Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072723R1 SACE Emax 2 E1.2B 800 four-pole withdrawable air circuit breaker moving part with Ekip Dip LSIG electronic protection, 800 A rated current and 42 kA breaking capacity up to 690 V AC.
£3,942.36
The ABB 1SDA072723R1 is a high-performance SACE Emax 2 E1.2B air circuit breaker designed for reliable protection and control of low-voltage electrical distribution systems. Configured as an E1.2B 800 Ekip Dip LSIG 4p WMP, this four-pole withdrawable moving part combines an 800 A rated current with ABB's Ekip Dip LSIG electronic protection release.
As part of the advanced ABB SACE Emax 2 air circuit breaker series, the E1.2B is engineered for industrial, commercial and infrastructure power distribution applications. The Ekip Dip LSIG trip unit provides adjustable long-time, short-time, instantaneous and earth-fault protection, with protection parameters conveniently configured using DIP switches.
The E1.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA across operating voltages from 380 V AC to 690 V AC. With a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V AC and four-pole withdrawable construction, the breaker is well suited to demanding switchboard installations requiring robust circuit protection and straightforward maintenance.
Air circuit breakers such as the ABB SACE Emax 2 E1.2B protect low-voltage electrical distribution systems against overloads, short circuits and earth faults. The E1.2B's 42 kA breaking capacity across a broad range of AC operating voltages provides dependable fault interruption for switchboards, feeders and connected electrical equipment.
The Ekip Dip LSIG electronic trip unit provides adjustable protection while retaining a straightforward DIP-switch configuration interface. Long-time, short-time, instantaneous and earth-fault functions allow the breaker to respond to different electrical fault conditions, supporting selective and dependable protection in modern industrial and commercial distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2B |
| Order code / MPN | 1SDA072723R1 |
| Product type | Air circuit breaker |
| Construction | Withdrawable moving part |
| Number of poles | 4 |
| Rated current | 800 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Frequency | 50 / 60 Hz |
| Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Protection release | Ekip Dip LSIG |
| Release type | Electronic |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Overload protection setting | 0.4–1 × In |
| Short-time selective protection setting | 0.6–10 × In |
| Instantaneous protection setting | 1.5–15 × In |
| Earth-fault protection setting | 0.1–1 × In |
| Protection adjustment | DIP switches |
| Mounting system | Withdrawable |
| Standard | IEC 60947-2 |
| Product family | Emax 2 Air Circuit Breakers |
The ABB 1SDA072723R1 is an Emax 2 air circuit breaker moving part designed to protect and control low-voltage electrical distribution systems against overloads, short circuits and earth faults.
The breaker has a rated current of 800 A, making it suitable for substantial industrial, commercial and infrastructure power distribution loads.
The E1.2B 800 has a rated ultimate short-circuit breaking capacity of 42 kA at operating voltages including 380 V AC, 400–415 V AC, 440 V AC, 500–525 V AC and 690 V AC.
This model is fitted with the ABB Ekip Dip LSIG electronic release, providing adjustable long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection.
The 1SDA072723R1 is a four-pole withdrawable moving part for the Emax 2 E1.2B circuit breaker system and is designed for use with the corresponding fixed part in a low-voltage switchboard.
ABB SACE Emax 2 air circuit breakers combine dependable fault interruption with configurable electronic protection, providing robust circuit protection for demanding industrial, commercial and infrastructure low-voltage distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.