1SDA072615R1 ABB E6.2H 5000 Ekip Touch LSI 3P WMP Air Circuit Breaker

1SDA072615R1 ABB E6.2H 5000 Ekip Touch LSI 3P WMP Air Circuit Breaker

ABB 1SDA072615R1 SACE Emax 2 E6.2H 5000 A three-pole withdrawable air circuit breaker moving part with an Ekip Touch LSI electronic trip unit for advanced selective high-current low-voltage AC distribution protection.

SKU: 1SDA072615R1MPN: 1SDA072615R1
Price
List Price £33,288.31 ex VAT
Your Price (ex VAT) Save 25%
£24,966.23 25% OFF
You save £8,322.08 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,966.23
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,966.23

Why Choose the ABB 1SDA072615R1 E6.2H 5000 Ekip Touch LSI Air Circuit Breaker?

The ABB 1SDA072615R1 is a high-current SACE Emax 2 E6.2H 5000 air circuit breaker moving part designed for protection and switching in demanding low-voltage AC power distribution systems. Configured as an E6.2H 5000 Ekip Touch LSI 3p WMP, it combines a 5000 A rated uninterrupted current, three-pole construction and ABB's Ekip Touch electronic trip unit with LSI protection functions.

The E6.2H frame provides substantial short-circuit performance for major industrial and infrastructure distribution systems. At the 5000 A rating, this configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s, supporting installations with very high prospective fault currents.

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, with a touchscreen interface for protection configuration and operating information. Its three-pole withdrawable moving-part (WMP) architecture connects to a separate matching Emax 2 fixed part, supporting isolation, inspection, servicing and replacement within critical switchboard installations.

Key Advantages

  • High-current ABB SACE Emax 2 E6.2H air circuit breaker moving part.
  • 5000 A rated uninterrupted current for major low-voltage distribution circuits.
  • Ekip Touch LSI electronic trip unit provides advanced overload and short-circuit protection.
  • Short-time protection supports selective coordination between upstream and downstream protective devices.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA short-time withstand current for 1 s supports demanding high-current distribution architectures.
  • Touchscreen interface provides convenient access to protection settings and operating information.
  • Three-pole withdrawable construction supports efficient isolation, servicing and switchboard maintenance.
  • Four auxiliary changeover contacts support breaker-status signalling and control integration.

Key Features

  • ABB SACE Emax 2 E6.2 frame.
  • H short-circuit performance level.
  • 5000 A rated uninterrupted current.
  • Three-pole construction.
  • Ekip Touch LSI electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Touchscreen interface for protection configuration and operating information.
  • 100 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • 690 V AC rated operational voltage.
  • Four auxiliary changeover contacts.
  • Switched-off indication.
  • Optional motor drive capability.
  • IP30 degree of protection.
  • Withdrawable moving-part (WMP) execution.

Advanced Selective Protection for High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2H protect major low-voltage networks against overload and short-circuit conditions. With a 5000 A rated uninterrupted current, 100 kA ultimate short-circuit breaking capacity at 440 V AC and 100 kA short-time withstand capability for 1 s, the 1SDA072615R1 is engineered for critical distribution points where substantial current-carrying and fault-management capability is required.

The Ekip Touch LSI trip unit provides three complementary protection functions. Long-time protection responds to sustained overloads, short-time protection provides a delayed short-circuit stage that can assist selective coordination with downstream protection, and instantaneous protection rapidly interrupts severe short circuits. Combined with the E6.2H frame, touchscreen trip-unit platform and withdrawable architecture, this configuration provides a robust and maintainable solution for sophisticated high-current distribution systems.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial plants with high prospective short-circuit currents.
  • Transformer secondary protection.
  • High-current distribution feeder protection.
  • Data centres and critical-power installations.
  • Large commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Utility and energy distribution installations.
  • Systems requiring selective coordination between upstream and downstream protection.
  • Withdrawable switchboards requiring advanced LSI protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2
Performance level H
Model / configuration E6.2H 5000 Ekip Touch LSI 3p WMP
ABB order code 1SDA072615R1
Product type Air circuit breaker moving part
Current type AC
Rated uninterrupted current (Iu) 5000 A
Rated operational voltage 690 V AC
Number of poles 3
Trip unit Ekip Touch LSI
Trip unit type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection L
Short-time protection S
Instantaneous protection I
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Auxiliary changeover contacts 4
Switched-off indication Yes
Integrated undervoltage release No
Motor drive Optional
Integrated motor drive No
Degree of protection IP30
Main-circuit connection Connection at separate chassis part
Control element Push button
Protection unit Included
Power loss 850 W
EAN 8015644764654
Execution Withdrawable moving part (WMP)
Fixed part Separate matching Emax 2 fixed part required
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072615R1?

The ABB 1SDA072615R1 is a SACE Emax 2 E6.2H 5000 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Touch LSI electronic trip unit.

What is the rated current of the ABB 1SDA072615R1?

The breaker has a rated uninterrupted current of 5000 A, making it suitable for major high-current low-voltage AC power distribution circuits.

What protection functions does the Ekip Touch LSI trip unit provide?

The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function helps support selective coordination with downstream protective devices.

What is the short-circuit performance of the E6.2H 5000?

The E6.2H 5000 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

What does WMP mean on the ABB E6.2H 5000?

WMP identifies the withdrawable moving-part execution. The breaker moving part connects to a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.

Trusted Selective Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection and flexible withdrawable architecture for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure systems.