systems requiring selective short-circuit protection.
  • Advanced power monitoring and energy-management installations.
  • Switchboards requiring withdrawable four-pole circuit breaker construction.

Technical Specifications

Series SACE Emax 2
Frame E1.2
Order code / SKU 1SDA072748R1
EAN 8015644765989
Product type Air circuit breaker
Rated current 800 A
Rated voltage 690 V
Number of poles 4
Neutral-pole current 100% of rated current
Current type AC
Performance level N
Trip unit Ekip Hi-Touch
Release type Solid-state electronic
Protection functions LSI
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection No
Short-circuit breaking capacity 66 kA
Rated short-time withstand current 50 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Execution Withdrawable mobile part
Main circuit connection Connection through corresponding fixed part
Auxiliary contacts 4
Open / closed position indication Yes
Power loss 100 W
Electrical durability at ≤440 V 8000 cycles
Electrical durability at 500–690 V 8000 cycles
Mechanical durability 20000 cycles
Product width 348 mm
Product height 363.5 mm
Product depth 271 mm
Net weight 20 kg

Frequently Asked Questions

What is the ABB 1SDA072748R1?

The ABB 1SDA072748R1 is a four-pole SACE Emax 2 E1.2N withdrawable air circuit breaker mobile part rated at 800 A and equipped with an Ekip Hi-Touch LSI solid-state electronic trip unit.

What are the current and voltage ratings of the ABB E1.2N 1SDA072748R1?

The breaker has a rated current of 800 A and a rated voltage of 690 V, making it suitable for a wide range of commercial and industrial low-voltage distribution systems.

What is the breaking capacity of the ABB E1.2N 800?

The E1.2N 800 provides a short-circuit breaking capacity of up to 66 kA and a rated short-time withstand current of 50 kA, providing robust performance for demanding low-voltage distribution applications.

What does Ekip Hi-Touch LSI mean?

Ekip Hi-Touch is an advanced ABB electronic trip unit offering protection, measurement, monitoring and power-management functionality, while LSI denotes long-time, short-time and instantaneous protection. This configuration does not include integrated earth-fault protection.

Is the ABB 1SDA072748R1 fixed or withdrawable?

The 1SDA072748R1 is a four-pole withdrawable mobile part designed for use with the corresponding Emax 2 E1.2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.

Trusted for Advanced Selective Power Protection

ABB SACE Emax 2 air circuit breakers combine robust short-circuit performance, advanced electronic protection and flexible withdrawable construction for commercial, industrial and infrastructure low-voltage distribution systems requiring dependable selectivity, monitoring and power-management capability.