Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA072582R1 SACE Emax 2 E6.2H 4000 A three-pole withdrawable air circuit breaker mobile part with Ekip Dip LSI protection, 690 V AC rated operational voltage and 100 kA short-circuit breaking capacity.
£20,215.50
The ABB 1SDA072582R1 is a high-performance SACE Emax 2 E6.2H air circuit breaker (ACB) designed for reliable protection of demanding low-voltage electrical distribution systems. Rated at 4000 A, this three-pole breaker combines ABB’s high-capacity E6.2H frame with an Ekip Dip LSI electronic trip unit providing long-time, short-time and instantaneous protection.
As part of the advanced ABB SACE Emax 2 air circuit breaker series, the E6.2H is engineered for high-current industrial switchboards, infrastructure, data centres, commercial installations and critical power distribution. Its Ekip Dip electronic release provides adjustable protection functions for effective coordination with downstream equipment while maintaining straightforward operation and configuration.
The 1SDA072582R1 is a three-pole withdrawable mobile part (WMP) with a rated uninterrupted current of 4000 A and rated operational voltage of 690 V AC. The E6.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA across key industrial voltages up to 690 V AC and a rated short-time withstand current of 100 kA for 1 second, making it suitable for installations with exceptionally high prospective fault currents.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage electrical systems against potentially damaging overload and short-circuit conditions. The E6.2 frame is designed for large distribution systems, while the H performance level delivers high short-circuit interruption and withstand capability for installations with substantial prospective fault currents.
The Ekip Dip LSI electronic trip unit provides adjustable long-time overload, short-time delayed and instantaneous short-circuit protection. This combination enables effective protection coordination and selectivity within complex distribution networks, while the withdrawable Emax 2 architecture simplifies isolation and maintenance in critical switchboard applications.
| Series | SACE Emax 2 |
|---|---|
| Frame | E6.2 |
| Order code / SKU | 1SDA072582R1 |
| EAN | 8015644764326 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Current type | AC |
| Performance level | H |
| Trip unit | Ekip Dip |
| Protection functions | LSI |
| Overload release adjustment range | 1600–4000 A |
| Short-time delayed short-circuit adjustment range | 2400–40000 A |
| Instantaneous short-circuit adjustment range | 6000–60000 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Rated short-time withstand current (Icw, 1 s) | 100 kA |
| Rated short-time withstand current (Icw, 3 s) | 100 kA |
| Integrated earth-fault protection | No |
| Execution | Withdrawable mobile part |
| Main circuit connection | Connection through separate fixed part |
| Auxiliary change-over contacts | 4 |
| Operating element | Push button |
| Motor operator | Optional |
| Protection rating | IP30 |
| Power loss | 544 W |
| Mechanical durability | 12000 operations |
| Dimensions (H × W × D) | 425 × 803 × 383 mm |
| Standard | IEC 60947-2 |
The ABB 1SDA072582R1 is a three-pole SACE Emax 2 E6.2H withdrawable air circuit breaker mobile part rated at 4000 A and equipped with an Ekip Dip LSI electronic trip unit.
The breaker has a rated uninterrupted current of 4000 A and a rated operational voltage of 690 V AC.
The E6.2H provides an ultimate short-circuit breaking capacity of 100 kA at key industrial voltages from 400 V AC through 690 V AC, together with a rated short-time withstand current of 100 kA for 1 second.
Ekip Dip is ABB’s electronic protection trip unit, while LSI denotes long-time, short-time and instantaneous protection. This configuration provides adjustable overload and short-circuit protection without integrated earth-fault protection.
The 1SDA072582R1 is a withdrawable mobile part designed for connection through the appropriate Emax 2 fixed part, allowing the breaker to be isolated and withdrawn from the switchboard for inspection, servicing and maintenance.
ABB SACE Emax 2 air circuit breakers combine high-current circuit protection, high short-circuit performance and flexible withdrawable switchboard integration for demanding industrial, infrastructure and critical low-voltage electrical distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.