1SDA072616R1 ABB E6.2H 5000 Ekip Touch LSIG 3P WMP Air Circuit Breaker

1SDA072616R1 ABB E6.2H 5000 Ekip Touch LSIG 3P WMP Air Circuit Breaker

ABB 1SDA072616R1 SACE Emax 2 E6.2H 5000 A three-pole withdrawable air circuit breaker moving part with an Ekip Touch LSIG electronic trip unit for comprehensive high-current low-voltage AC distribution protection.

SKU: 1SDA072616R1MPN: 1SDA072616R1
Price
List Price £34,009.39 ex VAT
Your Price (ex VAT) Save 25%
£25,507.04 25% OFF
You save £8,502.35 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £25,507.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£25,507.04

Why Choose the ABB 1SDA072616R1 E6.2H 5000 Ekip Touch LSIG Air Circuit Breaker?

The ABB 1SDA072616R1 is a high-current SACE Emax 2 E6.2H 5000 air circuit breaker moving part designed for comprehensive protection and switching in demanding low-voltage AC power distribution systems. Configured as an E6.2H 5000 Ekip Touch LSIG 3p WMP, it combines a 5000 A rated uninterrupted current, three-pole construction and ABB's Ekip Touch electronic trip unit with comprehensive LSIG protection functions.

The E6.2H frame provides substantial short-circuit performance for major industrial, commercial and infrastructure distribution systems. This 5000 A H-performance configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s, supporting networks with very high prospective fault currents.

The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, with touchscreen-based programming for convenient protection configuration. Its three-pole withdrawable moving-part (WMP) architecture is designed for use with the appropriate Emax 2 fixed part, supporting isolation, inspection, servicing and replacement within critical switchboard installations.

Key Advantages

  • High-current ABB SACE Emax 2 E6.2H air circuit breaker moving part.
  • 5000 A rated uninterrupted current for major low-voltage power distribution circuits.
  • Ekip Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and earth-fault protection.
  • Short-time protection supports selective coordination between upstream and downstream protective devices.
  • Integrated earth-fault protection adds protection against potentially damaging ground-fault conditions.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding high-current distribution architectures.
  • Touchscreen interface supports convenient programming and management of protection settings.
  • Three-pole withdrawable construction supports efficient isolation, servicing and switchboard maintenance.

Key Features

  • ABB SACE Emax 2 E6.2 frame.
  • H short-circuit performance level.
  • 5000 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip Touch LSIG electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Earth-fault (G) protection.
  • Touchscreen programming interface.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • 690 V rated voltage.
  • Four auxiliary changeover contacts.
  • Circuit-breaker open/closed position indication.
  • Optional motor drive capability.
  • IP30 degree of protection.
  • Withdrawable moving-part (WMP) execution.

Comprehensive LSIG Protection for Critical High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage networks against overload, short-circuit and earth-fault conditions. With a 5000 A rated uninterrupted current, 100 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA short-time withstand capability for 1 s, the 1SDA072616R1 is engineered for critical distribution points requiring substantial current-carrying and fault-management capability.

The Ekip Touch LSIG trip unit provides four complementary protection functions. Long-time protection responds to sustained overloads, short-time protection supports selective coordination, instantaneous protection rapidly interrupts severe short circuits, and earth-fault protection responds to fault current flowing through unintended paths to earth. Combined with touchscreen programming and the E6.2H withdrawable architecture, this configuration provides comprehensive protection and practical maintainability for sophisticated high-current distribution systems.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial plants with high prospective short-circuit currents.
  • Transformer secondary protection.
  • High-current distribution feeder protection.
  • Data centres and critical-power installations.
  • Large commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Utility and energy distribution installations.
  • Systems requiring selective coordination and integrated earth-fault protection.
  • Withdrawable switchboards requiring comprehensive LSIG protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2
Performance level H
Model / configuration E6.2H 5000 Ekip Touch LSIG 3p WMP
ABB order code 1SDA072616R1
Product type Air circuit breaker moving part
Current type AC
Rated uninterrupted current (Iu) 5000 A
Rated voltage 690 V
Number of poles 3
Trip unit Ekip Touch LSIG
Trip unit type Electronic
Protection functions Long-time, short-time, instantaneous and earth-fault (LSIG)
Long-time protection L
Short-time protection S
Instantaneous protection I
Integrated earth-fault protection Yes
Overload release setting 2000–5000 A
Short-time delayed short-circuit setting 1.5–15 × In
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Auxiliary changeover contacts 4
Circuit-breaker position indication Open / closed
Integrated undervoltage release No
Motor drive Optional
Integrated motor drive No
Degree of protection IP30
Main-circuit connection Connection at separate chassis part
Control element Push button
Protection unit Included
DIN rail mounting No
Execution Withdrawable moving part (WMP)
Fixed part Separate matching Emax 2 fixed part required
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072616R1?

The ABB 1SDA072616R1 is a SACE Emax 2 E6.2H 5000 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LSIG electronic trip unit.

What is the rated current of the ABB 1SDA072616R1?

The breaker has a rated uninterrupted current of 5000 A, making it suitable for major high-current low-voltage AC power distribution circuits.

What protection functions does the Ekip Touch LSIG trip unit provide?

The LSIG configuration provides long-time overload, short-time short-circuit, instantaneous short-circuit and integrated earth-fault protection, providing comprehensive protection for high-current distribution networks.

What is the short-circuit performance of the E6.2H 5000?

The E6.2H 5000 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

What does WMP mean on the ABB E6.2H 5000?

WMP identifies the withdrawable moving-part execution. The breaker moving part connects to a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.

Trusted Comprehensive Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic LSIG protection and flexible withdrawable architecture for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure systems.