1SDA072687R1 ABB E1.2B 630 Ekip G Touch LSIG 4P Air Circuit Breaker

1SDA072687R1 ABB E1.2B 630 Ekip G Touch LSIG 4P Air Circuit Breaker

ABB 1SDA072687R1 SACE Emax 2 E1.2B 630 four-pole withdrawable air circuit breaker moving part with Ekip G Touch LSIG electronic protection, 630 A rated current and 42 kA breaking capacity.

SKU: 1SDA072687R1MPN: 1SDA072687R1
Price
List Price £7,844.62 ex VAT
Your Price (ex VAT) Save 25%
£5,883.47 25% OFF
You save £1,961.16 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,883.47
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,883.47

Why Choose the ABB 1SDA072687R1 Emax 2 Air Circuit Breaker?

The ABB 1SDA072687R1 is a high-performance SACE Emax 2 E1.2B air circuit breaker designed for protection, control and management of low-voltage electrical distribution and generator systems. Configured as an E1.2B 630 Ekip G Touch LSIG 4p WMP, this four-pole withdrawable moving part combines a 630 A rated current with ABB's advanced Ekip G Touch electronic protection release.

As part of the ABB SACE Emax 2 range, the breaker provides comprehensive protection against overloads, selective short circuits, instantaneous short circuits and earth faults. The Ekip G Touch LSIG trip unit is specifically equipped with generator protection functionality and advanced electrical measurement capabilities, making this model particularly suitable for generating sets and sophisticated power distribution installations.

The E1.2B performance level provides a rated ultimate short-circuit breaking capacity of 42 kA across key AC operating voltages up to 690 V AC. Its withdrawable four-pole construction is designed for use with the appropriate Emax 2 fixed part, supporting convenient isolation, inspection and maintenance within low-voltage switchboards.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution and generator protection.
  • 630 A rated current for industrial and commercial electrical installations.
  • 42 kA ultimate short-circuit breaking capacity for robust fault protection.
  • Advanced Ekip G Touch LSIG electronic protection release.
  • Integrated long-time, short-time, instantaneous and earth-fault protection functions.
  • Four-pole withdrawable moving-part design for switchboard applications.
  • Rated operational voltage up to 690 V AC.
  • Generator-specific protection functions and integrated measurement capabilities.

Key Features

  • ABB SACE Emax 2 E1.2B series.
  • 630 A rated uninterrupted current.
  • 4-pole configuration.
  • Ekip G Touch LSIG electronic release.
  • 42 kA Icu at 400–440 V AC.
  • 42 kA short-time withstand current for 1 s.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • Adjustable overload, selective short-circuit, instantaneous and earth-fault protection.
  • Integrated Ekip Measuring Pro measurement functionality.
  • Touchscreen interface for protection configuration and monitoring.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.
  • Withdrawable moving-part construction for use with a corresponding fixed part.

Advanced Generator and Circuit Protection

Air circuit breakers such as the ABB SACE Emax 2 E1.2B protect low-voltage electrical systems against overloads, short circuits and earth faults while providing reliable switching and isolation. The E1.2B's 42 kA breaking capacity enables it to interrupt substantial prospective fault currents and protect switchboards, conductors, generators and connected equipment.

The Ekip G Touch LSIG electronic trip unit is designed to meet the demanding protection requirements of generator and power distribution applications. Adjustable protection settings, generator-specific functions and integrated Ekip Measuring Pro capabilities allow the breaker to provide sophisticated protection, measurement and system supervision within modern electrical installations.

Typical Applications

  • Generator and generating-set protection.
  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Manufacturing and process facilities.
  • Critical infrastructure and standby power systems.
  • Power management and energy monitoring installations.
  • Switchboards requiring four-pole withdrawable circuit breakers.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA072687R1
Product type Air circuit breaker
Construction Withdrawable moving part
Number of poles 4
Rated current (In) 630 A
Rated uninterrupted current (Iu) 630 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Rated short-time withstand current (Icw) 42 kA for 1 s
Protection release Ekip G Touch LSIG
Release type Electronic solid-state
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Overload protection setting 0.4–1 × In
Selective short-circuit protection setting 0.6–10 × In
Instantaneous short-circuit protection setting 1.5–15 × In
Earth-fault protection setting 0.1–1 × In
Measurement Ekip Measuring Pro integrated
Configuration interface Touchscreen display
Auxiliary contacts 4
Application Generator and low-voltage distribution protection
Product net weight approx. 20 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072687R1 used for?

The ABB 1SDA072687R1 is an Emax 2 air circuit breaker moving part designed to protect generators and low-voltage electrical distribution systems against overloads, short circuits and earth faults.

What is the current rating of the ABB E1.2B 1SDA072687R1?

The breaker has a rated current of 630 A and is designed for use in industrial, commercial and generator power distribution applications.

What breaking capacity does the E1.2B 630 provide?

The E1.2B configuration has a rated ultimate short-circuit breaking capacity of 42 kA at AC operating voltages including 400–415 V AC, 440 V AC and 690 V AC.

What protection release is fitted to 1SDA072687R1?

This model is fitted with the ABB Ekip G Touch LSIG electronic release, providing adjustable long-time, short-time, instantaneous and earth-fault protection together with generator-specific protection and measurement functionality.

Is the ABB 1SDA072687R1 a fixed or withdrawable circuit breaker?

The 1SDA072687R1 is a four-pole withdrawable moving part for the Emax 2 E1.2B circuit breaker system and is designed for installation with the corresponding fixed part in a low-voltage switchboard.

Trusted for Generator and Power Distribution Protection

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, measurement and switching capabilities for dependable generator and low-voltage power distribution applications in modern industrial and commercial electrical systems.