1SDA072641R1 ABB E6.2H 6300 Ekip Dip LI 3P WMP Air Circuit Breaker

1SDA072641R1 ABB E6.2H 6300 Ekip Dip LI 3P WMP Air Circuit Breaker

ABB 1SDA072641R1 SACE Emax 2 E6.2H 6300 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LI electronic trip unit for high-current low-voltage AC distribution protection.

SKU: 1SDA072641R1MPN: 1SDA072641R1
Price
List Price £48,314.78 ex VAT
Your Price (ex VAT) Save 25%
£36,236.09 25% OFF
You save £12,078.70 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £36,236.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£36,236.09

Why Choose the ABB 1SDA072641R1 E6.2H 6300 Ekip Dip LI Air Circuit Breaker?

The ABB 1SDA072641R1 is a high-current SACE Emax 2 E6.2H 6300 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. Configured as an E6.2H 6300 Ekip Dip LI 3p WMP, it combines a 6300 A rated uninterrupted current, three-pole construction and ABB's Ekip Dip electronic trip unit with LI protection functions.

The E6.2H is engineered for major industrial, infrastructure and critical-power distribution systems requiring substantial current-carrying and short-circuit performance. This 6300 A H-performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s.

The Ekip Dip LI solid-state electronic trip unit provides long-time overload and instantaneous short-circuit protection for straightforward high-current circuit protection. Its three-pole withdrawable moving-part (WMP) architecture is designed for installation with the appropriate Emax 2 fixed part, allowing the breaker to be isolated and withdrawn for inspection, maintenance or replacement.

Key Advantages

  • High-current ABB SACE Emax 2 E6.2H air circuit breaker moving part.
  • 6300 A rated uninterrupted current for major low-voltage distribution circuits.
  • Ekip Dip LI electronic trip unit provides dependable overload and instantaneous short-circuit protection.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding high-current distribution architectures.
  • Electronic long-time protection provides adjustable overload protection appropriate to the connected distribution system.
  • Instantaneous protection rapidly interrupts severe short-circuit conditions.
  • Three-pole withdrawable construction supports isolation, inspection and efficient switchboard maintenance.
  • Well suited to main incomers, transformer secondaries and high-current distribution feeders.

Key Features

  • ABB SACE Emax 2 E6.2 frame.
  • H short-circuit performance level.
  • 6300 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip Dip LI solid-state electronic trip unit.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Withdrawable moving-part (WMP) execution.
  • Designed for connection to a separate matching Emax 2 fixed part.
  • Suitable for high-current low-voltage power distribution installations.

Reliable LI Protection for 6300 A Power Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage electrical networks against overload and short-circuit conditions. With a 6300 A rated uninterrupted current, 100 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA short-time withstand capability for 1 s, the 1SDA072641R1 is designed for critical distribution positions carrying exceptionally high currents.

The Ekip Dip LI trip unit provides two fundamental electronic protection functions. Long-time protection responds to sustained overload conditions, while instantaneous protection rapidly trips the breaker when severe short-circuit currents occur. Combined with the robust E6.2H frame and withdrawable architecture, this configuration provides dependable protection together with practical maintainability for large high-current switchboards.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Large industrial power distribution systems.
  • Transformer secondary protection.
  • High-current distribution feeder protection.
  • Data centres and critical-power installations.
  • Large commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Utility and energy distribution installations.
  • Large facilities requiring 6300 A circuit protection.
  • Withdrawable switchboards requiring high-performance LI protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2
Performance level H
Model / configuration E6.2H 6300 Ekip Dip LI 3p WMP
ABB order code 1SDA072641R1
Product type Air circuit breaker moving part
Current type AC
Rated uninterrupted current (Iu) 6300 A
Number of poles 3
Trip unit Ekip Dip LI
Trip unit type Solid-state electronic
Protection functions Long-time and instantaneous (LI)
Long-time protection L
Instantaneous protection I
Integrated short-time protection No
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Execution Withdrawable moving part (WMP)
Fixed part Separate matching Emax 2 fixed part required
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072641R1?

The ABB 1SDA072641R1 is a SACE Emax 2 E6.2H 6300 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LI solid-state electronic trip unit.

What is the rated current of the ABB 1SDA072641R1?

The breaker has a rated uninterrupted current of 6300 A, making it suitable for exceptionally high-current low-voltage AC power distribution circuits.

What protection functions does the Ekip Dip LI trip unit provide?

The LI configuration provides long-time overload protection and instantaneous short-circuit protection. It does not incorporate the short-time or earth-fault functions found in LSI and LSIG configurations.

What is the short-circuit performance of the E6.2H 6300?

The E6.2H 6300 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

What does WMP mean on the ABB E6.2H 6300?

WMP identifies the withdrawable moving-part execution. The breaker moving part is designed for use with a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.

Trusted Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high current-carrying capability, substantial short-circuit performance, dependable electronic protection and flexible withdrawable architecture for demanding industrial, commercial and infrastructure power distribution systems.