1SDA072679R1 ABB E1.2N 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker

1SDA072679R1 ABB E1.2N 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker

ABB 1SDA072679R1 E1.2N 250 Ekip Hi-Touch LSIG 4p WMP is a four-pole 250 A SACE Emax 2 withdrawable air circuit breaker with Ekip Hi-Touch LSIG electronic protection, 66 kA ultimate short-circuit breaking capacity at 380–440 V AC and 50 kA short-time withstand current for 1 s.

SKU: 1SDA072679R1MPN: 1SDA072679R1
Price
List Price £11,536.16 ex VAT
Your Price (ex VAT) Save 25%
£8,652.12 25% OFF
You save £2,884.04 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,652.12
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,652.12

Why Choose the ABB E1.2N 250 Ekip Hi-Touch LSIG 4p WMP Air Circuit Breaker?

The ABB E1.2N 250 Ekip Hi-Touch LSIG 4p WMP, order code 1SDA072679R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, measurement and control in low-voltage power distribution systems. This four-pole withdrawable breaker combines a rated current of 250 A with the advanced Ekip Hi-Touch LSIG electronic trip unit for comprehensive overload, short-circuit and earth-fault protection.

The E1.2N frame combines compact construction with dependable fault interruption performance for industrial, commercial and infrastructure electrical systems. Its Ekip Hi-Touch LSIG electronic release provides long-time, short-time, instantaneous and earth-fault protection together with advanced electrical measurement and network analysis capabilities.

The 1SDA072679R1 provides an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC, with 50 kA at 500–690 V AC, and a rated short-time withstand current of 50 kA for 1 s. Its four-pole withdrawable moving-part configuration supports neutral switching and efficient inspection, servicing and maintenance within compatible ABB SACE Emax 2 switchgear.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 250 A rated current with a compact E1.2 frame design.
  • 66 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • 50 kA short-time withstand current for 1 s supports protection coordination and selectivity.
  • Ekip Hi-Touch LSIG electronic trip unit provides overload, short-time, instantaneous and earth-fault protection.
  • Integrated advanced measurement and network analysis capabilities for monitoring electrical system performance.
  • Four-pole withdrawable design supports neutral switching and service-friendly switchgear construction.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 250 A rated current.
  • Four-pole configuration.
  • N breaking-capacity performance level.
  • 66 kA ultimate short-circuit breaking capacity at 380–440 V AC.
  • 50 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 50 kA rated short-time withstand current for 1 s.
  • Ekip Hi-Touch LSIG electronic protection release.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • Integrated Ekip Measuring Pro measurement functionality and Network Analyzer capability.
  • Touchscreen interface for protection configuration, measurements and breaker information.
  • Withdrawable moving-part construction for compatible ABB SACE Emax 2 switchgear assemblies.

Advanced LSIG Protection and Power Monitoring

Air circuit breakers such as the ABB SACE Emax 2 provide essential protection for low-voltage electrical distribution systems against overload, short-circuit and earth-fault conditions. The E1.2N platform combines a compact frame with a rated current of 250 A, a breaking capacity of up to 66 kA and a rated short-time withstand current of 50 kA for 1 s, supporting reliable protection and selective coordination.

The Ekip Hi-Touch LSIG electronic trip unit adds advanced measurement and monitoring to comprehensive long-time, short-time, instantaneous and earth-fault protection. Integrated measurement and network analysis capabilities make the 1SDA072679R1 particularly suitable for installations where circuit protection, power-quality information and detailed electrical monitoring are required from the same breaker platform.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Industrial electrical distribution systems.
  • Commercial building switchboards.
  • Manufacturing and process plant electrical systems.
  • Data centres and critical infrastructure distribution.
  • Four-wire networks requiring switched-neutral and earth-fault protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA072679R1
Product type Air circuit breaker
Frame E1.2N
Performance level N
Rated current 250 A
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Frequency 50/60 Hz
Number of poles 4
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Ultimate short-circuit breaking capacity at 380–440 V AC 66 kA
Ultimate short-circuit breaking capacity at 500–690 V AC 50 kA
Rated short-time withstand current 50 kA for 1 s
Long-time overload adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Earth-fault protection adjustment 0.1–1 × In
Earth-fault protection Yes
Measurement Ekip Measuring Pro
Network analysis Integrated Network Analyzer functionality
Installation type Withdrawable moving part
Breaker configuration Mobile part of withdrawable circuit breaker
Application Low-voltage power distribution
Product standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072679R1 used for?

The ABB 1SDA072679R1 is a SACE Emax 2 air circuit breaker designed for low-voltage power distribution applications requiring advanced electronic protection, measurement, network analysis and four-pole switching.

What is the rated current of the ABB E1.2N 250?

The E1.2N 250 configuration has a rated current of 250 A.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, with advanced measurement and network analysis capabilities.

What is the breaking capacity of the ABB 1SDA072679R1?

The breaker has an ultimate short-circuit breaking capacity of 66 kA at 380–440 V AC and 50 kA at 500–690 V AC, with a rated short-time withstand current of 50 kA for 1 s.

Is the ABB 1SDA072679R1 a four-pole withdrawable circuit breaker?

Yes. The 1SDA072679R1 is a four-pole withdrawable moving part designed for use with the appropriate ABB SACE Emax 2 fixed part, providing switching of all four poles within the breaker configuration.

Trusted Protection and Monitoring for Low-Voltage Distribution

ABB SACE Emax 2 air circuit breakers combine dependable fault interruption, advanced electronic protection, electrical measurement and service-friendly withdrawable construction for demanding industrial, commercial and infrastructure power distribution systems.