ABB 1SDA072722R1 E1.2B 800 Ekip Dip LSI 4p WMP is a four-pole 800 A SACE Emax 2 withdrawable air circuit breaker with Ekip Dip LSI electronic protection, a 690 V AC rated operational voltage and 42 kA ultimate short-circuit breaking capacity.
£3,475.90
The ABB E1.2B 800 Ekip Dip LSI 4p WMP, order code 1SDA072722R1, is a compact SACE Emax 2 air circuit breaker (ACB) designed for reliable protection and control in low-voltage power distribution systems. This four-pole withdrawable breaker combines a rated current of 800 A with the Ekip Dip LSI electronic trip unit for long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E1.2B frame provides a space-efficient solution for industrial, commercial and infrastructure switchboards requiring dependable circuit protection. Its Ekip Dip LSI electronic release adds adjustable short-time protection to the standard overload and instantaneous functions, helping engineers achieve improved selectivity and coordination between protective devices.
With a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 42 kA across common low-voltage operating voltages up to 690 V AC, the 1SDA072722R1 provides dependable fault interruption performance. Its four-pole withdrawable moving-part configuration supports four-pole switching and convenient inspection, servicing and maintenance within compatible ABB SACE Emax 2 switchgear.
Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical distribution systems against damaging overload and short-circuit conditions. The E1.2B platform combines a compact frame with an 800 A current rating and 42 kA ultimate short-circuit breaking capacity, providing dependable protection for industrial, commercial and infrastructure switchboards.
The Ekip Dip LSI electronic trip unit provides long-time overload protection, short-time delayed short-circuit protection and instantaneous short-circuit protection. The adjustable short-time function supports selective coordination between protective devices, while straightforward DIP-switch settings and withdrawable construction make the 1SDA072722R1 practical for commissioning, operation and ongoing switchboard maintenance.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA072722R1 |
| Product type | Air circuit breaker |
| Frame | E1.2B |
| Performance level | B |
| Rated current | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Frequency | 50/60 Hz |
| Number of poles | 4 |
| Trip unit | Ekip Dip LSI |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Ultimate short-circuit breaking capacity at 380 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 400/415 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 440 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 500/525 V AC | 42 kA |
| Ultimate short-circuit breaking capacity at 690 V AC | 42 kA |
| Long-time overload adjustment | 0.4–1 × In |
| Short-time protection adjustment | 0.6–10 × In |
| Instantaneous protection adjustment | 1.5–15 × In |
| Earth-fault protection | No integrated G protection |
| Protection setting method | DIP switches |
| Installation type | Withdrawable moving part |
| Breaker configuration | Mobile part of withdrawable circuit breaker |
| Application | Low-voltage power distribution |
| Product standard | IEC 60947-2 |
The ABB 1SDA072722R1 is a SACE Emax 2 air circuit breaker designed for protection and control of low-voltage power distribution systems requiring an 800 A four-pole withdrawable breaker with electronic LSI protection.
The E1.2B 800 configuration has a rated current of 800 A.
The Ekip Dip LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E1.2B 800 has an ultimate short-circuit breaking capacity of 42 kA at 380 V AC, 400/415 V AC, 440 V AC, 500/525 V AC and 690 V AC.
Yes. The 1SDA072722R1 is a four-pole withdrawable moving part designed for use with the appropriate ABB SACE Emax 2 fixed part.
ABB SACE Emax 2 air circuit breakers combine compact construction, dependable electronic protection, selective coordination capabilities and service-friendly withdrawable design for demanding industrial, commercial and infrastructure power distribution systems.