1SDA072642R1 ABB E6.2H 6300 Ekip Dip LSI 3P WMP Air Circuit Breaker

1SDA072642R1 ABB E6.2H 6300 Ekip Dip LSI 3P WMP Air Circuit Breaker

ABB 1SDA072642R1 SACE Emax 2 E6.2H 6300 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI solid-state electronic release for selective high-current low-voltage AC distribution protection.

SKU: 1SDA072642R1MPN: 1SDA072642R1
Price
List Price £48,743.56 ex VAT
Your Price (ex VAT) Save 25%
£36,557.67 25% OFF
You save £12,185.89 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £36,557.67
Trade pricing is personalised to your account

Manufacturer Lead Time

£36,557.67

Why Choose the ABB 1SDA072642R1 E6.2H 6300 Ekip Dip LSI Air Circuit Breaker?

The ABB 1SDA072642R1 is a high-current SACE Emax 2 E6.2H 6300 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. Configured as an E6.2H 6300 Ekip Dip LSI 3p WMP, it combines a 6300 A rated uninterrupted current, three-pole construction and ABB's Ekip Dip solid-state electronic release with LSI protection functions.

The E6.2H is engineered for major industrial, infrastructure and critical-power distribution systems requiring exceptional current-carrying capability and high short-circuit performance. This 6300 A H-performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA and a rated short-time withstand current of 100 kA for 1 s, supporting installations with very high prospective fault currents.

The Ekip Dip LSI trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function supports selective coordination with downstream protective devices, while the three-pole withdrawable moving-part (WMP) architecture is designed for installation with the appropriate Emax 2 fixed part, allowing efficient isolation, inspection, servicing and replacement.

Key Advantages

  • High-current ABB SACE Emax 2 E6.2H air circuit breaker moving part.
  • 6300 A rated uninterrupted current for major low-voltage power distribution circuits.
  • Ekip Dip LSI solid-state electronic release provides overload and two-stage short-circuit protection.
  • Short-time protection supports selective coordination between upstream and downstream protective devices.
  • 100 kA ultimate short-circuit breaking capacity for demanding high-fault-level networks.
  • 100 kA short-time withstand current for 1 s supports selective high-current distribution architectures.
  • Supplied with four auxiliary contacts for breaker status and control integration.
  • Open/closed breaker-position indication supports clear operational status monitoring.
  • Three-pole withdrawable construction supports efficient isolation, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E6.2 frame.
  • H short-circuit performance level.
  • 6300 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip Dip LSI solid-state electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 100 kA ultimate short-circuit breaking capacity.
  • 100 kA short-time withstand current for 1 s.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.
  • Withdrawable moving-part (WMP) execution.
  • Designed for connection to a separate matching Emax 2 fixed part.
  • Suitable for high-current low-voltage AC power distribution.

Selective LSI Protection for 6300 A Power Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage networks against overload and short-circuit conditions. With a 6300 A rated uninterrupted current, 100 kA ultimate short-circuit breaking capacity and 100 kA short-time withstand capability for 1 s, the 1SDA072642R1 is designed for critical distribution positions carrying exceptionally high currents and exposed to substantial prospective fault levels.

The Ekip Dip LSI release provides three complementary electronic protection functions. Long-time protection responds to sustained overloads, short-time protection provides a delayed short-circuit stage that can support selectivity with downstream devices, and instantaneous protection rapidly interrupts severe short circuits. Combined with the robust E6.2H frame and withdrawable architecture, this configuration provides dependable selective protection and practical maintainability for sophisticated high-current switchboards.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Large industrial power distribution systems.
  • Transformer secondary protection.
  • High-current distribution feeder protection.
  • Data centres and critical-power installations.
  • Large commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Utility and energy distribution installations.
  • Systems requiring selective coordination between upstream and downstream protection.
  • Withdrawable switchboards requiring 6300 A LSI protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2
Performance level H
Model / configuration E6.2H 6300 Ekip Dip LSI 3p WMP
ABB order code 1SDA072642R1
EAN 8015644764920
Product type Air circuit breaker moving part
Current type AC
Rated uninterrupted current (Iu) 6300 A
Number of poles 3
Trip unit Ekip Dip LSI
Trip unit type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection L
Short-time protection S
Instantaneous protection I
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Auxiliary contacts 4
Circuit-breaker position indication Open / closed
Execution Withdrawable moving part (WMP)
Fixed part Separate matching Emax 2 fixed part required
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072642R1?

The ABB 1SDA072642R1 is a SACE Emax 2 E6.2H 6300 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI solid-state electronic release.

What is the rated current of the ABB 1SDA072642R1?

The breaker has a rated uninterrupted current of 6300 A, making it suitable for exceptionally high-current low-voltage AC power distribution circuits.

What protection functions does the Ekip Dip LSI trip unit provide?

The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function can support selective coordination between upstream and downstream protective devices.

What is the short-circuit performance of the E6.2H 6300?

The E6.2H 6300 provides a rated ultimate short-circuit breaking capacity of 100 kA and a rated short-time withstand current of 100 kA for 1 s, providing substantial fault-current capability for high-current distribution systems.

What does WMP mean on the ABB E6.2H 6300?

WMP identifies the withdrawable moving-part execution. The breaker moving part is designed for use with a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.

Trusted Selective Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine exceptional current-carrying capability, high short-circuit performance, selective electronic protection and flexible withdrawable architecture for demanding industrial, commercial and infrastructure power distribution systems.