ABB 1SDA072642R1 SACE Emax 2 E6.2H 6300 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI solid-state electronic release for selective high-current low-voltage AC distribution protection.
£36,557.67
The ABB 1SDA072642R1 is a high-current SACE Emax 2 E6.2H 6300 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. Configured as an E6.2H 6300 Ekip Dip LSI 3p WMP, it combines a 6300 A rated uninterrupted current, three-pole construction and ABB's Ekip Dip solid-state electronic release with LSI protection functions.
The E6.2H is engineered for major industrial, infrastructure and critical-power distribution systems requiring exceptional current-carrying capability and high short-circuit performance. This 6300 A H-performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA and a rated short-time withstand current of 100 kA for 1 s, supporting installations with very high prospective fault currents.
The Ekip Dip LSI trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function supports selective coordination with downstream protective devices, while the three-pole withdrawable moving-part (WMP) architecture is designed for installation with the appropriate Emax 2 fixed part, allowing efficient isolation, inspection, servicing and replacement.
Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage networks against overload and short-circuit conditions. With a 6300 A rated uninterrupted current, 100 kA ultimate short-circuit breaking capacity and 100 kA short-time withstand capability for 1 s, the 1SDA072642R1 is designed for critical distribution positions carrying exceptionally high currents and exposed to substantial prospective fault levels.
The Ekip Dip LSI release provides three complementary electronic protection functions. Long-time protection responds to sustained overloads, short-time protection provides a delayed short-circuit stage that can support selectivity with downstream devices, and instantaneous protection rapidly interrupts severe short circuits. Combined with the robust E6.2H frame and withdrawable architecture, this configuration provides dependable selective protection and practical maintainability for sophisticated high-current switchboards.
| Series | SACE Emax 2 |
|---|---|
| Frame | E6.2 |
| Performance level | H |
| Model / configuration | E6.2H 6300 Ekip Dip LSI 3p WMP |
| ABB order code | 1SDA072642R1 |
| EAN | 8015644764920 |
| Product type | Air circuit breaker moving part |
| Current type | AC |
| Rated uninterrupted current (Iu) | 6300 A |
| Number of poles | 3 |
| Trip unit | Ekip Dip LSI |
| Trip unit type | Solid-state electronic |
| Protection functions | Long-time, short-time and instantaneous (LSI) |
| Long-time protection | L |
| Short-time protection | S |
| Instantaneous protection | I |
| Integrated earth-fault protection | No |
| Rated ultimate short-circuit breaking capacity (Icu) | 100 kA |
| Rated short-time withstand current (Icw), 1 s | 100 kA |
| Auxiliary contacts | 4 |
| Circuit-breaker position indication | Open / closed |
| Execution | Withdrawable moving part (WMP) |
| Fixed part | Separate matching Emax 2 fixed part required |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA072642R1 is a SACE Emax 2 E6.2H 6300 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI solid-state electronic release.
The breaker has a rated uninterrupted current of 6300 A, making it suitable for exceptionally high-current low-voltage AC power distribution circuits.
The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function can support selective coordination between upstream and downstream protective devices.
The E6.2H 6300 provides a rated ultimate short-circuit breaking capacity of 100 kA and a rated short-time withstand current of 100 kA for 1 s, providing substantial fault-current capability for high-current distribution systems.
WMP identifies the withdrawable moving-part execution. The breaker moving part is designed for use with a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.
ABB SACE Emax 2 air circuit breakers combine exceptional current-carrying capability, high short-circuit performance, selective electronic protection and flexible withdrawable architecture for demanding industrial, commercial and infrastructure power distribution systems.