Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072612R1 is a SACE Emax 2 E6.2H 5000 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI electronic trip unit for selective high-current low-voltage power distribution protection.
£24,902.22
The ABB 1SDA072612R1 is a high-performance SACE Emax 2 E6.2H 5000 air circuit breaker moving part designed for demanding high-current low-voltage power distribution systems. This three-pole configuration combines a 5000 A rated uninterrupted current with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
As part of the ABB SACE Emax 2 range, the E6.2H is engineered for installations requiring substantial current capacity, high short-circuit performance and selective protection. The Ekip Dip LSI release provides adjustable electronic protection for overload and short-circuit conditions, making this breaker suitable for main incomers, high-current feeders and other critical distribution circuits.
This model is a 3-pole withdrawable moving part (WMP) rated at 5000 A and 690 V AC. The E6.2H performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 100 kA at 690 V AC, supporting demanding switchboards with high prospective fault currents.
Air circuit breakers such as the ABB SACE Emax 2 E6.2H provide switching and protection for very high-current low-voltage distribution circuits. The Ekip Dip electronic release monitors circuit conditions and initiates interruption when configured protection thresholds are exceeded, helping protect switchgear, conductors and connected equipment against overload and short-circuit currents.
The Ekip Dip LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit protection. Together with the E6.2H frame's 100 kA short-circuit breaking capability, 5000 A current rating and withdrawable architecture, the 1SDA072612R1 provides a robust solution for high-capacity installations where selective protection, dependable performance and maintainability are essential.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA072612R1 |
| EAN | 8015644764623 |
| Product type | Air circuit breaker moving part |
| Frame | E6.2H |
| Performance level | H |
| Rated current (In) | 5000 A |
| Rated uninterrupted current (Iu) | 5000 A |
| Number of poles | 3 |
| Trip unit | Ekip Dip LSI |
| Release technology | Solid-state electronic |
| Protection functions | L, S and I |
| Overload release current setting | From 2000 A |
| Short-time delayed short-circuit release setting | From 3000 A |
| Instantaneous short-circuit release setting | From 7500 A |
| Integrated earth-fault protection | No |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Electrical durability at ≤440 V | 3000 cycles |
| Electrical durability at 500–690 V | 2000 cycles |
| Mechanical durability | 12,000 cycles |
| Power loss | 850 W |
| Auxiliary contacts | 4 change-over contacts |
| Switched-off indicator | Yes |
| Motor drive integrated | No |
| Motor drive | Optional |
| Degree of protection | IP30 |
| Main-circuit connection | Connection at separate chassis part |
| Configuration | Withdrawable moving part (WMP) |
| Product net depth | 383 mm |
| Product net weight | 120 kg |
| Standard | IEC 60947-2 |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA072612R1 is a SACE Emax 2 E6.2H 5000 A three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI electronic trip unit.
The ABB 1SDA072612R1 has a rated uninterrupted current of 5000 A, making it suitable for very high-current low-voltage distribution systems.
The Ekip Dip LSI provides L long-time overload, S short-time delayed short-circuit and I instantaneous short-circuit protection.
The E6.2H 5000 configuration provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 100 kA at 690 V AC.
The breaker provides an overload release setting from 2000 A, a short-time delayed short-circuit release setting from 3000 A, and an instantaneous short-circuit release setting from 7500 A.
No. This model uses an Ekip Dip LSI release providing long-time, short-time and instantaneous protection; integrated earth-fault protection is not included in this configuration.
This model is supplied as a withdrawable moving part (WMP), with the main circuit connected through the appropriate separate SACE Emax 2 fixed chassis part.
The ABB 1SDA072612R1 is equipped with 4 auxiliary change-over contacts and provides switched-off indication.
ABB SACE Emax 2 air circuit breakers are designed for demanding low-voltage power distribution systems where dependable electronic protection, high short-circuit performance and maintainable switchgear architecture are required.