Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072685R1 SACE Emax 2 E1.2B 630 A four-pole withdrawable air circuit breaker mobile part with Ekip Touch LSI electronic protection, 690 V AC rated operational voltage and 42 kA short-circuit breaking capacity.
£3,250.19
The ABB 1SDA072685R1 is a compact SACE Emax 2 E1.2B air circuit breaker (ACB) designed for reliable protection, switching and monitoring in low-voltage electrical distribution systems. Rated at 630 A, this four-pole breaker combines ABB’s E1.2B frame with an advanced Ekip Touch LSI electronic trip unit providing long-time overload, short-time delayed and instantaneous short-circuit protection.
As part of the ABB SACE Emax 2 air circuit breaker series, the E1.2B combines compact construction with electronic protection and flexible switchboard integration. The Ekip Touch release provides an intuitive touchscreen interface together with protection, measurement and monitoring capabilities, while the four-pole configuration enables switching of the neutral conductor together with all three phases.
The 1SDA072685R1 is a four-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 630 A and rated operational voltage of 690 V AC. The E1.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 400–690 V AC and a rated short-time withstand current of 42 kA for 1 second, making it suitable for commercial, industrial and infrastructure distribution systems requiring dependable selective protection.
The ABB SACE Emax 2 E1.2B provides compact air circuit breaker protection for low-voltage networks requiring reliable overload and short-circuit interruption. With a rated current of 630 A, an ultimate breaking capacity of 42 kA and a short-time withstand capability of 42 kA for 1 second, this configuration is well suited to distribution systems where compact switchgear, selectivity and continuity of supply are important.
The Ekip Touch LSI electronic trip unit provides adjustable long-time overload, short-time delayed and instantaneous short-circuit protection. Its short-time function supports selective coordination within multi-level distribution systems, while the touchscreen interface simplifies protection configuration and monitoring. The LSI configuration does not include integrated earth-fault protection.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2 |
| Order code / SKU | 1SDA072685R1 |
| EAN | 8015644765354 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 630 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 4 |
| Neutral pole current | 100% of Iu |
| Current type | AC |
| Performance level | B |
| Trip unit | Ekip Touch |
| Release type | Electronic / solid-state |
| Protection functions | LSI |
| Overload release adjustment range | 252–630 A |
| Short-time delayed short-circuit adjustment range | 378–6300 A |
| Instantaneous short-circuit adjustment range | 945–9450 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw, 1 s) | 42 kA |
| Rated short-time withstand current (Icw, 3 s) | 24 kA |
| Integrated earth-fault protection | No |
| Execution | Withdrawable mobile part |
| Main circuit connection | Connection through corresponding fixed part |
| Auxiliary contacts | 4 |
| Open / closed position indication | Yes |
| Power loss | 62 W |
| Electrical durability | 8000 operations |
| Mechanical durability | 20000 operations |
| Product dimensions (W × H × D) | 348 × 363.5 × 271 mm |
| Standard | IEC 60947-2 |
The ABB 1SDA072685R1 is a four-pole SACE Emax 2 E1.2B withdrawable air circuit breaker mobile part rated at 630 A and equipped with an Ekip Touch LSI electronic trip unit.
The breaker has a rated uninterrupted current of 630 A and a rated operational voltage of 690 V AC.
The E1.2B 630 provides an ultimate short-circuit breaking capacity of 42 kA at key operating voltages from 400 V AC through 690 V AC, together with a rated short-time withstand current of 42 kA for 1 second.
Ekip Touch is ABB’s electronic trip unit with touchscreen-based protection, measurement and monitoring functionality, while LSI denotes long-time, short-time and instantaneous protection. This configuration does not include integrated earth-fault protection.
The 1SDA072685R1 is a four-pole withdrawable mobile part designed for use with the corresponding Emax 2 E1.2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.
ABB SACE Emax 2 air circuit breakers combine compact construction, configurable electronic protection and flexible withdrawable switchboard integration for commercial, industrial and infrastructure low-voltage power distribution systems.