ABB 1SDA072672R1 SACE Emax 2 E1.2N 250 A four-pole withdrawable air circuit breaker mobile part with Ekip Dip LSI electronic protection, 66 kA short-circuit breaking capacity at 440 V AC and 50 kA short-time withstand capability.

SKU: 1SDA072672R1MPN: 1SDA072672R1
Price
List Price £7,423.31 ex VAT
Your Price (ex VAT) Save 25%
£5,567.48 25% OFF
You save £1,855.83 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,567.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,567.48

Why Choose the ABB E1.2N 250 Ekip Dip LSI 4p WMP Air Circuit Breaker?

The ABB 1SDA072672R1 is a SACE Emax 2 E1.2N air circuit breaker (ACB) designed for reliable protection and switching in low-voltage electrical distribution systems. Rated at 250 A, this four-pole breaker combines ABB’s compact E1.2N frame with an Ekip Dip LSI electronic trip unit providing long-time overload, short-time delayed and instantaneous short-circuit protection.

As part of the ABB SACE Emax 2 air circuit breaker series, the E1.2N combines compact construction with high short-circuit performance and flexible switchboard integration. Its four-pole configuration enables switching and isolation of the neutral conductor together with the three phases, making it particularly suitable for three-phase four-wire distribution networks.

The 1SDA072672R1 is a four-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 250 A. The E1.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 440 V AC and a rated short-time withstand current of 50 kA for 1 second, supporting dependable protection and selective coordination in commercial, industrial and infrastructure power distribution systems.

Key Advantages

  • 250 A rated uninterrupted current for low-voltage distribution and feeder protection.
  • 66 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 50 kA short-time withstand current for 1 second supports selective protection strategies.
  • Ekip Dip LSI electronic trip unit provides adjustable overload and short-circuit protection.
  • Long-time, short-time and instantaneous protection enables improved coordination with upstream and downstream protective devices.
  • Four-pole configuration enables switching and isolation of the neutral conductor together with the three phases.
  • Withdrawable mobile-part construction facilitates isolation, inspection, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E1.2N series.
  • 250 A rated uninterrupted current.
  • Four-pole configuration.
  • N performance level.
  • 66 kA Icu at 440 V AC.
  • 50 kA Icw for 1 second.
  • Ekip Dip LSI electronic trip unit.
  • LSI protection provides long-time overload, short-time delayed and instantaneous short-circuit protection.
  • Short-time protection supports selective coordination between protective devices.
  • No integrated earth-fault protection in the LSI configuration.
  • Withdrawable mobile part (WMP) configuration.
  • Designed for use with the corresponding Emax 2 E1.2 fixed part.
  • Suitable for three-phase four-wire low-voltage distribution systems.

Selective Four-Pole Circuit Protection

The ABB SACE Emax 2 E1.2N provides compact air circuit breaker protection for low-voltage networks requiring dependable interruption of overload and short-circuit currents. With a rated current of 250 A, an ultimate breaking capacity of 66 kA at 440 V AC and a short-time withstand current of 50 kA for 1 second, this configuration combines compact dimensions with substantial fault-current capability.

The Ekip Dip LSI electronic trip unit provides long-time overload, short-time delayed and instantaneous short-circuit protection. The additional short-time protection function compared with an LI release supports improved selectivity and coordination within multi-level distribution systems, while the four-pole arrangement enables simultaneous switching and isolation of phase and neutral conductors.

Typical Applications

  • Low-voltage main and sub-distribution switchboards.
  • Three-phase four-wire electrical distribution systems.
  • Commercial building power distribution.
  • Industrial feeder and distribution protection.
  • Transformer secondary distribution systems.
  • Infrastructure and utility installations.
  • Systems requiring selective short-circuit protection.
  • Switchboards requiring withdrawable four-pole circuit breaker construction.

Technical Specifications

Series SACE Emax 2
Frame E1.2
Order code / SKU 1SDA072672R1
Product type Air circuit breaker
Rated uninterrupted current (Iu) 250 A
Number of poles 4
Performance level N
Trip unit Ekip Dip
Release type Electronic
Protection functions LSI
Long-time overload protection Yes
Short-time delayed short-circuit protection Yes
Instantaneous short-circuit protection Yes
Integrated earth-fault protection No
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Rated short-time withstand current (Icw, 1 s) 50 kA
Execution Withdrawable mobile part
Main circuit connection Connection through corresponding fixed part
Application Power distribution
Breaker family Emax 2
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA072672R1?

The ABB 1SDA072672R1 is a four-pole SACE Emax 2 E1.2N withdrawable air circuit breaker mobile part rated at 250 A and equipped with an Ekip Dip LSI electronic trip unit.

What is the rated current of the ABB E1.2N 1SDA072672R1?

The breaker has a rated uninterrupted current of 250 A and is designed for low-voltage power distribution and circuit protection applications.

What is the breaking capacity of the ABB E1.2N 250?

The E1.2N 250 provides an ultimate short-circuit breaking capacity of 66 kA at 440 V AC and a rated short-time withstand current of 50 kA for 1 second.

What does Ekip Dip LSI mean?

Ekip Dip is ABB’s electronic trip unit, while LSI denotes long-time, short-time and instantaneous protection. The short-time function supports selective circuit coordination, while this LSI configuration does not include integrated earth-fault protection.

Is the ABB 1SDA072672R1 fixed or withdrawable?

The 1SDA072672R1 is a four-pole withdrawable mobile part designed for use with the corresponding Emax 2 E1.2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.

Trusted for Selective Low-Voltage Power Protection

ABB SACE Emax 2 air circuit breakers combine compact construction, robust short-circuit performance and configurable electronic protection for commercial, industrial and infrastructure low-voltage power distribution systems requiring reliable selectivity and flexible withdrawable switchboard integration.