1SDA072592R1 ABB E6.2V 4000 Ekip Dip LSI 3P WMP Air Circuit Breaker

1SDA072592R1 ABB E6.2V 4000 Ekip Dip LSI 3P WMP Air Circuit Breaker

ABB 1SDA072592R1 SACE Emax 2 E6.2V 4000 A three-pole withdrawable air circuit breaker moving part with an Ekip Dip LSI electronic trip unit for selective high-current low-voltage AC distribution protection.

SKU: 1SDA072592R1MPN: 1SDA072592R1
Price
List Price £32,124.29 ex VAT
Your Price (ex VAT) Save 25%
£24,093.22 25% OFF
You save £8,031.07 per unit
Manufacturer Lead Time Estimated Delivery 6 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £24,093.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£24,093.22

Why Choose the ABB 1SDA072592R1 E6.2V 4000 Ekip Dip LSI Air Circuit Breaker?

The ABB 1SDA072592R1 is a high-performance SACE Emax 2 E6.2V 4000 air circuit breaker moving part designed for protection and switching in demanding high-current low-voltage AC power distribution systems. Configured as an E6.2V 4000 Ekip Dip LSI 3p WMP, it combines a 4000 A rated current, three-pole construction and ABB's Ekip Dip electronic trip unit with LSI protection functions.

The E6.2V is a very-high-performance configuration within the ABB SACE Emax 2 family. This 4000 A model provides an ultimate short-circuit breaking capacity of 150 kA at 415 V AC and 100 kA at 690 V AC, providing the fault-interruption capability required for major distribution points with exceptionally high prospective short-circuit currents.

The Ekip Dip LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The addition of short-time protection supports selective coordination with downstream protective devices, while the three-pole withdrawable moving-part (WMP) architecture enables the breaker to be isolated and withdrawn from its separately ordered fixed part for inspection, maintenance or replacement.

Key Advantages

  • High-performance ABB SACE Emax 2 E6.2V air circuit breaker moving part.
  • 4000 A rated current for major low-voltage power distribution circuits.
  • Ekip Dip LSI electronic trip unit provides overload and two-stage short-circuit protection.
  • Short-time protection supports selective coordination with downstream protective devices.
  • 150 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 100 kA ultimate short-circuit breaking capacity at 690 V AC.
  • Four auxiliary contacts and a trip signalling contact are supplied as standard on the withdrawable breaker configuration.
  • Three-pole withdrawable construction supports efficient isolation, inspection and switchboard maintenance.
  • Suitable for main incomers, transformer secondaries and high-current distribution feeders.

Key Features

  • ABB SACE Emax 2 E6.2 frame.
  • V high short-circuit performance level.
  • 4000 A rated current.
  • Three-pole construction.
  • Ekip Dip LSI electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • 150 kA Icu at 415 V AC.
  • 100 kA Icu at 690 V AC.
  • Four auxiliary contacts (4Q).
  • Trip signalling contact (S51).
  • Withdrawable moving-part (WMP) execution.
  • Separate fixed part required for complete withdrawable installation.
  • Compatible fixed-part rear terminals can be configured for horizontal or vertical orientation.

Selective LSI Protection for Critical High-Current Distribution

Air circuit breakers such as the ABB Emax 2 E6.2V protect major low-voltage networks against overload and short-circuit conditions. With a 4000 A rated current and an ultimate short-circuit breaking capacity reaching 150 kA at 415 V AC, the 1SDA072592R1 is particularly suited to critical distribution points where very high prospective fault currents can occur.

The Ekip Dip LSI trip unit provides three complementary electronic protection functions. Long-time protection responds to sustained overloads, short-time protection introduces an adjustable short-circuit protection stage that can assist selectivity with downstream devices, and instantaneous protection rapidly interrupts severe short circuits. Combined with the E6.2V frame and withdrawable architecture, this provides a robust and maintainable solution for sophisticated high-current distribution systems.

Typical Applications

  • Main incoming protection in high-current low-voltage switchboards.
  • Industrial plants with very high prospective short-circuit currents.
  • Transformer secondary protection.
  • High-current distribution feeder protection.
  • Data centres and critical-power installations.
  • Large commercial and infrastructure electrical distribution.
  • Manufacturing and process-industry switchgear.
  • Utility and energy distribution installations.
  • Systems requiring selective coordination between upstream and downstream protection.
  • Withdrawable switchboards requiring high-performance LSI protection.

Technical Specifications

Series SACE Emax 2
Frame E6.2
Performance level V
Model / configuration E6.2V 4000 Ekip Dip LSI 3p WMP
ABB order code 1SDA072592R1
Extended ABB order code 1SDA072592R0001
Product type Air circuit breaker moving part
Current type AC
Rated current 4000 A
Number of poles 3
Trip unit Ekip Dip LSI
Trip unit type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection L
Short-time protection S
Instantaneous protection I
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 150 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 100 kA
Auxiliary contacts 4Q
Trip signalling contact S51
Execution Withdrawable moving part (WMP)
Fixed part Ordered separately
Fixed-part terminal arrangement Rear terminals configurable horizontally or vertically on compatible fixed part
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA072592R1?

The ABB 1SDA072592R1 is a SACE Emax 2 E6.2V 4000 three-pole withdrawable air circuit breaker moving part equipped with an Ekip Dip LSI electronic trip unit.

What is the rated current of the ABB 1SDA072592R1?

The breaker has a rated current of 4000 A, making it suitable for major high-current low-voltage AC power distribution circuits.

What protection functions does the Ekip Dip LSI trip unit provide?

The LSI configuration provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. The short-time function is particularly useful for coordinating upstream and downstream protective devices.

What is the breaking capacity of the E6.2V 4000?

The E6.2V 4000 provides a rated ultimate short-circuit breaking capacity of 150 kA at 415 V AC and 100 kA at 690 V AC, making it suitable for networks with exceptionally high prospective fault currents.

What does WMP mean on the ABB E6.2V 4000?

WMP identifies the withdrawable moving-part execution. The breaker moving part is installed with a separate matching Emax 2 fixed part and can be withdrawn to support isolation, inspection, servicing and replacement.

Trusted Selective Protection for High-Current Power Systems

ABB SACE Emax 2 air circuit breakers combine exceptional short-circuit performance, selective electronic protection and flexible withdrawable architecture for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure systems.